Apparecchiature Elettriche Assiemate per Cantieri EdiliApparecchiature Elettriche Assiemate per Cantieri EdiliApparecchiature Elettriche Assiemate per Cantieri EdiliApparecchiature Elettriche Assiemate per Cantieri Edili
NNNooorrrmmmeee dddiii rrriiissspppeeettttttooo ::: MMMaaarrrccchhhiiiooo IIIMMMQQQ(((sssuuu ppprrreeessseee iiinnnttteeerrrbbbllloooccccccaaattteee eee iiinnnttteeerrrrrruuuttttttooorrriii mmmaaagggnnneeetttooottteeerrrmmmiiiccciii)));;; MMMaaarrrcccaaatttuuurrraaa CCCEEE(((sssuuu tttuuutttttt iii iii ppprrrooodddoootttttt iii)));;; CCCEEEIII 111777---111333///444 EEENNN 666000444333999///444 CCCEEEIII 111777---111333///111///444(((QQQuuuaaadddrrriii CCCaaannnttt iiieeerrreee eee CCCaaammmpppeeeggggggiiiooo)));;;
EEENNN 666000999444777---444---AAA111(((SSSaaalllvvvaaammmoootttooorrriii)));;; CCCEEEIII 111444---111666(((TTTrrraaasssfffooorrrmmmaaatttooorrriii)));;; CCCEEEIII 111333111666(((AAAvvvvvvooolllgggiiicccaaavvvooo))) ;;;
CCCEEEIII 666444---888VVV777 (((PPPrrrooollluuunnnggghhheee pppeeerrr cccaaannnttt iiieeerrreee)));;; CCCEEEIII 333444---222111 eee 333444---222333 (((LLLuuuccciii pppeeerrr pppooonnnttteeeggggggiii)));;;
NNNOOORRRMMMAAA
EEEUUURRROOOPPPEEEAAA
EEENNN 666000444333999---444
ASCASCASCASC Apparecchiature Assiema te per Cant iere
Catalogo Generale
MARZO 2013
Oltre Oltre Oltre Oltre 30303030 Anni di esperienza nel settore a servizio del Cliente Anni di esperienza nel settore a servizio del Cliente Anni di esperienza nel settore a servizio del Cliente Anni di esperienza nel settore a servizio del Cliente
Sede Unica : Via S.Francesco D’Assisi,8 , 70026 - Modugno ( BA )
Tel. 080 / 5326254 – 080/5326478 - Fax. 080 / 5326254 http://www.smeisas.com
e-mail: smei-italy@tiscali.it – smei_sas@libero.it
SOCIETA’ MERIDIONALE PER L’ELETTROTECNICA E
L’ELETTRONICA INDUSTRIALE
2
SOMMARIO: Informazioni Utili e Norme Tecniche di riferimento Pag.3 Quadri Elettrici Sottocontatori – Serie CONTATOR BOX Pag.6 Quadri Generali di Distribuzione – Serie GENERAL BOX Pag.7 Quadri Elettrici di Distribuzione Finale – Serie MAXIBOX ULTRA Pag.8 Quadri Elettrici di Distribuzione Finale – Serie MINIBOX CLASSIC Pag.9 Quadri Elettrici di Distribuzione Finale – Serie MEDIUMBOX Pag.10 Quadri Elettrici di Distribuzione Finale – Serie BELBOX MASTER Pag.11 Quadri Elettrici Portatili – Serie PORTABLE BOX da 3 a 8 prese Pag.12 – 16 Quadri Elettrici Trasportabili con prese interbloccate – PORTABLE BOX da 2 a 4 prese Pag.17 – 19 Quadri Elettrici su rullo avvolgicavo – Serie Roller Box Pag.20 Avvolgicavo Industriale – Serie Medium Roller Pag.21 Avvolgicavo Industriale su ruote – Serie Maxi Roller Pag.22 Avvolgicavo Bricolage – Serie Mini Roller Pag.23 Trasformatori per Luci Ponteggi 230/24V – Serie Trasformer Box Pag.23 Illuminazione per ponteggi 24V – Serie LP Pag.24 Led Stradali o per illuminazione ponteggi con batteria – Serie Led Street Pag.24 Adattatori Industriali per usi temporanei – Serie AD Pag.25 Proiettori e Lampade per cantieri – Serie PAL - LAM Pag.26 Salvamotori per macchine Edili – Serie SM Pag.27 Cavi e prolunghe industriali – Serie CVN – PLN Pag.28 Partitori di Tensione per uso temporaneo – Serie PA Pag.29 Spine e prese Industriali – Serie SP - PR Pag.30 Spine e prese Civili – Serie SPC - PRC Pag.31 Adattatori Civili – Serie ADC Pag.31 Prese Multiple Civili – Serie PM Pag.32 Ricambi – Interruttori Modulari, pulsanti, salvamotori, lampade, microplafoniere Pag.33 Condizioni Generali di vendita Pag.36
3
INFORMAZIONI UTILI Le Direttive CE
I prodotti inseriti nel presente catalogo rispondono senza eccezioni ai requisiti imposti dalle Direttive europee applicabili.Le Direttive più importanti nel Settore Elettrico sono: · Direttiva Macchine MD 89/392; · Direttiva Compatibilità Elettromagnetica EMC 89/336; · Direttiva Bassa Tensione LVD 73/23 e 93/68. Scopo delle Direttive Comunitarie è di favorire la libera circolazione delle merci all'interno del territorio CE richiedono la rispondenza alle Norme specifiche armonizzate o, in mancanza di queste, alle norme nazionali.
NORME DI RIFERIMENTO RELATIVE
ALLE DIRETTIVE COMUNITARIE
Linea prodotto Direttiva BT Pulsanti EN 60947-5-1, VDE 0630 Relè elettromeccanici IEC 255, VDE 0435 Relè statici EN 60950, IEC 947-4-2, IEC 947-4-3 Quadri ASC per cantiere EN 60439-4 Trasformatori EN 60742-4 Avvolgicavo IEC 13-16 Salvamotori EN 60947-4-1, EN60947-4-1/A1 Spine e prese EN 60309-1, EN 60309-2
Scelta dei cavi Per la realizzazione degli impianti nei cantieri si possono adottare i seguenti tipi di cavi (conduttori in rame):
FROR 450/750 V cavo multipolare, con isolamento in pvc, per posa fissa; FG7R 0,6/1kV cavo unipolare o multipolare, isolato in gomma (G7) con guaina FG7OR 0,6/1/kV pvc, per posa fissa, adatto anche per posa interrata; H07RN-F cavo unipolare o multipolare, isolato in gomma (G) sotto guaina esterna in policroroprene (commercialmente denominato "neoprene"), resistente all'acqua e all'abrasione, per posa mobile;H07BQ-F cavo multipolare, isolato in EPR e guaina in poliuretano, resistente 450/750V all'acqua e all'abrasione, per posa mobile.Si intendono per posa fissa i cavi destinati a non essere spostati durante la vita del cantiere, ad esempio nel tratto che va dal contatore di energia elettrica al quadro generale. I cavi per posa mobile sono invece soggetti a spostamenti (cavi per uso mobile), ad esempio il cavo che alimenta il quadro prese a spina o un apparecchio trasportabile Vale la pena sottolineare che per cavi flessibili, propriamente detti, si intendono i cavi per posa mobile, ad esempio H07RN-F; tali cavi non vanno confusi con i cavi per posa fissa con conduttore flessibile, ad esempio H07V-K, i quali sono anche chiamati "flessibili" nel gergo comune, il che genera non poca confusione.
· Protezione delle prese a spina I contatti diretti nei cantieri avvengono prevalentemente sui cavi flessibili di alimentazione degli apparecchi, e dunque a valle, in genere di una presa a spina. Le prese a spina fino a 32A devono essere protette da interruttori differenziali con Idn = 30mA, i quali costituiscono anche una protezione addizionale contro i contatti diretti.
· Comandi di emergenza Il comando di emergenza ha lo scopo di interrompere rapidamente l'alimentazione all'intero impianto elettrico, o a una sua parte, in caso di pericoli imprevisti: esso deve essere pertanto noto a tutte le maestranze, facilmente raggiungibile ed individuabile. In un cantiere è opportuno predisporre un comando di emergenza sul quadro generale e sui quadri secondari (di zona). A tal fine si può anche utilizzare l'interruttore generale del quadro (non chiudibile a chiave), ma in questo caso l'interruttore generale andrà individuato con apposita targa. Nei quadri chiudibili a chiave non è possibile utilizzare l'interruttore generale come comando di emergenza, perché questo deve essere prontamente accessibile. Il comando di emergenza può essere allora costituito da un pulsante a fungo, di colore rosso su fondo di contrasto, ad esempio giallo, che agisce sull'interruttore generale, posizionato all'esterno del quadro.
4
· Prese interbloccate L'interblocco tra presa a spina e interruttore evita pericoli per l'operatore che inserisca la spina in condizioni di cortocircuito a valle della spina stessa. Il pericolo reale è quando le correnti di cortocircuito superano il valore di 5-6 kA e il circuito non è protetto da fusibili o interruttori limitatori di corrente. La presa interbloccata può essere quindi necessaria nei grandi cantieri con potenza impegnata maggiore di 30 kW, o nei cantieri con propria cabina di trasformazione. Per ragioni pratiche, dovendo predisporre uno o più tipologie di quadri per cantiere, molti preferiscono utilizzare in modo sistematico le prese a spina interbloccate, non conoscendo a priori il cantiere in cui il quadro sarà utilizzato.
· Prese sull'avvolgicavo La norma ammette l'utilizzo di prese incorporate in avvolgicavo. I cavi devono essere del tipo H07RN-F o equivalente. Gli avvolgicavo devono essere dotati di protezione incorporata contro le sovracorrenti o di protezione termica; il dispositivo sul quadro potrebbe, infatti, non essere adatto a proteggere il cavo dell'avvolgicavo stesso, specie se il cavo è avvolto. L'avvolgicavo è utilizzato nei luoghi più disparati (scantinati, in prossimità di pozzanghere, luoghi soggetti a getti d'acqua, ecc.), è quindi raccomandabile che la presa a spina abbia un grado di protezione IP67.
· Quadri elettrici La norma CEI 17-13/1, distingue i quadri elettrici AS (Apparecchiature in Serie) e ANS (Apparecchiature Non in Serie). I quadri AS e ANS differiscono tra loro soprattutto per le prove a cui devono essere sottoposti. Nei cantieri sono ammessi solo quadri elettrici costruiti in serie (AS). I quadri per i cantieri sono denominati ASC (Apparecchiature di Serie per Cantierie); per i quadri ASC sono previste prove aggiuntive di resistenza meccanica e alla corrosione. Ogni quadro elettrico per cantiere deve essere munito di una targa indelebile, apposta dal costruttore, ove siano riportati in modo visibile e leggibile i seguenti dati: il nome o marchio di fabbrica del costruttore; il tipo, o numero di identificazione, o altro mezzo che renda possibile ottenere dal costruttore tutte le informazioni necessarie; EN 60439-4; natura e valore nominale della corrente del quadro e la frequenza per la corrente alternata; tensioni di funzionamento nominali. Si possono utilizzare soltanto quadri elettrici dichiarati dal costruttore ASC di cantiere, conformi alla norma CEI 17-13/4. La norma CEI 23-51 non è applicabile ai quadri per cantiere.
· Illuminazione Gli apparecchi di illuminazione possono essere soggetti a spruzzi, o a essere investiti da getti d'acqua, ad esempio nel bagnare i muri prima dell'intonacatura; è opportuno quindi che abbiano un grado di protezione almeno IP55. L'illuminazione ordinaria nel cantiere può essere attuata con apparecchi fissi, trasportabili o portatili. Gli apparecchi di illuminazione fissi possono essere installati su pali, sul traliccio della gru, o in altre posizioni elevate. Nei cantieri di notevoli dimensioni anche i posti di lavoro ed i passaggi interni, specie lungo i vani scala, devono essere opportunamente illuminati. Se si utilizzano apparecchi trasportabili (su treppiedi, cavalletti, ecc.) quando si devono illuminare parti della costruzione in fase di finitura. Gli apparecchi di illuminazione trasportabili possono essere alimentati a 230V diretta mente dalla rete, oppure a 24V tramite trasformatore di sicurezza (SELV); le lampade utilizzate nei luoghi conduttori ristretti devono essere alimentate a bassissima tensione di sicurezza. Durante i lavori potrebbero crearsi situazioni di pericolo sulle vie di transito adiacenti al cantiere a causa di scavi, pozzetti, ponteggi sovrastanti i marciapiedi o ingombri di macchine (ad esempio basamenti di gru che invadono la sede stradale). Le situazioni di pericolo devono essere segnalate, generalmente con apparecchi di illuminazione di colore rosso. Se tali apparecchi sono posti a portata di mano (h = 2,5m), è opportuno utilizzare la bassissima tensione di sicurezza.
