L
Miniature circuit breakers
Residential current circuit breakers
Busbar systems
Comfort functions/Energy control
Residential enclosures
Contactors/Soft starters/Speed drives
Overload relays
Control and signalling units
Manual motor starters
Moulded case circuit breakers
Air circuit breakers
Fuse systems/Loadbreak disconnectors
General purpose enclosures
System enclosures
Numerical index
Series Mbs25Accessories for series Mbs25
Series Mbs32Series Ms32
Series Mbs63Series Ms63
Auxiliaries for series Mbs32/63Accessories for series Mbs32/63
Enclosures for series Mbs32/63
Coordination tables for fuseless starters
I.2I.3
I.5I.6
I.7I.8
I.9I.11
I.12
I.14
I
J
Manual motor starters
I
Man
ual
mot
or s
tart
ers
I.2
b-relaesesetting range
[A]
0.1 - 0.160.16- 0.250.25 - 0.4
0.4 - 0.630.63 - 1.01.0 - 1.6
1.6 - 2.52.5 - 44 - 6.3
6.3 - 1010 - 1616 - 2020 - 25
Icu[kA]
656565
656565
656565
10666
Ics[kA]
656565
656565
6565
37.5
5333
max. fuse(gL/gG) [kA]
(1)(1)(1)
(1)(1)(1)
(1)(1)(1)
80808080
Icu[kA]
656565
656565
651010
4444
Ics [kA]
656565
656565
6555
2222
max. fuse(gL/gG) [kA]
(1)(1)(1)
(1)(1)(1)
(1)3550
80808080
Icu[kA]
656565
656565
101010
43.52.52.5
Ics [kA]
656565
656565
555
21.71.21.2
max. fuse(gL/gG) [kA]
(1)(1)(1)
(1)(1)(1)
253550
80808080
Icu[kA]
656565
656565
333
33
1.51.5
Ics [kA]
656565
656565
1.51.51.5
1.51.50.70.7
max. fuse(gL/gG) [kA]
(1)(1)(1)
(1)(1)(1)
253550
50636363
Icu[kA]
424242
4211
111
1111
Ics [kA]
424242
4211
0.50.50.5
0.50.50.50.5
max. fuse(gL/gG) [kA]
(1)(1)(1)
(1)2020
202535
35355050
230 V 400 V 415 V 500 V 690 V
Short-circuit breaking capacity acc. to IEC 947-2
Short-circuit breaking capacity acc. to IEC 947-2
b-relaese [A]
0.1 - 0.160.16 - 0.250.25 - 0.40.4 - 0.630.63 - 11 - 1.61.6 - 2.52.5 - 44 - 6.36.3 - 1010 - 1616 - 2020 - 25
0.1 - 0.160.16 - 0.250.25 - 0.40.4 - 0.630.63 - 11 - 1.61.6 - 2.52.5 - 44 - 6.36.3 - 1010 - 1616 - 2020 - 25
s-relaese [A]
1.934.87.51219304875120190240300
3.45.58.81321335680120190300390390
Pack.
1111111111111
1111111111111
Series Mbs25
Basic breaker without auxiliary switches
Version for transformer without auxiliary switches
Motor protective circuit breaker Mbs25
Short-circuit breaking capacityIn [A]
< 2.5< 6.3< 25
Icu[A]
656550
Ics[A]
656550
Icu[A]
655050
Ics[A]
655050
Motor protective circuit breaker Mbs25 + Rapid module id50
(1) No fuse necessary up to the indicated current values of Icu bzw. Ics. If the short circuit current is higher than the short-circuit breaking capacity, it is necessary to use a fuse. To increase the short circuit breaking capacity, the manual motor starter Mbs25 can be combined with the limitor type id 50. Following are the values for the short-circuit capacity with this combinaton:
230 V 400 V
Cat. No.
Mbs25-001Mbs25-002Mbs25-004Mbs25-006Mbs25-010Mbs25-016Mbs25-025Mbs25-040Mbs25-063Mbs25-100Mbs25-160Mbs25-200Mbs25-250
Mbs25-001TMbs25-002TMbs25-004TMbs25-006TMbs25-010TMbs25-016TMbs25-025TMbs25-040TMbs25-063TMbs25-100TMbs25-160TMbs25-200TMbs25-250T
Ref. No.