· Grado di protezione I quadri elettrici di cantiere devono avere un grado di protezione di almeno IP44. Il grado di protezione va inteso con l'entrata cavi effettuata a regola d'arte e con la porta chiusa se il quadro è previsto per funzionare con la porta chiusa. Il grado di protezione di un involucro è identificato, in sede IEC (International Electrotechnical Commission), dalle lettere IP (International Protection) seguito da due cifre ed eventualmente da una lettera. La prima cifra indica il grado di protezione contro la penetrazione all'interno dell'involucro di corpi solidi e contro il contatto delle persone con parti interne pericolose,la seconda cifra indica il grado di protezione dell'involucro contro l'ingresso dannoso dell'acqua, la lettera addizionale indica il grado di protezione delle persone contro i contatti diretti con parti in tensione poste all'interno dell'involucro; è da usare quando detta protezione sia superiore a quella indicata dalla prima cifra caratteristica.
5
PROVE E VERIFICHE ESEGUITE DALLA NOSTRA DITTA SUI QUADRI ASC nr. tipo di prova rif.norma a cura del 1 verifica dei limiti di sovratemperatura 8.2.1 assemblatore 2 verifica della tensione applicata 8.2.2 assemblatore 3 verifica di tenuta al corto circuito 8.2.3 assemblatore 4 verifica dell'efficienza del circuito di protezione 8.2.4 assemblatore
verifica di connessione tra le masse ed il circuito 8.2.4.1 assemblatore di protezione verifica di tenuta al cortocircuito del circuito 8.2.4.2 assemblatore di protezione
5 verifica delle distanze in aria e superficiali 8.2.5 assemblatore 6 verifica del funzionamento meccanico 8.2.6 assemblatore 7 grado di protezione IP 8.2.7 costruttore 8 resistenza meccanica 8.2.8 costruttore 9 resistenza alla corrosione 8.2.9 costruttore 10 prova del cablaggio e del funzionamento elettrico 8.3.1 assemblatore 11 prova di isolamento e tensione applicata 8.3.2 assemblatore 12 prova delle misure di protezione e della continuità 8.3.3 assemblatore
elettrica dei circuiti di protezione Le prove 1, 2, 3, 4, 5, 6 sono definite prove di tipo e vengono eseguite su prototipi a cura dell'assemblatore dell'apparecchiatura. Le prove 7, 8, 9 sono anch'esse prove di tipo e vengono eseguite dal costruttore. Le prove 10, 11, 12 sono prove individuali e vengono eseguite dall'assemblatore su ogni singola apparecchiatura. Per quanto riguarda le normative sulle sezioni dei cavetti di cablaggio, fa riferimento l'articolo 704 della normativa CEI 64/8
TARGA SU QUADRI ASC Ciascun Quadro Elettrico ASC della ditta S.M.E.I. è corredato di una o più targhe, marcate in maniera durevole e sistemate in modo che siano visibili e leggibili quando l’apparecchiatura è installata le seguenti informazioni: A) nome del costruttore o marchio di fabbrica del costruttore; B) designazione del tipo o numero di identificazione o altro mezzo di identificazione che renda possibile ottenere dal costruttore le informazioni pertinenti; C) EN 60439-4 ; D) natura e valore nominale della corrente dell’unita (e frequenza in caso di c.a.); E) tensioni di funzionamento (di impiego) nominali; F) tenuta al corto circuito; G) grado di protezione; H) condizioni di servizio per uso speciale, se diverse dalle condizioni normali di servizio indicate nella normativa (EN 60439-4); I) dimensioni; J) peso; DEFINIZIONE DI QUADRO ASC : Apparecchiatura costruita in serie per cantiere.Combinazione di una o più dispositivi di transazione o di chiusura e interruzione con le apparecchiature associate di comando, di misura , di segnalazione, di protezione e di regolazione, complete di tutte le loro connessioni elettriche e meccaniche e di tutte le loro parti strutturali, progettate e costruite, per l’uso in tutti i cantieri all’interno o all’esterno.
QUADRO ASC TRASPORTABILE O SEMIFISSO : Apparecchiatura destinata all’uso in un luogo in cui non è permanentemente fissata, la sua collocazione può variare durante il lavoro nello stesso cantiere.Quando questa apparecchiatura deve essere spostata deve necessariamente essere messa fuori tensione.
QUADRO ASC MOBILE : Apparecchiatura destinata all’uso mobile in cantiere,può essere spostata quando il lavoro nel cantiere avanza. Quando questa apparecchiatura deve essere spostata può non essere messa fuori tensione.
6
QQQUUUAAADDDRRRIII EEELLLEEETTTTTTRRRIIICCCIII GGGEEENNNEEERRRAAALLLIII DDDIII DDDIIISSSTTTRRRIIIBBBUUUZZZIIIOOONNNEEE
SSSEEERRRIIIEEE “““CCCOOONNNTTTAAATTTOOORRR BBBOOOXXX”””
Staffe di Fissaggio a muro Interruttore Differenzia le Magnetotermico Corredato di staffe di fissaggio classe AC con taratura del differenziale che ne permettono un facile 0,3A utile a garantire la selettività ancoraggio a parete. all’impianto.
Pressatavi ingresso & uscita L’ingresso e l’uscita dei cavi viene realizzata a mezzo di pressacavi .La misura dei pressacavi varia a seconda del diametro del cavo e dell’amperaggio dell’interruttore scelto.Le misure dei pressacavi possono spaziare dal PG 16 al PG 36.
CODICE
DIFFERENZIALE MAGNETOTERMICO CON Id=0,3A Potenza
Erogabile
Pul
sant
e E
mer
genz
a
ALIMENTAZIONE CORRENTE NOMINALE
POTERE D’INTERRUZIONE
QSCB55 3P+N 400V 100A 10 kA 55 KW NO
QSCB35 3P+N 400V 63A 6 kA 35 KW NO
QSCB22 3P+N 400V 40A 6 kA 22 KW NO
QSCB18 3P+N 400V 32A 6 kA 18 KW NO
QSCB10 3P+N 400V 16A 6 kA 10 KW NO
QSCB7,5 P+N 230V 40A 6 kA 7,5 KW NO
QSCB6 P+N 230V 32A 6 kA 6 KW NO
QSCB3 P+N 230V 16A 6 kA 3 KW NO
QSCB55/E 3P+N 400V 100A 10 kA 55 KW SI
QSCB35/E 3P+N 400V 63A 6 kA 35 KW SI
QSCB22/E 3P+N 400V 40A 6 kA 22 KW SI
QSCB18/E 3P+N 400V 32A 6 kA 18 KW SI
QSCB10/E 3P+N 400V 16A 6 kA 10 KW SI
QSCB7,5/E P+N 230V 40A 6 kA 7,5 KW SI
QSCB6/E P+N 230V 32A 6 kA 6 KW SI
QSCB3/E P+N 230V 16A 6 kA 3 KW SI
Quadri ASC Sottocontatore costruiti in serie secondo CEI 17/13/4 e EN 60439-4: I quadri da cantiere ASC della serie “CONTATOR BOX” sono esclusivamente indicati per la protezione del tratto del cavo che va da contatore Enel sino al primo quadro di distribuzione del cantiere di grandi dimensioni. Il grado di protezione del quadro a sportello chiuso è IP65. La serie “CONTATOR BOX” è ovviamente è realizzata con differenziali ovviamente con Id=0,3A in modo tale da garantire la selettività con i differenziali posti nei quadri di distribuzione.Si può utilizzare anche con pulsante di emergenza. -Uso Indicato: Quadro Sottocontatore.
7
Quadri ASC Fissi di Distribuzione costruiti in serie secondo CEI 17/13/4 e EN 60439-4: I quadri da cantiere ASC della serie “GENERAL BOX” sono esclusivamente indicati per cantieri di grandi dimensioni. Infatti dove le potenze in gioco sono considerevoli e dove l’area d’estensione del cantiere è grande questi quadri fungono da generali, dai quali vengono smistati i cavi che vanno ad alimentare quadretti di presa a spina. La cassa in poliestere garantisce un’ottimo isolamento tra le parti in tensione e ha una buona resistenza meccanica alle intemperie. Il grado di protezione del quadro a sportello chiuso è IP65. La serie “GENERAL BOX” è ovviamente molto versatile in quanto consente la costruzione di un numero infinito di configurazione di quadro, ed è per questo che ogni quadro verrà progettato e fornito su singola richiesta del cliente. Un Quadro tipo è realizzato con magnetotermico Generale sino a 250A e le linee terminali con interruttori differenziali magnetotermici sino a 63A atte ad alimentare i quadri di distribuzione finale o i quadretti di zona.E’ obbligatorio secondo la norma vigente proteggere tutte le linee terminali sino a 32A con interruttori magnetotermici differenziali con Id=0,03A. -Uso Indicato : Quadro Generale
QQQUUUAAADDDRRRIII EEELLLEEETTTTTTRRRIIICCCIII GGGEEENNNEEERRRAAALLLIII DDDIII DDDIIISSSTTTRRRIIIBBBUUUZZZIIIOOONNNEEE
SSSEEERRRIIIEEE “““GGGEEENNNEEERRRAAALLL BBBOOOXXX”””
Targa di identificazione e Certificazione Ogni quadro è corredato di targa di identificazione e certificazione tecnica con schema elettrico e disegno fronte quadro.
Staffe di fissaggio Il quadro è corredato da staffe di fissaggio che ne permettono un comodo ancoraggio a parete o eventuale cavalletto.
Pressacavi di ingresso e uscita cavi Sul fondo della cassetta è possibile predisporre dei pressacavi per l’ingresso e l’uscita dei cavi dal quadro Il numero e la misura dei pressacavi possono essere scelti in base a esigenze specifiche. Le misure dei pressacavi possono spaziare dal PG 9 al PG 48. .
Morsettiere per allaccio cavi All’interno del quadro è prevista anche la presenza di morsettiere da profilato che servono per allacciare i cavi di alimentazione e di uscita del quadro. Queste morsettiere possono essere di varie misure per poter agganciare conduttori da 4 mmq fino a corde da 95 mmq. Inoltre per allacciare corde ancora più grandi è possibile montare morsetti a bullone dove le corde vengono ancorate tramite capocorda.
8
QQQUUUAAADDDRRRIII EEELLLEEETTTTTTRRRIIICCCIII DDDIII DDDIIISSSTTTRRRIIIBBBUUUZZZIIIOOONNNEEE FFFIIINNNAAALLLEEE
SSSEEERRRIIIEEE “““MMMAAAXXXIIIBBBOOOXXX UUULLLTTTRRRAAA””” “““PPPOOOTTTEEENNNZZZAAA 777777 KKKWWW aaa 444000000VVV”””
CO
DIC
E
PR
ES
E
PRESE INTERBLOCCATE IP67
UNITA’ DI ENTRATA IN
MORSETTIERA 35 mmq.
UNITA’ DI USCITA
63A 3P+N+T 3P+T
32A 3P+N+T 3P+T
16A 3P+N+T 3P+T 2P+T
GE
NE
RA
LE
QU
AD
RO
POTENZA MASSIMA
PROTEZIONE MT 63A 32A 16A
4P 3P 4P 3P 4P 3P2P
QMU2211111
9
1 1 1 1 1 2 2
Mag
neto
term
ico
Gen
eral
e 4P
125
A 1
0 kA
e D
iffer
enzi
ali
I
d=0,
03A
77 Kw/400V 1 1 1 1 2
QMU3200211 1 1 2 2 3 77 Kw/400V 1 1 1 1 3
QMU4210101 1 1 1 2 4 77 Kw/400V 1 1 1 1 2
QMU4111111
10
1 1 1 1 1 1 4 77 Kw/400V 1 1 1 1 1 2
QMU3111211 1 1 2 1 1 1 3 77 Kw/400V 1 1 1 1 1 1 3
QMU6210100 1 1 2 6 77 Kw/400V 1 1 2 6
QMU4221111
12
1 1 1 1 2 2 4 77 Kw/400V 1 1 1 1 1 1 2
QMU3311211 1 1 2 1 1 3 3 77 Kw/400V 1 1 1 1 1 3 3
QMU5211111 1 1 1 1 1 2 5 77 Kw/400V 1 1 1 1 1 1 5
QMU6311100 1 1 1 3 6 77 Kw/400V 1 1 1 3 3
Opzioni: Cavalletto Porta Quadro(Aggiungere al Cod./C Es. QMU2211111/C) ALIMENTAZIONE CON SPINA FISSA 125A APPORRE /SP125 AL COD. ES.(QMU2211111/SP125) per Potenza 77 Kw
Quadri ASC Trasportabili di Distribuzione Finale costruiti in serie secondo CEI 17/13/4 e EN 60439-4: -Grado di Protezione IP67; -Struttura in PVC, la porta si chiude a spine inserite; -Prese Interbloccate Monofase e Trifase da 16 a 63A IP67; -Generale Quadro 4P 125A e differenziali Idn=0,03 e protezione alle prese con M.T. , alimentazione in morsettiera di serie; -Pulsante di Emergenza di serie; -Spina Fissa Opzionabile; - Ciascun quadro è dotato di certificato secondo la norma EN60439/4, e targa di riconoscimento ; -Uso Indicato : Quadro Generale Cantiere.
9
QQQUUUAAADDDRRRIII EEELLLEEETTTTTTRRRIIICCCIII DDDIII DDDIIISSSTTTRRRIIIBBBUUUZZZIIIOOONNNEEE FFFIIINNNAAALLLEEE
SSSEEERRRIIIEEE “““MMMIIINNNIIIBBBOOOXXX CCCLLLAAASSSSSSIIICCC””” “““PPPOOOTTTEEENNNZZZAAA 111888 KKKWWW aaa 444000000VVV”””
CC COO O
DD DII I CC C
EE E
PP PRR R
EE ESS S
EE E
PPPRRREEESSSEEE III NNNTTTEEERRRBBBLLL OOOCCCCCCAAA TTTEEE III PPP666777 UUUNNNIII TTTAAA ’’’ DDDIII EEENNNTTTRRRAAA TTTAAA III NNN SSSPPPIII NNNAAA FFFIII SSSSSSAAA DDDAAA 333222AAA
UUUNNNIII TTTAAA ’’’ DDDIII UUUSSSCCCIII TTTAAA
333222AAA 3P+N+T 3P+T
111666AAA 3P+N+T 3P+T 2P+T
II I N
N NTT T
EE ERR R
RR RUU U
TT TTT T
OO ORR R
EE E
MM MAA A
GG GNN N
EE ETT T
OO OTT T
EE ERR R
MM MII I C
C C OO O
DD DII I F
F F FF F EE E R
R R EE E N
N NZZ Z
II I AA ALL L
EE E
PPPOOOTTTEEENNNZZZAAA MMM AAA SSSSSSIII MMM AAA
PPPRRROOOTTTEEEZZZIII OOONNNEEE CCCOOONNN MMM ...TTT...
111666AAA
444PPP 333PPP 222PPP
QMC21010
4
1 1 2 4x32A/0,03A 18 Kw/400V 1 1 QMC21001 1 1 2 4x32A/0,03A 18 Kw/400V 1 1 QMC21100 1 1 2 4x32A/0,03A 18 Kw/400V 1 1 QMC20011 1 1 2 4x32A/0,03A 18 Kw/400V 1 QMC31000 1 3 4x32A/0,03A 18 Kw/400V 1 1 QMC20101 1 1 2 4x32A/0,03A 18 Kw/400V 1 1 QMC40000 4 2x32A/0,03A 6 Kw/230V 2 QMC22000 2 2 4x32A/0,03A 18 Kw/400V 1 1 QMC22010
5
1 2 2 4x32A/0,03A 18 Kw/400V 1 1 QMC22001 1 2 2 4x32A/0,03A 18 Kw/400V 1 1 QMC21101 1 1 1 2 4x32A/0,03A 18 Kw/400V 1 QMC20201 1 2 2 4x32A/0,03A 18 Kw/400V 1 QMC31010 1 1 3 4x32A/0,03A 18 Kw/400V 1 1 QMC22100 1 2 2 4x32A/0,03A 18 Kw/400V 1 1
DIFFERENZIALE IN CLASSE “A” PER CORRENTI A PULSANTI APPOSITO PER GRU CON INVERTER APPORRE /DA AL COD. ESEMPIO (QMC21010/DA)
Quadri ASC Trasportabili di Distribuzione Finale costruiti in serie secondo CEI 17/13/4 e EN 60439-4: -Grado di Protezione IP67 alimentazione con Spina Fissa 32A -Struttura in Vetroresina, chiusura a spine inserite -Prese Interbloccate Monofase e Trifase da 16 a 32A IP67 -Generale Quadro Idn=0,03A e protezione alle prese con M.T. -Pulsante di Emergenza di serie; -Uso Indicato : Quadro Generale Cantiere.
10
QQQUUUAAADDDRRRIII EEELLLEEETTTTTTRRRIIICCCIII DDDIII DDDIIISSSTTTRRRIIIBBBUUUZZZIIIOOONNNEEE FFFIIINNNAAALLLEEE
SSSEEERRRIIIEEE “““MMMEEEDDDIIIUUUMMMBBBOOOXXX””” PPPOOOTTTEEENNNZZZAAA 333555 KKKWWW aaa 444000000VVV”””
CO
DIC
E
PR
ES
E
PRESE INTERBLOCCATE IP67
UNITA’ DI ENTRATA
SPINA FISSA
3P+N+T 63A
UNITA’ DI USCITA
63A 3P+N+T 3P+T
32A 3P+N+T 3P+T 2P+T
16A 3P+N+T 3P+T 2P+T
GE
NE
RA
LE
QU
AD
RO
PO
TE
NZ
A
MA
SS
IMA
PROTEZIONE MT
63A 32A 16A
4P
3P
4P
3P
1P+
N
4P
3P
1P+
N
QMB32000100
6
1 2 3
Inte
rrut
tore
Mag
neto
term
ico
Diff
eren
zial
e
4P 6
3A I
d=0,
03A
35 K
w/4
00V
1 1 1
QMB22101000 1 1 2 2 1 1 1
QMB21100101 1 1 1 1 2 1 1 1 1
QMB23000100 1 3 2 1 1 1
QMB22111000 1 1 1 2 2 1 1 1 1
QMB31001100 1 1 1 3 1 1 1
QMB32001010
7
1 1 2 3 1 1 1 1
QMB22000201 1 2 2 2 1 1 1 1
QMB31100110 1 1 1 1 3 1 1 1 1
QMB21200101 1 1 2 1 2 1 1 1 1
DIFFERENZIALE IN CLASSE “A” PER CORRENTI A PULSANTI APPOSITO PER GRU CON INVERTER APPORRE /DA AL COD. ESEMPIO (QMB32000100/DA)
Quadri ASC Trasportabili di Distribuzione Finale costruiti in serie secondo CEI 17/13/4 e EN 60439-4: -Grado di Protezione IP67 con chiusura a chiave estraibile; -Struttura in Vetroresina, la porta si chiude a spine inserite; -Prese Interbloccate Monofase e Trifase da 16 a 63A IP67; -Generale Quadro 4P 63A Idn=0,03A e protezione alle prese con M.T. , alimentazione in morsettiera; -Pulsante di Emergenza di serie; -Spina Fissa Opzionabile; -Uso Indicato : Quadro Generale Cantiere.
11
QQQUUUAAADDDRRRIII EEELLLEEETTTTTTRRRIIICCCIII AAASSSCCC DDDIII DDDIIISSSTTTRRRIIIBBBUUUZZZIIIOOONNNEEE FFFIIINNNAAALLLEEE
SSSEEERRRIIIEEE “““BBBEEELLLBBBOOOXXX MMMAAASSSTTTEEERRR”””
MMMooorrrssseeettttttooo dddiii
ttteeerrrrrraaa
PPPrrreeessseee iiinnnttteeerrrbbbllloooccccccaaattteee IIIPPP666777 IIInnnttteeerrrrrruuuttttttooorrriii aaa ppprrrooottteeezzziiiooonnneee ppprrreeessseee SSSpppiiinnnaaa dddiii aaalll iiimmmeeennntttaaazzziiiooonnneee PPPuuulllsssaaannnttteee dddiii eeemmmeeerrrgggeeennnzzzaaa IIInnnttteeerrrrrruuuttttttooorrreee dddiiifff fffeeerrreeennnzzziiiaaallleee ((( IIIddd===000,,,000333AAA)))
CO
DIC
E
PRESE INTERBLOCCATE CEE 17 IP67 UNITA' DI ENTRATA IN
SPINA FISSA UNITA' DI USCITA
PR
ES
E
63A
3P+N+T
32A
3P+N+T 3P+T
16A
3P+N+T 3P+T 2P+T
Inte
rrut
tore
gen
eral
e di
ffere
nzia
le
mag
neto
term
ico
PO
TE
NZ
A
MA
SS
IMA
PROTEZIONE Magnetotermica
32A 16A
4P
4P
3P
2P
QBM320010
6
1 2 3 4x63A/0,03A
35 Kw/400V 1 1 1
QBM221010 1 1 2 2 35 Kw/400V 1 1 1
QBM321000 1 2 3 4x32A/0,03A 18 Kw/400V 1 1 1
QBM411000 1 1 4 4x32A/0,03A 18 Kw/400V 1 2
QBM230010 1 3 2 4x63A/0,03A 35 Kw/400V 1 1 1
QBM420000 2 4 4x32A/0,03A 18 Kw/400V 1 2
QBM330000 3 3 4x32A/0,03A 18 Kw/400V 3 3
QBM220011 1 1 2 2 4x100/0,03A 55 Kw/400V 1 1 1
QBM220010
5
1 2 2 4x63A/0,03A
35 Kw/400V 1 1 1
QBM211010 1 1 1 2 35 Kw/400V 1 1 1
QBM211100 1 1 1 2 4x63A/0,03A 35 Kw/400V 1 1
QBM311000 1 1 3 4x32A/0,03A 18 Kw/400V 1 2
QBM210011 1 1 1 2 4x63A/0,03A 35 Kw/400V 1 1 1
QBM320000 2 3 4x32A/0,03A 18 Kw/400V 1 1
QBM230000 3 2 4x32A/0,03A 18 Kw/400V 1 3
QBM110111 1 1 1 1 1 4x100/0,03A 55 Kw/400V 1 1 1 1
Opzioni: Cavalletto Porta Quadro(Aggiungere al Cod./C Es. QBM320010/C) DIFFERENZIALE IN CLASSE “A” PER CORRENTI A PULSANTI APPOSITO PER GRU CON INVERTER APPORRE /DA AL COD. ESEMPIO (QBM320010/DA)
Quadri ASC Trasportabili di Distribuzione Finale costruiti in serie secondo norma CEI 17/13/4 ed EN 60439-4: -Grado di Protezione IP67 con Spina Fissa di alimentazione o Morsettiera a richiesta; -Contenitori in PVC, chiusura a spine inserite -Prese Interbloccate Monofase e Trifase da 16 a 63A -Generale Quadro Idn=0,03A e protezione alle prese con interruttori Magnetotermici -Pulsante di Emergenza di serie; -Cavalletto Porta quadro opzionabile; -Dichiarazione di Conformità e schema elettrico; Targa di identificazione prodotto; -Uso Indicato : Quadro Generale Cantiere.
12
QQQUUUAAADDDRRRIII EEELLLEEETTTTTTRRRIIICCCIII AAASSSCCC DDDIII PPPRRREEESSSAAA AAA SSSPPPIIINNNAAA “““PPPOOORRRTTTAAABBBLLLEEE BBBOOOXXX”””
“““SSSEEERRRIIIEEE IIIQQQPPP”””
IIInnnttteeerrrrrruuuttttttooorrreee GGGeeennneeerrraaallleee DDDiiiffffffeeerrreeennnzzziiiaaallleee(((IIIddd===000,,,000333AAA)))
SSSpppiiinnnaaa vvvooolllaaannnttteee IIIPPP666777 dddiii aaallliiimmmeeennntttaaazzziiiooonnneee eee cccaaavvvooo
HHH000777RRRNNN--- FFF(((nnneeeoooppprrreeennneee)))
PPPrrreeessseee IIIEEECCC 333000999 111666 AAA
CODICE
Prese CEE 17 IP67 PROTEZIONE Alimentazione
Potenza Erogabile
Pul
sant
e E
mer
genz
a
16A
16A
Differenziale Magnetotermico
0,03A
CAVO H07RN-F
Spina Volante
IQP3M 3 2P 16A 3G2,5 2P+T 16A
3KW/230V NO
IQP3T 3
3P 16A 4G2,5 3P+T 16A
10KW/400V NO
IQP2M1SB 2 1 2P 16A 3G2,5 2P+T 16A
3KW/230V NO
Quadri ASC di presa a spina costruiti in serie secondo le norme CEI 17/13/4 e EN 60439-4: -Grado di Protezione IP67; -Struttura in Termoplastico autoestinguente; -da 2 a 3 Prese IEC 309 16A IP67; -Maniglia per il trasporto; -Interruttore Magnetotermico Diff. Idn=0,03A; -Spina Volante e cavo H07RN-F; -Pulsante di Emergenza di serie su alcuni codici; -Uso Indicato : Quadro di piano, sottoquadro.