254168254174254180254189254198254209254220254231254244254256254266254275254282
254169254175254183254191254200254212254222254234254247254258254268254276254284
Manual motor starters
I
I.3
Series Mbs25
Description
For side mounting 1NO, 1NC2NO1NO (early make), 1NC2NO (early make)
To increase contact reliability with small voltages 4 - 30V and 4 - 100mA, 1 C/O
For internal mounting 1NO, 1NC
For internal mounting 1NO1NC
For side mounting Complete with through PE and N conductors Wiring cross section 0.75 - 2.5mm2
For internal mounting AC 220/230V 50Hz, 240V 60HzAC 380/400V 50Hz, 440V 60HzAC 110V 50Hz, 120V 60Hz
For side mounting 4 terminals for a- or r-release
For internal mounting AC 220/230V 50Hz, 240V 60HzAC 380/400V 50Hz, 440V 60HzAC 110V 50Hz, 120V 60Hz
For individual or group protection increases the breaking capacity of the Mbs25 up to Icu 42kA/3~ 400 V; Iu = 32A in combination with Mbs25
Fully insulated, Ui = 690 V; Iu = 63 A, for Mbs25 with HS 9 with 2 devices 3-phase, 99mm longwith 3 devices 3-phase, 154mm longwith 4 devices 3-phase, 208mm longwith 5 devices 3-phase, 262mm long
Cat. No.
HS 9.11-Mbs25HS 9.20-Mbs25HS 9V.11-Mbs25HS 9V.20-Mbs25
HS 9K.001-Mbs25
HS 10.11-Mbs25
HS10R.10-Mbs25HS10R.01-Mbs25
PE/N-Mbs25
a51-Mbs25a52-Mbs25a53-Mbs25
KPS-Mbs25
r51-Mbs25r52-Mbs25r53-Mbs25
id50-Mbs25
d21-Mbs25d31-Mbs25d41-Mbs25d51-Mbs25
Ref. No.
254488254495254499254502
254519
254515
254504254511
254459
254413254414254415
254460
254396254397254398
254525
254540254545254533254535
Pack.
1111
1
1
11
1
111
1
111
1
1111
Accessories for series Mbs25
Aux. switch block type HS 9
Aux. switch block type HS 10
Trip indication switch type HS 10R
PE- and Neutral conductor block
Shunt trip type a
Terminal clamps
Undervoltage release type r
Rapid-Module type id 50
3 phase insulated busbar section type d
Manual motor starters
I
Man
ual
mot
or s
tart
ers
I.4
Description
3-pole for unused busbar terminations
Fully insulated, U i = 690 V; I u = 63 A 3-pole for 3-phase insulated busbar section type d
Surface mounting Protection degree IP41Protection degree IP55Kit IP 55 for enclosure IP41
Especially for the American and Canadian market Protection grade IP 55 with NPT-threads 2 x 1/2” and 2 x 3/4”
Flush mounting Protection degree IP41Protection degree IP55Kit IP 55 for front plate IP41
For enclosure and front plate
For enclosure IP41 and front plate (colour yellow) for 3 padlocks in the OFF position
For enclosure IP41 and front plate IP41 Mushroom head latched, pull to release
For enclosure IP41 and front plate IP41, protection degree IP55, red pushbutton with yellow backplate
Mushroom head key lockable (fact. ass.), release with key
For enclosure IP41 and front plate IP41 Mushroom head transient
Cat. No.
d-BSK
db
i41i55
i-IP41/55
gi55
it41it55
it-IP41/55
i/it-N
i/it-SV
i/it-PTZ
i/it-PTS
i/it-PTT
Ref. No.
254542
254537
254430254435254452
254522
254441254445254455
254449
254422
254424
254427
254428
Pack.