13
QQQUUUAAADDDRRRIII EEELLLEEETTTTTTRRRIIICCCIII AAASSSCCC DDDIII PPPRRREEESSSAAA AAA SSSPPPIIINNNAAA “““PPPOOORRRTTTAAABBBLLLEEE BBBOOOXXX”””
“““SSSEEERRRIIIEEE QQQPPP 444 PPPRRREEESSSEEE IIIEEECCC 333000999”””
MMMaaannniiiggglll iiiaaa dddiii tttrrraaassspppooorrrtttooo
PPPiiieeedddiiinnniii ddd’’’aaappppppoooggggggiiiooo sssooottttttoooqqquuuaaadddrrrooo(((ooopppzzziiiooonnnaaalll iii ))) (((///SSS)))
SSSpppiiinnnaaa vvvooolllaaannnttteee IIIPPP666777 dddiii aaalll iiimmmeeennntttaaazzziiiooonnneee eee cccaaavvvooo HHH000777RRRNNN---FFF(((nnneeeoooppprrreeennneee)))
PPPrrreeessseee IIIEEECCC 333000999 111666 ooo 333222AAA
Quadri ASC di presa a spina costruiti in serie secondo le norme CEI 17/13/4 e EN 60439-4: -Struttura in Termoplastico grigio RAL dotati di maniglia; - 4 – 6 - 8 Prese IEC 309 16A IP67; -Interruttore Magnetotermico Differenziale Idn=0,03A; -Interruttori Magnetotermici a protezione delle prese(/P) di serie su alcuni codici; -Spina Volante IP67 e cavo H07RN-F; -Pulsante di Emergenza e terra esterna di serie su alcuni codici; -Piedini d’appoggio sottoquadro opzionabili; -Targa di identificazione Quadro; - Uso Indicato: Quadro di piano, sottoquadro.
14
IIInnnttteeerrrrrruuuttttttooorrriii MMMaaagggnnneeetttooottteeerrrmmmiiiccciii aaa ppprrrooottteeezzziiiooonnneee PPPuuulllsssaaannnttteee dddiii eeemmmeeerrrgggeeennnzzzaaa(((ooopppzzziiiooonnnaaallleee)))
dddeeelll llleee ppprrreeessseee iiinnnssstttaaalll lllaaattteee(((dddiii ssseeerrriiieee sssuuu aaalllcccuuunnniii aaarrrtttiiicccooolll iii )))
TTTaaarrrgggaaa iiidddeeennntttiii fff iiicccaaatttiiivvvaaa ppprrrooodddooottttttooo
MMMooorrrssseeettttttooo dddiii ttteeerrrrrraaa eeesssttteeerrrnnnooo(((dddiii
IIInnnttteeerrrrrruuuttttttooorrreee GGGeeennneeerrraaallleee DDDiiifff fffeeerrreeennnzzziiiaaallleee(((IIIddd===000,,,000333AAA))) ssseeerrriiieee sssuuu qqquuuaaadddrrriii cccooonnn
pppuuulllsssaaannnttteee dddiii eeemmmrrrgggeeennnzzzaaa
CODICE
Prese IEC 309 IP67 PROTEZIONE Alimentazione
Potenza Erogabile
PU
LSA
NT
E
E
ME
RG
EN
ZA
32A
16A
16A
16A
DIF
F.M
T.
Idn
0,03
Automatico
CA
VO
H07
RN
-F
Spina Volante
IP67 3P
16A 1P+N 16A
QP4M 4 2P 16A 3G2,5
3 KW 230V NO
QP4M/P 4 2P 16A 4 3G2,5
3 KW 230V NO
QP4M/E 4 2P 16A 3G2,5
3 KW 230V SI
QP4M/P/E 4 2P 16A 4 3G2,5
3 KW 230V SI
QP3M1T 1 3 4P 16A 5G2,5
10KW/400V 3KW/230V NO
QP3M1T/P/E 1 3 4P 16A 1 1 5G2,5
10KW/400V 3KW/230V NO
QP2M2T 2 2 4P 16A 5G2,5
10KW/400V 3KW/230V NO
QP2M2T/P 2 2 4P 16A 1 1 5G2,5
10KW/400V 3KW/230V NO
QP2M2T/E 2 2 4P 16A 5G2,5
10KW/400V 3KW/230V SI
QP2M2T/P/E 2 2 4P 16A 1 1 5G2,5
10KW/400V 3KW/230V SI
QP4T 4 3P 16A 4G2,5
10KW/400V NO
QP2M1T1TN 1 1 2 4P 16A 5G2,5
10KW/400V 3KW/230V NO
QP2M1T1TN32 1 1 2 4P 32A 1 1 5G6
3P+N+T 32A
18KW/400V 3KW/230V SI
/S PIEDINI D’APPOGGIO SOTTOQUADRO AGGIUNGERE /S AL COD . ES. QP4M/S
15
“““SSSEEERRRIIIEEE QQQPPP 666 PPPRRREEESSSEEE IIIEEECCC 333000999””” SSSpppiiinnnaaa vvvooolllaaannnttteee IIIPPP666777 dddiii aaalll iiimmmeeennntttaaazzziiiooonnneee eee cccaaavvvooo HHH000777RRRNNN---FFF(((nnneeeoooppprrreeennneee)))
MMMaaannniiiggglll iiiaaa dddiii tttrrraaassspppooorrrtttooo PPPuuulllsssaaannnttteee dddiii eeemmmeeerrrgggeeennnzzzaaa(((ooopppzzziiiooonnnaaallleee)))
TTTaaarrrgggaaa iiidddeeennntttiii fff iiicccaaatttiiivvvaaa ppprrrooodddooottttttooo
MMMooorrrssseeettttttooo dddiii ttteeerrrrrraaa eeesssttteeerrrnnnooo(((dddiii
IIInnnttteeerrrrrruuuttttttooorrreee GGGeeennneeerrraaallleee DDDiiifff fffeeerrreeennnzzziiiaaallleee(((IIIddd===000,,,000333AAA))) ssseeerrriiieee sssuuu qqquuuaaadddrrriii cccooonnn pppuuulllsssaaannnttteee dddiii eeemmmrrrgggeeennnzzzaaa
CODICE
Prese IEC 309 IP67 PROTEZIONE Alimentazione
Potenza Erogabile
PU
LSA
NT
E
E
ME
RG
EN
ZA
32A 16A
16A
16A
DIF
F.M
T.
Idn
0,03
Automatico
CA
VO
H07
RN
-F
Spina Volante
IP67 32A
4P 16A
3P 16A
1P+N 16A
QP6M/P 4 1P+N 32A
4 3G6
6 KW 230V NO
QP6M/E 4 1P+N 32A
4 3G6
6 KW 230V SI
QP3M3T/P 3 3 4P
32A
1 2 5G6
18KW/400V 6KW/230V NO
QP3M3T/P/E 3 3 4P
32A
1 2 5G6
18KW/400V 6KW/230V SI
QP4M2T/P 2 4 4P
32A
1 2 5G6
18KW/400V 6KW/230V NO
QP4M2T/P/E 2 4 4P
32A
1 2 5G6
18KW/400V 6KW/230V SI
QP3M2T1TN/P 1 2 3 4P
32A 1 2 5G6
18KW/400V 6KW/230V SI
QP3M2T1TN/P/E 1 2 3 4P
32A 1 2 5G6
18KW/400V 6KW/230V SI
QP2M2T1TN1TN32/P 1 1 2 2
4P 32A
1 2 5G6
18KW/400V 6KW/230V NO
QP2M1T1TN1TN
32/P/E
1 1 2 2 4P
32A 1 2 5G6
18KW/400V 6KW/230V SI
/S PIEDINI D’APPOGGIO SOTTOQUADRO AGGIUNGERE /S AL COD . ES. QP6M/P/S
16
“““SSSEEERRRIIIEEE QQQPPP 888 PPPRRREEESSSEEE IIIEEECCC 333000999””” MMMaaannniiiggglll iiiaaa dddiii tttrrraaassspppooorrrtttooo
PPPuuulllsssaaannnttteee dddiii eeemmmeeerrrgggeeennnzzzaaa(((ooopppzzziiiooonnnaaallleee)))
MMMooorrrssseeettttttooo dddiii ttteeerrrrrraaa eeesssttteeerrrnnnooo(((dddiii ssseeerrriiieee
sssuuu qqquuuaaadddrrriii cccooonnn pppuuulllsssaaannnttteee dddiii eeemmmrrrgggeeennnzzzaaa
TTTaaarrrgggaaa iiidddeeennntttiii fff iiicccaaatttiiivvvaaa ppprrrooodddooottttttooo
IIInnnttteeerrrrrruuuttttttooorrreee GGGeeennneeerrraaallleee DDDiiifff fffeeerrreeennnzzziiiaaallleee(((IIIddd===000,,,000333AAA)))
CODICE
Prese IEC 309 IP67 PROTEZIONE Alimentazione
Potenza Erogabile
PU
LSA
NT
E
E
ME
RG
EN
ZA
32A 16A
16A
16A
DIF
F.M
T.
Idn
0,03
Automatico C
AV
O
H
07R
N-F
Spina
Volante IP67 32A
4P 16A
3P 16A
1P+N 16A
QP8M/P 8 1P+N 32A
8 3G6
6 KW 230V NO
QP8M/E 8 1P+N 32A
8 3G6
6 KW 230V SI
QP4M4T/P 4 4 4P 32A
2 4 5G6
18 KW/400V 12 KW/230V NO
QP4M4T/P/E 4 4 4P
32A
2 4 5G6
18 KW/400V 12 KW/230V SI
QP6M2T/P 2 6 4P
32A
1 6 5G6
18 KW/400V 18 KW/230V NO
QP4M2T/P/E 2 4 4P
32A
2 4 5G6
18 KW/400V 12KW/230V SI
QP4M3T1TN/P 1 3 4 4P
32A 1 1 2 5G6
18 KW/400V 6 KW/230V SI
QP4M3T1TN/P/E 1 3 4 4P
32A 1 1 2 5G6
18 KW/400V 6 KW/230V SI
QP4M2T1TN1TN32/P 1 1 2 4
4P 32A
1 1 2 5G6
18 KW/400V 6 KW/230V NO
QP4M2T1TN1TN
32/P/E
1 1 2 4 4P 32A
1 1 2 5G6
18 KW/400V 6 KW/230V SI
/S PIEDINI D’APPOGGIO SOTTOQUADRO AGGIUNGERE /S AL COD . ES. QP8M/P/S
17
QQQUUUAAADDDRRRIII EEELLLEEETTTTTTRRRIIICCCIII AAASSSCCC TTTRRRAAASSSPPPOOORRRTTTAAABBBIIILLLIII DDDIII DDDIIISSSTTTRRRIIIBBBUUUZZZIIIOOONNNEEE PPPOOORRRTTTAAABBBLLLEEE
BBBOOOXXX “““SSSEEERRRIIIEEE QQQPPPIII”””
SSSEEERRRIIIEEE QQQPPPIII 222 PPPRRREEESSSEEE IIInnnttteeerrrrrruuuttttttooorrreee MMMaaagggnnneeetttooottteeerrrmmmiiicccooo dddiiifff fffeeerrreeennnzzziiiaaallleee ((( IIIddd===000,,,000333AAA))) MMMaaannniiiggglll iiiaaa dddiii tttrrraaassspppooorrrtttooo
PPPuuulllsssaaannnttteee dddiii eeemmmeeerrrgggeeennnzzzaaa(((ooopppzzziiiooonnnaaallleee)))
TTTaaarrrgggaaa iiidddeeennntttiii fff iiicccaaatttiiivvvaaa ppprrrooodddooottttttooo PPPrrreeessseee iiinnnttteeerrrbbbllloooccccccaaattteee IIIPPP666777 111666AAA ooo 333222AAA
MMMooorrrssseeettttttooo dddiii ttteeerrrrrraaa eeesssttteeerrrnnnooo(((dddiii ssseeerrriiieee
sssuuu qqquuuaaadddrrriii cccooonnn pppuuulllsssaaannnttteee dddiii
eeemmmrrrgggeeennnzzzaaa)))
SSSpppiiinnnaaa vvvooolllaaannnttteee IIIPPP666777 dddiii aaalll iiimmmeeennntttaaazzziiiooonnneee eee cccaaavvvooo HHH000777RRRNNN---FFF(((nnneeeoooppprrreeennneee
CODICE
Prese Interbloccate IP67 PROTEZIONE Alimentazione
Potenza Erogabile
PU
LSA
NT
E
E
ME
RG
EN
ZA
32A
16A
16A
16A
DIF
F.M
T.
Idn
0,03
Automatico
CA
VO
H07
RN
-F
Spina Volante 3P
16A 2P
16A
QPI2M 2 2P 16A 3G2,5
3 KW 230V NO
QPI1M1T 1 1 4P 16A 5G2,5
10KW/400V 3KW/230V NO
QPI1M1T/P/E 1 1 4P 16A 1 1 5G2,5
10KW/400V 3KW/230V SI
QPI2T 2 3P 16A 4G2,5
10KW/400V NO
QPI1M1TN 1 1 4P 16A 5G2,5
10KW/400V 3KW/230V NO
QPI2M/P/E 2 2P 16A 2 3G2,5
3 KW 230V SI
QPI2T/E 2 3P 16A 4G2,5
10KW/400V SI
QPI1MT1TN32 1 1 4P 32A 1 5G2,5
18KW/400V 3KW/230V SI
/S PIEDINI D’APPOGGIO SOTTOQUADRO AGGIUNGERE /S AL COD . ES. QPI2M/S
Quadri ASC Trasportabili di Distribuzione costruiti in serie secondo le norme CEI 17/13/4 e EN 60439-4: -Struttura in Termoplastico dotati di maniglia di trasporto e piedini opzionabili; Spina Volante IP67 e cavo H07RN-F; -Interruttori Magnetotermici a protezione delle prese(/P) di serie su alcuni codici; -Pulsante di emergenza e terra esterna di serie su alcuni codici; -da 2 a 4 Prese Interbloccate IP67; -Interruttore Magnetotermico Differenziale Idn=0,03A; Dichiarazione di Conformità e schema elettrico; -Uso Indicato : Quadri Generali per piccoli cantieri di ristrutturazione o Quadri di distribuzione in cantiere.
18
SSSEEERRRIIIEEE QQQPPPIII 333 PPPRRREEESSSEEE
IIInnnttteeerrrrrruuuttttttooorrreee MMMaaagggnnneeetttooottteeerrrmmmiiicccooo dddiiifff fffeeerrreeennnzzziiiaaallleee ((( IIIddd===000,,,000333AAA)))
MMMaaannniiiggglll iiiaaa dddiii tttrrraaassspppooorrrtttooo PPPuuulllsssaaannnttteee dddiii eeemmmeeerrrgggeeennnzzzaaa(((ooopppzzziiiooonnnaaallleee)))
TTTaaarrrgggaaa iiidddeeennntttiii fff iiicccaaatttiiivvvaaa ppprrrooodddooottttttooo
PPPrrreeessseee iiinnnttteeerrrbbbllloooccccccaaattteee IIIPPP666777 111666 ooo 333222AAA SSSpppiiinnnaaa vvvooolllaaannnttteee IIIPPP666777 dddiii aaalll iiimmmeeennntttaaazzziiiooonnneee eee cccaaavvvooo HHH000777RRRNNN---FFF(((nnneeeoooppprrreeennneee))) MMMooorrrssseeettttttooo dddiii ttteeerrrrrraaa eeesssttteeerrrnnnooo(((dddiii ssseeerrriiieee sssuuu
qqquuuaaadddrrriii cccooonnn pppuuulllsssaaannnttteee dddiii eeemmmrrrgggeeennnzzzaaa)))
CODICE
Prese Interbloccate IP67 PROTEZIONE Alimentazione
Potenza Erogabile
PU
LSA
NT
E
E
ME
RG
EN
ZA
32A
16A
16A
16A
DIF
F.M
T.
Idn
0,03
Automatico
CA
VO
H07
RN
-F
Spina Volante 3P
16A 2P
16A
QPI3M 3 2P 16A 3G2,5
3 KW 230V NO
QPI3M/P/E 3 2P 16A 3 3G2,5
3 KW 230V SI
QPI2M1T 1 2 4P 16A 5G2,5
10KW/400V 3KW/230V NO
QPI2M1T/P/E 1 2 4P 16A 1 1 5G2,5
10KW/400V 3KW/230V SI
QPI3T 3 3P 16A 4G2,5
10KW/400V NO
QPI1M1T1TN/P 1 1 1 4P 16A 1 5G2,5
10KW/400V 3KW/230V NO
QPI1T1TN1TN32/E 1 1 1 4P 32A 1 1 5G2,5
10KW/400V 3KW/230V SI
/S PIEDINI D’APPOGGIO SOTTOQUADRO AGGIUNGERE /S AL COD . ES. QPI3M/S
19
SSSEEERRRIIIEEE QQQPPPIII 444 PPPRRREEESSSEEE
IIInnnttteeerrrrrruuuttttttooorrreee MMMaaagggnnneeetttooottteeerrrmmmiiicccooo dddiiifff fffeeerrreeennnzzziiiaaallleee ((( IIIddd===000,,,000333AAA))) PPPuuulllsssaaannnttteee dddiii eeemmmeeegggeeennnzzzaaa(((ooopppzzziiiooonnnaaallleee)))
TTTaaarrrgggaaa iiidddeeennntttiii fff iiicccaaatttiiivvvaaa ppprrrooodddooottttttooo
PPPrrreeessseee iiinnnttteeerrrbbbllloooccccccaaattteee IIIPPP666777 111666 ooo 333222AAA SSSpppiiinnnaaa vvvooolllaaannnttteee IIIPPP666777 dddiii aaalll iiimmmeeennntttaaazzziiiooonnneee eee cccaaavvvooo HHH000777RRRNNN---FFF(((nnneeeoooppprrreeennneee MMMooorrrssseeettttttooo dddiii ttteeerrrrrraaa eeesssttteeerrrnnnooo(((dddiii ssseeerrriiieee sssuuu
qqquuuaaadddrrriii cccooonnn pppuuulllsssaaannnttteee dddiii eeemmmrrrgggeeennnzzzaaa)))
CODICE
Prese Interbloccate IP67 PROTEZIONE Alimentazione
Potenza Erogabile
PU
LSA
NT
E
E
ME
RG
EN
ZA
32A
16A
16A
16A
DIF
F.M
T.
Idn
0,03
Automatico
CA
VO
H07
RN
-F
Spina Volante 3P
16A 2P
16A
QPI4M 4 2P 16A 3G2,5
3 KW 230V NO
QPI4M/P/E 4 2P 16A 4 3G2,5
3 KW 230V SI
QPI2M2T 2 2 4P 16A 5G2,5
10KW/400V 3KW/230V NO
QPI2M2T/P 2 2 4P 16A 1 1 5G2,5
10KW/400V 3KW/230V NO
QPI2M2T/E 2 2 4P 16A 5G2,5
10KW/400V 3KW/230V SI
QPI2M2T/P/E 2 2 4P 16A 1 1 5G2,5
10KW/400V 3KW/230V SI
QPI4T 4 3P 16A 4G2,5
10KW/400V NO
QPI2M1T1TN 1 1 2 4P 16A 5G2,5
10KW/400V 3KW/230V NO
QPI2M1T1TN32/E 1 1 2 4P 32A 1 2 5G6 3P+N+T
32A
18KW/400V 6KW/230V SI
/S PIEDINI D’APPOGGIO SOTTOQUADRO AGGIUNGERE /S AL COD. ES. QPI4M/S
20
QQQUUUAAADDDRRRIII EEELLLEEETTTTTTRRRIIICCCIII AAASSSCCC SSSUUU RRRUUULLLLLLOOO AAAVVVVVVOOOLLLGGGIIICCCAAAVVVOOO ––– RRROOOLLLLLLEEERRR BBBOOOXXX
“““SSSEEERRRIIIEEE AAAQQQ --- AAAQQQIII”””
CODICE
Prese IEC 309 PROTEZIONE Alimentazione
Potenza Erogabile
PU
LSA
NT
E
EM
ER
GE
NZ
A
16A
16A
16A
Diff
eren
zial
e M
agne
tote
rmic
o Id
n=0,
03A
Automatico
CA
VO
H
07R
N-F
Mt.3
0
Spi
na V
olan
te
4P 16A
3P 16A
2P 16A
SSSeeerrriiieee cccooonnn ppprrreeessseee IIIEEECCC 333000999 IIIPPP666777
AQ4M 4 2P 16A 4 3G2,5
3 KW 230V NO
AQ4M/E 4 2P 16A 4 3G2,5
3 KW 230V SI
AQ2M2T 2 2 4P 16A 1 1 5G2,5
10 KW 400V 3 KW 230V
NO
AQ2M2T/E 2 2 4P 16A 1 1 5G2,5
10KW/400V 3KW/230V
SI
AQ2M1T1TN 1 1 2 4P 16A 1 1 5G2,5
10KW/400V 3KW/230V
NO
AQ2M1T1TN/E 1 1 2 4P 16A 1 1 5G2,5
10KW/400V 3KW/230V
SI
SSSeeerrriiieee cccooonnn ppprrreeessseee iiinnnttteeerrrbbbllloooccccccaaattteee IIIEEECCC 333000999 IIIPPP666777
AQI4M 4 2P 16A 4 3G2,5
3 KW 230V NO
AQI4M/E 4 2P 16A 4 3G2,5
3 KW 230V SI
AQI2M2T 2 2 4P 16A 1 1 5G2,5
10 KW 400V 3 KW 230V
NO
AQI2IM2T/E 2 2 4P 16A 1 1 5G2,5
10KW/400V 3KW/230V
SI
AQI2M1T1TIN 1 1 2 4P 16A 1 1 5G2,5
10KW/400V 3KW/230V
NO
AQI2M1T1TIN/E 1 1 2 4P 16A 1 1 5G2,5
10KW/400V 3KW/230V
SI
Quadri ASC Trasportabili di Distribuzione Finale costruiti in serie secondo le norme CEI 17/13/4 e EN 60439-4: -Struttura in Termoplastico grigio RAL 7035; -n. 4 Prese IEC 309 o Prese Interbloccate IP67; -Interruttore Magnetotermico Differenziale Idn=0,03A; -Spina Volante e cavo H07RN-F; -Pulsante di Emergenza di serie su alcuni codici; -Avvolgicavo Industriale carrellato con 30 mt di cavo H07RN-F e presa per collegamento alla spina in uscita dal quadro elettrico; -Uso Indicato : Quadri Generali per piccoli cantieri di ristrutturazione.
21
AAAVVVVVVOOOLLLGGGIIICCCAAAVVVOOO IIINNNDDDUUUSSSTTTRRRIIIAAALLLEEE MMMEEEDDDIIIUUUMMM RRROOOLLLLLLEEERRR “““SSSEEERRRIIIEEE AAAVVV”””
FFFeeerrrmmmaaacccaaavvvooo iiinnn aaacccccciiiaaaiiiooo DDDiiisssgggiiiuuunnntttooorrreee TTTeeerrrmmmiiicccooo
CODICE
Prese IEC 309 IP67 Alimentazione
Potenza Erogabile(Watt)
16A
16A
Schuko(S)
Bivalente(B)
CAVO H07RN-F
Mt.
Spina Volante 16A IP67
SEZ. CAVO
AV2M6720 2 20 mt. 2P+T 16A
3G2,5 1800 3600
AV2T6720 2 20 mt.
3P+T 16A
4G2,5 5500 11000
AV1M1T6720 1 1 20 mt.
3P+N+T 16A
5G2,5 5500 11000
AV2M6730 2 30 mt. 2P+T 16A
3G2,5 1800 3600
AV2T6730 2 30 mt.
3P+T 16A
4G2,5 5500 11000
AV1M1T6725 1 1 25 mt.
3P+N+T 16A
5G2,5 5500 11000
AV2M6740 2 40 mt. 2P+T 16A
3G2,5 1800 3600
AV2M6720/3G1,5 2 20 mt. 2P+T 16A
3G1,5 1100 2200
AV2M6725/3G1,5 2 25 mt.
2P+T 16A
3G1,5 1100 2200
AV2M6730/3G1,5 2 30 mt.
2P+T 16A
3G1,5 1100 2200
AV1M1S1B4430 1 1(S) - 1(B) 30 mt. 2P+T 16A
3G2,5 1800 3600
AV1M1B4430 1 1(B) 30 mt. 2P+T 16A
3G2,5 1800 3600
AV1M1S4430 1 1(S) 30 mt.
2P+T 16A
3G2,5 1800 3600
Avvolgicavo Industriale costruito secondo le norme CEI 13-16 : -Tubolare di supporto in metallo resistente agli urti e agli agenti atmosferici, Grado di protezione IP67; -n.2 Prese IEC 309 IP67; -Disgiuntore Termico sulla versione monofase; -Protezione magnetotermica con fusibili sulla versione trifase; -Spina Volante IP67 e cavo H07RN-F; -Uso Indicato : Per Collegamento mobile in cantiere.
22
AAAVVVVVVOOOLLLGGGIIICCCAAAVVVOOO IIINNNDDDUUUSSSTTTRRRIIIAAALLLEEE CCCOOONNN TTTAAAMMMBBBUUURRROOO IIINNN PPPLLLAAASSSTTTIIICCCAAA EEE
RRRUUULLLLLLOOO CCCOOONNN RRRUUUOOOTTTEEE MMMAAAXXXIII RRROOOLLLLLLEEERRR “““SSSEEERRRIIIEEE AAAVVVGGG”””
ARTICOLO
Prese IEC 309 IP67
Alimentazione
SEZ. CAVO Potenza
Erogabile(Watt) 16A
16A
CAVO H07RN-F
Mt.
Spina Volante IP67
AVG2M6750 2 50 mt. 2P+T 16A
3G2,5 1800 3600
AVG2T6750 2 50 mt.
3P+T 16A
4G2,5 5500 11000
AVG2M6770 2 70 mt. 2P+T 16A
3G2,5 1800 3600
AVG2T6770 2 70 mt.
3P+T 16A
4G2,5 5500 11000
AVG1M1T6750 1 1 50 mt.
3P+N+T 16A
5G2,5 5500 11000
AVG1M1T6770 1 1 70 mt.
3P+N+T 16A
5G2,5 5500 11000
Avvolgicavo Industriale costruito secondo le norme CEI 13-16: -Tamburo in Termoplastico autoestinguente ; -Tubolare in metallo di colore nero con ruote per il trasporto - 2 Prese IEC 309 IP67; -Disgiuntore Termico sulla versione monofase; -Protezione magnetotermica con fusibili sulla versione trifase; -Spina Volante IEC 309 IP67 e cavo H07RN-F; -Uso indicato : Per Collegamento mobile in Cantiere.
23
AAAVVVVVVOOOLLLGGGIIICCCAAAVVVOOO BBBRRRIIICCCOOOLLLAAAGGGEEE MMMIIINNNIII RRROOOLLLLLLEEERRR ––– “““SSSEEERRRIIIEEE AAAVVVBBB””” Cavo H05VV-F Spine e prese Civili e Schuko 16A (1) (2)
AVB4BS1544(fig.1) 3(S) - 4(B) 15 mt. 2P+T 16A(civile) 3G1,5 1100 2200
AVB2B2S2544(fig.2) 3(S) - 4(B) 25 mt. 2P+T 16A(civile) 3G1,5 1100 2200
AVB2B2S5044(fig.2) 3(S) - 4(B) 50 mt. 2P+T 16A(civile) 3G1,5 1100 2200
TTTRRRAAASSSFFFOOORRRMMMAAATTTOOORRRIII 222333000///222444VVV TTTRRRAAASSSFFFOOORRRMMMEEERRR BBBOOOXXX ––– SSSEEERRRIIIEEE “““AAALLL ––– QQQTTT”””
SSSEEERRRIIIEEE AAALLL SSSEEERRRIIIEEE QQQTTT
PPPrrreeessseee IIIEEECCC333000999 222444 VVV FFFuuusssiiibbbiii lll iii dddiii ppprrrooottteeezzziiiooonnneee ppprrriiimmmaaarrriiiooo eee ssseeecccooonnndddaaarrriiiooo
ARTICOLO
PRESE IEC 309 IP44
Interruttore M.T.D. 0,03A
Fusibili di Protezione
Trasformatore di Sicurezza
Crepuscolare o Orologio
2P 16A 24V
2P+T 16A 230V
AL2/24V/100 2
---------------
n.2 100 VA NO
AL2/24V/150 2 n.2 150 VA NO
AL/2/24V/100/CR 2 n.2 100 VA SI
AL/2/24V/150/CR 2 n.2 150 VA SI
QT2M/1-24V 1 2 2P - 16A/0,03A n.1 150 VA NO
QT2M/1-24V/CR 1 2 2P - 16A/0,03A n.1 150 VA SI
QT3-24V 3 2P - 16A/0,03A n.1 150 VA NO
QT2-24V/CR 2 2P - 16A/0,03A n.1 150 VA SI
Quadri ASC di trasformazione costruiti in serie secondo le norme EN 60742 e CEI 14-16: -Struttura in Termoplastico dotati di maniglia; -da 2 a 3 Prese IEC 309 IP44 16A – 24 V o 2P+T; -Interruttore Differenziale 0,03A o Fusibili sul primario e sul secondario; -Spina Volante e cavo H07RN-F; -Trasformatore di sicurezza 230V/24V 100 o 150VA; -Uso Indicato : Alimentazione luci ponteggi con lampade 24V.
Avvolgicavo Civile costruito secondo le norme CEI 13-16 : -Tamburo in plastica e tubolare in metallo resistente agli urti e agli agenti atmosferici, Grado di protezione IP44; - 2 Prese Schuko e 2 bivalenti e /o 4 Trivalenti; -Disgiuntore Termico; -Spina Volante 2P+T 16A Civile; -Uso Indicato : Per Collegamento mobile in giardino.
24
LLLUUUCCCIII PPPEEERRR PPPOOONNNTTTEEEGGGGGGIIIOOO CCCOOONNN AAAGGGGGGAAANNNCCCIII ––– “““SSSEEERRRIIIEEE LLLPPP”””
PPPrrreeesssaaa dddiii cccooonnntttiiinnnuuuiiitttààà(((ooopppzzziiiooonnnaaallleee))) (((///PPPRRR)))
MMMiiicccrrroooppplllaaafffooonnniiieeerrreee RRRooosssssseee cccooonnn lllaaammmpppaaadddaaa 222444VVV 555WWW
ARTICOLO N.LAMPADE
WATT
DISTANZA TRA SPINA E 1° LAMPADA
DISTANZA TRA LAMPADE
SPINA DI ALIMENTAZIONE
LP2 n.2- 10 Watt 5 mt. 4mt. 2P – 24V – 16A LP3 n.3- 10 Watt 5 mt. 4mt. 2P – 24V – 16A LP4 n.4- 10 Watt 5 mt. 4mt. 2P – 24V – 16A LP5 n.5- 10 Watt 5 mt. 4mt. 2P – 24V – 16A LP6 n.6- 10 Watt 5 mt. 4mt. 2P – 24V – 16A LP7 n.7- 10 Watt 5 mt. 4mt. 2P – 24V – 16A LP8 n.8- 10 Watt 5 mt. 4mt. 2P – 24V – 16A LP9 n.9- 10 Watt 5 mt. 4mt. 2P – 24V – 16A LP10 n.10- 10 Watt 5 mt. 4mt. 2P – 24V – 16A
/PR AGGIUNGERE /PR AL CODICE PER OPZIONARE LA PRESA DI CONTINUITA’ ES.LP5/PR
LLLEEEDDD SSSTTTRRRAAADDDAAALLLIII CCCOOONNN GGGAAANNNCCCIIIOOO SSSUUUPPPEEERRRIIIOOORRREEE --- SSSEEERRRIIIEEE LLLEEEDDD SSSTTTRRREEEEEETTT
CODICE DESCRIZIONE
LSG Lampada di segnalazione a Batteria funzione luce fissa o intermittente con Crepuscolare colore Giallo
LSR Lampada di segnalazione a Batteria funzione luce fissa o intermittente con Crepuscolare colore Rosso
BLS Batteria 6 Volt extra durata, senza mercurio.
Gruppi di microplafoniere rosse a 24V costruiti secondo le norme CEI 34/21 e 34/23 : -Lampadine da 5 W 24V; -Cavo Fror 450/750 2x1 ; -Spina di alimentazione 2P 24V 16A IP44; -Supporto in plastica per aggancio a ponteggio; -Uso Indicato : Segnalazione Ponteggi accoppiabili con alimentatore AL o QT.
25
AAADDDAAATTTTTTAAATTTOOORRRIII IIINNNDDDUUUSSSTTTRRRIIIAAALLLIII ––– “““SSSEEERRRIIIEEE AAADDD”””
CODICE DESCRIZIONE
ADCS(1) ADATTATORE DA SPINA CEE MONOFASE 16A A PRESA SCHUKO
ADCB(2) ADATTATORE DA SPINA MONOFASE 16A A PRESA BI VALENTE 10-16A ADCBS(3) ADATTATORE DA SPINA CEE MONOFASE A PRESA SCHUKO E BIVALENTE 16A
ADCBB(4) ADATTATORE DA SPINA CEE MONOFASE A DOPPIA PRESA BIVALENTE 16A ADPC(5) ADATTATORE DA SPINA A PETTINE 10/16A A PRESA MONOFASE 16A ADSC(6) ADATTATORE DA SPINA SCHUKO A PRESA CEE MONO FASE 16A
ADCBST(7) ADATTATORE DA SPINA CEE MONOFASE A TRIPLA PRESA SCH UKO E BIVALENTE 16A
PPPRRROOOIIIEEETTTTTTOOORRRIII AAALLLOOOGGGEEENNNIII ––– “““SSSEEERRRIIIEEE PPPAAALLL””” Fig. 1 Fig. 2
ARTICOLO DESCRIZIONE VOLT
PAL/PI (fig.1) Proiettore Alogeno su supporto con lampada 500 Watt con 3 mt. cavo H05RN-F e spina CEE 2P+T 16A IP67
230
PAL/TP (fig.2) Proiettore Alogeno su Treppiede telescopico con lampada 500 Watt con 5 mt. di cavo H07RN-F e spina CEE 2P+T IP67
230
Faretti alogeni : -Grado di Protezione IP54; -Realizzati in alluminio presso fuso verniciato a forno con polveri poliuretaniche; -Riflettore in alluminio di elevata purezza; -Lampade alogene da 400W; -Spina Volante e cavo H07RN-F; - Lampade incluse; -Uso Indicato: Cantieri sotterranei – cave o miniere.
Adattatori Industriali: -Grado di Protezione IP44; -Uso Indicato : Solo per uso temporaneo non possono alimentare macchine fisse.
26
SSSAAALLLVVVAAAMMMOOOTTTOOORRRIII PPPEEERRR MMMAAACCCCCCHHHIIINNNEEE EEEDDDIIILLLIII --- “““SSSEEERRRIIIEEE SSSMMM”””
SSSpppiiinnnaaa dddiii aaalll iiimmmeeennntttaaazzziiiooonnneee IIIPPP666777
CCCaaavvvooo dddiii aaalll iiimmmeeennntttaaazzziiiooonnneee mmmoootttooorrreee LLL=== 888000 cccmmm...
PPPuuulllsssaaannnttteee dddiii eeemmmeeerrrgggeeennnzzzaaa cccooonnn bbbllloooccccccooo mmmeeeccccccaaannniiicccooo
VVVeeerrrsssiiiooonnneee cccooonnn ssspppiiinnnaaa vvvooolllaaannnttteee IIIPPP666777
ARTICOLO TIPO DI
INGRESSO Spina Fissa
VOLTS AMPERE POTENZA
KW(chilowatt) HP(cavalli motore)
SMRMF 6,3-10 A
230 V 6,3-10 A 1,4 - 2,5 2 - 3,5
SMRMF 10-16 A
230 V 10-16 A 2,5 - 4,4 3,5 - 6,0
SMRTF 6,3 - 10 A
400 V 6,3 - 10 A 2,9 - 4,4 4,0 - 6,0
SMRTF 10 - 16 A
400 V 10 - 16 A 4,4 - 8,0 6,0 – 11,0
ARTICOLO TIPO DI
INGRESSO Spina Volante
VOLTS AMPERE POTENZA
KW(chilowatt) HP(cavalli motore)
SMRMFV 6,3-10 A
230 V 6,3-10 A 1,4 - 2,5 2 - 3,5
SMRMFV 10-16 A
230 V 10-16 A 2,5 - 4,4 3,5 - 6,0
SMRTFV 6,3 - 10 A
400 V 6,3 - 10 A 2,9 - 4,4 4,0 - 6,0
SMRTFV 10 - 16 A
400 V 10 - 16 A 4,4 - 8,0 6,0 – 11,0
SMRTFNV 10 - 16 A
400 V 3P+N+T
10 - 16 A 4,4 - 8,0 6,0 – 11,0
Salvamotori Magnetotermici costruiti secondo le norme EN 60947-4-1/A1: -Grado di Protezione IP55; -Cassetta in Termoplastico grigio RAL; -Pulsante di emergenza con blocco a rotazione; -Salvamotore Magnetotermico Lovato con bobina di minima tensione; -Spina Volante o fissa al corpo della cassetta; -Cavo di alimentazione (L=80 cm.) motore con faston ad occhiello; -Uso Indicato : Protezione e avviamento sui motori di macchine come: Betoniere, Molazze, Segatrici , Idropulitrici o Spaccalegna.
27
CCCAAAVVVOOO HHH000777RRRNNN---FFF IIINNN MMMAAATTTAAASSSSSSIIINNNEEE DDDAAA 111000000 MMMTTT... ––– “““SSSEEERRRIIIEEE CCCVVVNNN”””
PPPRRROOOLLLUUUNNNGGGHHHEEE IIINNNDDDUUUSSSTTTRRRIIIAAALLLIII CCCOOONNN CCCAAAVVVOOO HHH000777RRRNNN---FFF ––– “““SSSEEERRRIIIEEE PPPLLLNNN”””
PROLUNGHE INDUSTRIALI CON PRESE E SPINE IP67
CODICE LUNGHEZZA
MT. SEZIONE DEL
CAVO H07RN-F SPINA E PRESA CEE 17 IP67
PLNM10/3G1,5 10 3G1,5 2P+T - 16A - 230V PLNM10/3G2,5 10 3G2,5 2P+T - 16A - 230V
PLNT10/4G2,5 10 4G2,5 3P+T - 16A - 400V PLNT10/5G2,5 10 5G2,5 3P+N+T - 16A - 400V PLNM20/3G1,5 20 3G1,5 2P+T - 16A - 230V PLNM20/3G2,5 20 3G2,5 2P+T - 16A - 230V PLNT20/4G2,5 20 4G2,5 3P+T - 16A - 400V PLNT20/5G2,5 20 5G2,5 3P+N+T - 16A - 400V
PLNM30/3G1,5 30 3G1,5 2P+T - 16A - 230V
PLNM30/3G2,5 30 3G2,5 2P+T - 16A - 230V PLNT30/4G2,5 30 4G2,5 3P+T - 16A - 400V PLNT30/5G2,5 30 5G2,5 3P+N+T - 16A - 400V PLNM50/3G1,5 50 3G1,5 2P+T - 16A - 230V
PLNM50/3G2,5 50 3G2,5 2P+T - 16A - 230V
PLNT50/4G2,5 50 4G2,5 3P+T - 16A - 400V PLNT50/5G2,5 50 5G2,5 3P+N+T - 16A - 400V
NNNNNNNNNNNN............BBBBBBBBBBBB............ :::::::::::: iiiiiiiiiiii llllllllllll llllllllllll iiiiiiiiiiiissssssssssssttttttttttttiiiiiiiiiiiinnnnnnnnnnnnoooooooooooo ccccccccccccaaaaaaaaaaaavvvvvvvvvvvviiiiiiiiiiii eeeeeeeeeeee pppppppppppprrrrrrrrrrrroooooooooooolllllllllllluuuuuuuuuuuunnnnnnnnnnnngggggggggggghhhhhhhhhhhheeeeeeeeeeee èèèèèèèèèèèè ssssssssssssooooooooooooggggggggggggggggggggggggeeeeeeeeeeeettttttttttttttttttttttttoooooooooooo aaaaaaaaaaaadddddddddddd aaaaaaaaaaaauuuuuuuuuuuummmmmmmmmmmmeeeeeeeeeeeennnnnnnnnnnnttttttttttttiiiiiiiiiiii ppppppppppppeeeeeeeeeeeerrrrrrrrrrrrttttttttttttaaaaaaaaaaaannnnnnnnnnnnttttttttttttoooooooooooo èèèèèèèèèèèè nnnnnnnnnnnneeeeeeeeeeeecccccccccccceeeeeeeeeeeessssssssssssssssssssssssaaaaaaaaaaaarrrrrrrrrrrriiiiiiiiiiiioooooooooooo rrrrrrrrrrrriiiiiiiiiiiicccccccccccchhhhhhhhhhhhiiiiiiiiiiiieeeeeeeeeeeeddddddddddddeeeeeeeeeeeerrrrrrrrrrrreeeeeeeeeeee sssssssssssseeeeeeeeeeeemmmmmmmmmmmmpppppppppppprrrrrrrrrrrreeeeeeeeeeee
ccccccccccccoooooooooooonnnnnnnnnnnnffffffffffffeeeeeeeeeeeerrrrrrrrrrrrmmmmmmmmmmmmaaaaaaaaaaaa ddddddddddddeeeeeeeeeeeellllllllllll pppppppppppprrrrrrrrrrrreeeeeeeeeeeezzzzzzzzzzzzzzzzzzzzzzzzoooooooooooo ffffffffffffiiiiiiiiiiiinnnnnnnnnnnnaaaaaaaaaaaalllllllllllleeeeeeeeeeee iiiiiiiiiiiinnnnnnnnnnnn ddddddddddddiiiiiiiiiiiittttttttttttttttttttttttaaaaaaaaaaaa............
CODICE SEZIONE DEL
CAVO H07RN-F LUNGHEZZA
MT.
CCCVVV NNN222GGG111 222xxx111 mmmmmmqqq... 111000000
CCCVVV NNN333GGG111,,,555 333xxx111,,,555 mmmmmmqqq... 111000000
CCCVVV NNN333GGG222,,,555 333xxx222,,,555 mmmmmmqqq... 111000000
CCCVVV NNN444GGG222,,,555 444xxx222,,,555 mmmmmmqqq... 111000000
CCCVVV NNN555GGG222,,,555 555xxx222,,,555 mmmmmmqqq... 111000000
CCCVVV NNN555GGG444 555xxx444 mmmmmmqqq... 111000000
CCCVVV NNN555GGG666
555xxx666 mmmmmmqqq... 111000000
Prolunghe con cavo H07RN-F per posa mobile: -Spine e prese IP67(stagne); -Diverse metrature di cavo H07RN-F Pirelli; -Uso Indicato : Collegamento mobile in cantiere.
Cavo elettrico H07RN-F rispetto alle norme CEE 64-8V7(per posa mobile): -Flessibilissimo anche a basse temperature; -Matassine da 100 mt. di cavo; -Uso Indicato : Collegamento mobile in cantiere.
28
PPPAAARRRTTTIIITTTOOORRRIII DDDIII TTTEEENNNSSSIIIOOONNNEEE PPPEEERRR UUUSSSOOO TTTEEEMMMPPPOOORRRAAANNNEEEOOO ––– “““SSSEEERRRIIIEEE PPPAAA”””
COD. IP44 PRESE 16A SPINA DI
ALIMENTAZIONE
PA2M44
2P+T 16A
PA2T44
3P+T 16A
PA3M44
2P+T 16A
PA3T44
3P+T 16A
COD. IP67 PRESE 16A SPINA DI
ALIMENTAZIONE
PA2M67
2P+T 16A
PA2T67
3P+T 16A
PA3M67
2P+T 16A
PA3T67
3P+T 16A
PA2M1T67
3P+N+T 16A
Partitori di tensione: -Prese e spine IP44 o IP 67; -Grado di Protezione IP44 o IP67 -Uso Indicato : Solo per uso temporaneo non possono alimentare macchine fisse.
29
SSSPPPIIINNNEEE EEE PPPRRREEESSSEEE VVVOOOLLLAAANNNTTTIII IIINNNDDDUUUSSSTTTRRRIIIAAALLLIII ––– “““SSSEEERRRIIIEEE SSSPPP ––– PPPRRR”””
SPINE VOLANTI INDUSTRIALI IP44 – IP67 CODICE IP44 CODICE IP67 N. POLI - AMPERE - VOLTS
SP24V44 SP24V67 2P - 16A - 24V SPMF4416 SPMF6716 2P+T - 16A - 230V SPTF4416 SPTF6716 3P+T - 16A - 400V
SPTF+N4416 SPTF+N6716 3P+N+T - 16A – 400V SPMF4432 SPMF6732 2P+T - 32A - 230V SPTF4432 SPTF6732 3P+T - 32A - 400V
SPTF+N4432 SPTF+N6732 3P+N+T - 32A – 400V SPTF6763 3P+T - 63A - 400V
SPTF+N6763 3P+N+T - 63A – 400V PRESE VOLANTI INDUSTRIALI IP44 - IP67
CODICE IP44 CODICE IP67 N. POLI - AMPERE - VOLTS PR24V44 PR24V67 2P - 16A - 24V
PRMF4416 PRMF6716 2P+T - 16A - 230V PRTF4416 PRTF6716 3P+T - 16A - 400V
PRTF+N4416 PRTF+N6716 3P+N+T - 16A – 400V
PRMF4432 PRMF6732 2P+T - 32A - 230V PRTF4432 PRTF6732 3P+T - 32A - 400V
PRTF+N4432 PRTF+N6732 3P+N+T - 32A – 400V PRTF6763 3P+T - 63A - 400V PRTF+N6763 3P+N+T - 63A – 400V
Spine e prese Volanti Industriali: -Prese e spine IP44 o IP 67; -Materiale in termoplastico antiurto e autoestinguente. -Uso Indicato : Collegamento mobile in cantiere.
30
SSSPPPIIINNNEEE EEE PPPRRREEESSSEEE 222PPP+++TTT DDDAAA 111000AAA &&&111666AAA 222555000VVV--- SSSEEERRRIIIEEE “““SSSPPPCCC ––– PPPRRRCCC””” Fig. 1 Fig. 2 Fig.3 Fig. 4
CCCOOODDDIIICCCEEE DDDEEESSSCCCRRRIIIZZZIIIOOONNNEEE
SSSPPPCCC111000BBB(((111))) SSSpppiiinnnaaa VVVooolllaaannnttteee DDDiiirrr iii ttt tttaaa 222PPP+++TTT 111000AAA 222555000VVV IIIPPP222000
SSSPPPCCC111666BBB(((111))) SSSpppiiinnnaaa VVVooolllaaannnttteee DDDiiirrr iii ttt tttaaa 222PPP+++TTT 111666AAA 222555000VVV IIIPPP222000
PPPRRRCCC111666BBB(((222))) PPPrrreeesssaaa VVVooolllaaannnttteee DDDiiirrr iii ttt tttaaa 222PPP+++TTT 111666AAA 222555000VVV IIIPPP222000
SSSPPPCCC111666SSS(((333))) SSSpppiiinnnaaa VVVooolllaaannnttteee SSSccchhhuuukkkooo 222PPP+++TTT 111666AAA 222555000VVV IIIPPP222000
PPPRRRCCC111666SSS(((444))) PPPrrreeesssaaa VVVooolllaaannnttteee SSSccchhhuuukkkooo 222PPP+++TTT 111666AAA 222555000VVV IIIPPP222000
AAADDDAAATTTTTTAAATTTOOORRRIII 222PPP+++TTT DDDAAA 111000AAA EEE 111666AAA 222555000VVV--- SSSEEERRRIIIEEE AAADDDCCC Fig. 1 Fig. 2 Fig. 3 Fig. 4
CCCOOODDDIIICCCEEE DDDEEESSSCCCRRRIIIZZZIIIOOONNNEEE
AAADDDCCC111000333BBB(((111))) AAAdddaaattt tttaaatttooorrreee SSSpppiiinnnaaa 222PPP+++TTT 111000AAA 222555000VVV IIIPPP222000 eee nnn...333 ppprrreeessseee bbbiiipppaaassssssooo 111000///111666AAA
AAADDDCCC111666333BBB(((111))) AAAdddaaattt tttaaatttooorrreee SSSpppiiinnnaaa 222PPP+++TTT 111666AAA 222555000VVV IIIPPP222000 eee nnn...333 ppprrreeessseee bbbiiipppaaassssssooo 111000///111666AAA
AAADDDCCC111666222BBB111SSS(((222))) AAAdddaaattt tttaaatttooorrreee SSSpppiiinnnaaa 222PPP+++TTT 111666AAA 222555000VVV IIIPPP222000 eee nnn...222 ppprrreeessseee bbbiiipppaaassssssooo 111000///111666AAA+++nnn...111 SSSccchhhuuukkkooo 111666AAA
AAADDDCCC111000SSS(((333))) AAAdddaaattt tttaaatttooorrreee dddaaa SSSpppiiinnnaaa 222PPP+++TTT 111000AAA 222555000VVV IIIPPP222000 aaa SSSccchhhuuukkkooo 111000///111666AAA
AAADDDCCC111666SSS(((333))) AAAdddaaattt tttaaatttooorrreee dddaaa SSSpppiiinnnaaa 222PPP+++TTT 111666AAA 222555000VVV IIIPPP222000 aaa SSSccchhhuuukkkooo 111000///111666AAA
AAADDDCCC111666BBB(((444))) AAAdddaaattt tttaaatttooorrreee dddaaa SSSpppiiinnnaaa 222PPP+++TTT 111666AAA 222555000VVV IIIPPP222000 aaa BBBiiipppaaassssssooo 111000///111666AAA
Adattatori Civili: -Prese e spine civili; -Materiale in termoplastico antiurto e autoestinguente. -Alveoli e spinotti attivi protetti da contatti accidentali; Potenza massima prelevabile 1500W;
Spine e prese Volanti Civili: -Materiale in termoplastico antiurto e autoestinguente; -Alveoli e spinotti attivi protetti da contatti accidentali; -Confezione Pz.25.
31
PPPRRREEESSSEEE MMMUUULLLTTTIIIPPPLLLEEE --- SSSEEERRRIIIEEE PPPMMM
Fig. 1 Fig. 2 Fig. 3 Fig. 4
Fig. 5 Fig. 6 Fig. 7 Fig. 8
Fig. 9 Fig. 10 Fig. 11 Fig. 12
CCCOOODDDIIICCCEEE DDDEEESSSCCCRRRIIIZZZIIIOOONNNEEE
PPPMMM333(((111))) PPPrrreeesssaaa mmmuuulll ttt iiippplllaaa 333 uuusssccciii ttteee SSSpppiiinnnaaa 222PPP+++TTT 111666AAA 222555000VVV eee nnn...333 ppprrreeessseee bbbiiipppaaassssssooo 111000///111666AAA
PPPMMM444(((222))) PPPrrreeesssaaa mmmuuulll ttt iiippplllaaa 444 uuusssccciii ttteee SSSpppiiinnnaaa 222PPP+++TTT 111666AAA 222555000VVV eee nnn...444 ppprrreeessseee bbbiiipppaaassssssooo 111000///111666AAA
PPPMMM555(((333))) PPPrrreeesssaaa mmmuuulll ttt iiippplllaaa 555 uuusssccciii ttteee SSSpppiiinnnaaa 222PPP+++TTT 111666AAA 222555000VVV eee nnn...555 ppprrreeessseee bbbiiipppaaassssssooo 111000///111666AAA
PPPMMM666(((444))) PPPrrreeesssaaa mmmuuulll ttt iiippplllaaa 666 uuusssccciii ttteee SSSpppiiinnnaaa 222PPP+++TTT 111666AAA 222555000VVV eee nnn...666 ppprrreeessseee bbbiiipppaaassssssooo 111000///111666AAA
PPPMMM333III(((555))) PPPrrreeesssaaa mmmuuulll ttt iiippplllaaa 333 uuusssccciii ttteee SSSpppiiinnnaaa 222PPP+++TTT 111666AAA 222555000VVV eee nnn...333 ppprrreeessseee bbbiiipppaaassssssooo+++sssccchhhuuukkkooo 111000///111666AAA cccooonnn iiinnnttteeerrrrrruuuttt tttooorrreee llluuummmiiinnnooosssooo
PPPMMM444III(((666))) PPPrrreeesssaaa mmmuuulll ttt iiippplllaaa 444 uuusssccciii ttteee SSSpppiiinnnaaa 222PPP+++TTT 111666AAA 222555000VVV eee nnn...444 ppprrreeessseee bbbiiipppaaassssssooo+++sssccchhhuuukkkooo 111000///111666AAA cccooonnn iiinnnttteeerrrrrruuuttt tttooorrreee llluuummmiiinnnooosssooo
PPPMMM555III(((777))) PPPrrreeesssaaa mmmuuulll ttt iiippplllaaa 555 uuusssccciii ttteee SSSpppiiinnnaaa 222PPP+++TTT 111666AAA 222555000VVV eee nnn...555 ppprrreeessseee bbbiiipppaaassssssooo+++sssccchhhuuukkkooo 111000///111666AAA cccooonnn iiinnnttteeerrrrrruuuttt tttooorrreee llluuummmiiinnnooosssooo
PPPMMM666III(((888))) PPPrrreeesssaaa mmmuuulll ttt iiippplllaaa 666 uuusssccciii ttteee SSSpppiiinnnaaa 222PPP+++TTT 111666AAA 222555000VVV eee nnn...666 ppprrreeessseee bbbiiipppaaassssssooo+++sssccchhhuuukkkooo 111000///111666AAA cccooonnn iiinnnttteeerrrrrruuuttt tttooorrreee llluuummmiiinnnooosssooo
PPPMMM444IIIQQQ(((999))) PPPrrreeesssaaa mmmuuulll ttt iiippplllaaa 444 uuusssccciii ttteee SSSpppiiinnnaaa 222PPP+++TTT 111666AAA 222555000VVV eee nnn...444 ppprrreeessseee bbbiiipppaaassssssooo+++sssccchhhuuukkkooo 111000///111666AAA cccooonnn iiinnnttteeerrrrrruuuttt tttooorrreee llluuummmiiinnnooosssooo
PPPMMM666IIIQQQ(((111000))) PPPrrreeesssaaa mmmuuulll ttt iiippplllaaa 666 uuusssccciii ttteee SSSpppiiinnnaaa 222PPP+++TTT 111666AAA 222555000VVV eee nnn...666 ppprrreeessseee bbbiiipppaaassssssooo+++sssccchhhuuukkkooo 111000///111666AAA cccooonnn iiinnnttteeerrrrrruuuttt tttooorrreee llluuummmiiinnnooosssooo
PPPMMM333BBB333SSS(((111111))) PPPrrreeesssaaa mmmuuulll ttt iiippplllaaa 666 uuusssccciii ttteee SSSpppiiinnnaaa 222PPP+++TTT 111666AAA 222555000VVV eee nnn...333 ppprrreeessseee bbbiiipppaaassssssooo 111000///111666AAA+++nnn...333 sssccchhhuuukkkooo cccooonnn iiinnnttteeerrrrrruuuttt tttooorrreee llluuummmiiinnnooosssooo
AAAVVVCCC222BBB111SSS///222000(((111222))) AAAvvvvvvooolllgggiiicccaaavvvooo ccciiivvviii llleee cccooonnn 222 ppprrreeessseee bbbiiipppaaassssssooo eeeddd 222 ppprrreeesssaaa sssccchhhuuukkkooo eee mmmttt ...222000 cccaaavvvooo HHH000555VVVVVV---FFF
Multiprese Civili: -Prese e spine civili; -Materiale in termoplastico antiurto e autoestinguente. -Alveoli e spinotti attivi protetti da contatti accidentali; Potenza massima prelevabile 2500W; -Confezione Pz.25.
32
RRRIIICCCAAAMMMBBBIII PPPEEERRR AAATTTTTTRRREEEZZZZZZAAATTTUUURRREEE CCCAAANNNTTTIIIEEERRREEE
IIINNNTTTEEERRRRRRUUUTTTTTTOOORRRIII MMMAAAGGGNNNEEETTTOOOTTTEEERRRMMMIIICCCIII MMMOOODDDUUULLLAAARRRIII --- SSSEEERRRIIIEEE IIIMMM
CODICE CORRENTE NOMINALE AMPERE (A)
POLI (P) MODULI DIN POTERE DI
INTERRUZIONE
III MMM CCC666 666 111+++NNN 1 4,5 kA III MMM CCC111000 111000 111+++NNN 1 4,5 kA
III MMM CCC111666 111666 111+++NNN 1 4,5 kA
III MMM CCC222555 222555 111+++NNN 1 4,5 kA
III MMM CCC333222 333222 111+++NNN 1 4,5 kA
III MMM 222///666 666 222 2 6,0 kA III MMM 222///111000 111000 222 2 6,0 kA
III MMM 222///111666 111666 222 2 6,0 kA
III MMM 222///222555 222555 222 2 6,0 kA
III MMM 222///333222 333222 222 2 6,0 kA
III MMM 333///111666 111666 333 3 6,0 kA
III MMM 333///222555 222555 333 3 6,0 kA
III MMM 333///333222 333222 333 3 6,0 kA
III MMM 333///666333 666333 333 3 6,0 kA
III MMM 444///111666 111666 444 4 6,0 kA
III MMM 444///222555 222555 444 4 6,0 kA
III MMM 444///333222 333222 444 4 6,0 kA
III MMM 444///666333 666333 444 4 6,0 kA
III MMM 444///888000 888000 444 6 10,0 kA
III MMM 444///111000000 111000000 444 6 10,0 kA
III MMM 444///111222555 111222555 444 6 10,0 kA
Serie di interruttori magnetotermici Utilizzabili per la protezione di apparecchiature e linee elettriche da corto circuiti o sovraccarichi di corrente Settore di utilizzo: civile,terziario. Caratteristiche Tecniche :
• da 2 Poli interrotti di cui uno protetto e l’altro sezionato sino a 4 poli protetti;
• Curva di intervento : C
• Potere di interruzione : 4,5 kA – 6 – 10 kA
• Tensione di esercizio 220-240V. – 380/440V. 50-60 Hz.
• Resistenza Meccanica : Oltre 20000 operazioni
• Conforme CE , Conforme IEC 60898
33
DDDIIIFFFFFFEEERRREEENNNZZZIIIAAALLLIII PPPUUURRRIII --- SSSEEERRRIIIEEE IIIDDD
CODICE CORRENTE NOMINALE AMPERE (A)
POLI (P) MODULI DIN SENSIBILITA’
mA
III DDD222///222555///333000000 222555 222 2 300 III DDD222///222555///333000 222555 222 2 30 III DDD222///444000///333000000 444000 222 2 300 III DDD222///444000///333000 444000 222 2 30 III DDD444///444000///333000000 444000 444 4 300 III DDD444///444000///333000 444000 444 4 30 III DDD444///666333///333000000 666333 444 4 300 III DDD444///666333///333000 666333 444 4 30
III DDD444///111000000///333000000 111000000 444 4 300 III DDD444///111000000///333000 111000000 444 4 30 III DDD444///111222555///333000000 111222555 444 4 300
Serie di interruttori differenziali puri da 2 o 4 moduli DIN Utilizzabili per la protezione di apparecchiature e linee elettriche , guasti a terra, realizzano la protezione delle persone contro i contatti indiretti. Settore di utilizzo: civile,terziario. Caratteristiche Tecniche :
• 2 o 4 Poli(impianti monofase o impianti trifase);
• Ingombro 2P 2 moduli DIN – 4P 4 moduli din
• Classe di impiego : AC -A
• Amperaggi 40A – 63A -100A – (30 - 300 mA)
• Temperature di funzionamento : -55°C/+60°C
• Tensione di esercizio 240V-415V 50-60 Hz.
• Resistenza Meccanica : Oltre 15000 operazioni
• Conforme CE , Conforme IEC 1008.1
34
AAACCCCCCEEESSSSSSOOORRRIII,,, SSSAAALLLVVVAAAMMMOOOTTTOOORRRIII ,,, LLLAAAMMMPPPAAADDDEEE,,, EEECCCCCC...
FFFIIIGGG... 111 FFFIIIGGG...222 FFFIIIGGG...333 FFFIIIGGG...444
FFFIIIGGG... 555 FFFIIIGGG... 666 FFFIIIGGG... 777 FFFIIIGGG...888
ACCESSORI PER PONTEGGIO E LUCI PONTEGGIO
CODICE DESCRIZIONE
SPL(fig.4) GANCIO IN PLASTICA PER LP AGGANCIO A PONTEGGIO ∅∅∅∅ 50 mmq.
LAM10W(fig.2) LAMPADA ATTACCO E 14 24V 10W PER LUCI PONTEGGIO
LP(fig.3) PLAFONIERA PER PONTEGGI
MST(fig.5) MORSETTO IN ZAMA ZINCATA PER SCARICO A T ERRA
C1G16G/V CORDA IN PVC GIALLO/VERDE 16mmq PER MESSA A TERRA MT.100
PT(fig.6) PICCHETTO DI TERRA L=1,5 MT.
PE/Q PULSANTE DI EMERGENZA PER QUADRI ACCESSORI PER SALVAMOTORI
PE/SM(fig.7) PULSANTE DI EMERGENZA PER SALVAMOTORE CON CORNICE
BMF o BTF(fig.1) BOBINA DI MINIMA TENSIONE 230V o 400V PER SM
SM(fig.10) SALVAMOTORE MAGNETOTERMICO TARATURA 6,3- 10A o 10-16A ACCESSORI PER PROIETTORI ALOGENI
LAM1500W LAMPADA ALOGENA 230V 1000W PER PROIETTORI ALOGENI
LAM1000W LAMPADA ALOGENA 230V 500W PER PROIETTORI ALOGENI
LAM500W LAMPADA ALOGENA 230V 500W PER PROIETTORI ALOGENI
35
CONDIZIONI GENERALI DI VENDITA:
Sconti applicati per Categoria : Sconto Rivenditore di Materiale - Attrezzature Edili : Sconto Grossista di Attrezzatura Edile : Sconto Produttore di Macchine Edili: Sconto Rivenditore di Materiale Elettrico:
Condizioni di pagamento : In caso di ritardo di pagamento alle scadenze pattu ite e agli importi concordati, saranno addebitati gli interessi passivi, con maggiorazione di 3 punti.
Trasporto : Mediante corriere di nostra fiducia in Porto Franco con addebito in fattura per ordini inferiori a € 1.000 netti.
Importo minimo : Ordini di importo netto inferiori a € 300,00 non sa ranno evasi.
Imballo : Imballo standard in cartoni, gratuito per ordini di importo superiori a € 300,00 netti.
Prezzi : I prezzi indicati in questo listino sono da ritener si non impegnativi. La ditta S.M.E.I. si riserva la possibilità di apportare variazioni senz a preavviso per adeguamento costi (variante rame su cavi, prolunghe e Avvolgicavo).Infatti per quanto attiene avvolgicavo, prolunghe e tutto quanto necessiti una quantità superiore ai 5 mt. di cavo Neoprene(H07RN-F) è sempre utile chiedere la quotazione del prodotto in ditta per i motivi sopra citati.
Offerte : Le offerte o i prezzi netti che verranno indicati d urante i mesi dell’anno sono da ritenersi validi per la sola fornitura proposta in quella offerta. Tutti i prodotti del nostro catalogo sono garantiti per dodici mesi, la garanzia non prevede l’usura dovuta all’utilizzo, guasti per errato mont aggio ed utilizzo ed è escluso il risarcimento per danno diretto o indiretto
Note importanti
La S.M.E.I. S.a.s. si riserva la facoltà di cambiar e in qualsiasi momento e senza preavviso il presente listino e di modificare se necessario i pr odotti per una maggiore qualità.
I prodotti compresi e schematizzati nel presente li stino sono quelli di uso più comune; a richiesta si possono fornire prodotti di ogni tipo e per qualsiasi impiego con quotazione sempre da richiedere in ditta.