1
1
111
1
111
1
1
1
1
1
Accessories for series Mbs25
Protective cover
Terminal block type db
Moulded enclosure type i
Enclosure type gi
Moulded front plate type it
Neutral conductor
Padlocking device
Emergency OFF device
I
I.5
Series Mbs32
Thermal and magnetic motor protection circuit breakers
CLASS 10
CLASS 10Rated power
3 phase motors at 400Vac Pn
kW
0.020.060.09
0.12/0.180.25
0.37/0.550.751.52.23/45.57.5101115
Ratedcurrent
In(1)
A
0.160.250.40.63
11.62.54
6.3101316202532
Thermalcurrent
setting range
A
0.1 - 0.160.16 - 0.250.25 - 0.40.4 - 0.630.63 - 11 - 1.6
1.6 - 2.52.5 - 44 - 6.3
6.3 - 109 - 1311 - 1614 - 2019 - 2524 - 32
Rated power 3 phase motors
at 400Vac Pn
kW
0.020.060.09
0.12/0.180.25
0.37/0.550.751.52.23/45.57.5101115
Ratedcurrent
In(1)
A
0.160.250.40.63
11.62.54
6.3101316202532
Thermalcurrent
setting range
A
0.1 - 0.160.16 - 0.250.25 - 0.40.4 - 0.630.63 - 11 - 1.6
1.6 - 2.52.5 - 44 - 6.3
6.3 - 109 - 1311 - 1614 - 2019 - 2524 - 32
Instantaneous short-circuit
release
A
2.13.35.28.213
20.832.552
81.9130169208260325416
Rated ultimateshort-circuit
breakingcapacity at 400V
Icu kA
10010010010010010010010010010010050505050
Rated serviceshort-circuit
breaking capacity at 400VIcs kA
10010010010010010010010010010010038383838
Cat. No.
Mbs32HG001Mbs32HG002Mbs32HG004Mbs32HG006Mbs32HG010Mbs32HG016Mbs32HG025Mbs32HG040Mbs32HG063Mbs32HG100Mbs32HG130Mbs32HG160Mbs32HG200Mbs32HG250Mbs32HG320
Ref. No.
107419107420107421107422107423107424107425107426107427107428107429107430107431107432107433
Pack.
555555555555555
Series Mbs32 - High breaking capacity
Pack.
555555555555555
Ref. No.
107395107396107397107398107399107400107401107402107403107404107405107406107407107408107409
Cat. No.
Mbs32SG001Mbs32SG002Mbs32SG004Mbs32SG006Mbs32SG010Mbs32SG016Mbs32SG025Mbs32SG040Mbs32SG063Mbs32SG100Mbs32SG130Mbs32SG160Mbs32SG200Mbs32SG250Mbs32SG320
Rated serviceshort-circuit
breaking capacity at 400VIcs kA
1001001001001001001001001001003819191919
Rated ultimateshort-circuit
breaking capaci-ty at 400V
Icu kA
1001001001001001001001001001005025252525
Instantaneous short-circuit
release
A
2.13.35.28.213
20.832.552
81.9130169208260325416
Series Mbs32 - Standard breaking capacity
(1) Rated current: highest thermal current setting range value.
(1) Rated current: highest thermal current setting range value.
I
Man
ual
mot
or s
tart
ers
I.6
Magnetic motor protection circuit breakers
Rated power 3 phase
motors at 400Vac Pn
kW
0.020.060.09
0.12/0.180.25
0.37/0.550.751.52.23/45.57.5101115
Rated current In
A
0.160.250.40.63
11.62.54
6.3101316202532
Thermalcurrent
setting range(1)
A
---------------
Instantaneous short-circuit
release
A
2.13.35.28.213
20.832.552
81.9130169208260325416
Rated ultimateshort-circuit
breakingcapacity at 400V
Icu kA
1001001001001001001001001001005025252525
Rated serviceshort-circuit
breaking capacity at 400V
Ics kA
1001001001001001001001001001003819191919
Cat. No.
Ms32SG001Ms32SG002Ms32SG004Ms32SG006Ms32SG010Ms32SG016Ms32SG025Ms32SG040Ms32SG063Ms32SG100Ms32SG130Ms32SG160Ms32SG200Ms32SG250Ms32SG320
Ref. No.
107443107444107445107446107447107448107449107450107451107452107453107454107455107456107457
Pack.
555555555555555
Series Mss32 - Standard breaking capacity
Rated power 3 phase
motors at 400Vac Pn
kW
0.020.060.09
0.12/0.180.25
0.37/0.550.751.52.23/45.57.5101115
Rated current In
A
0.160.250.40.63
11.62.54
6.3101316202532
Thermalcurrent set-ting range
(1)
A
---------------
Instantaneous short-circuit
release
A
2.13.35.28.213
20.832.552
81.9130169208260325416
Rated ultimateshort-circuit
breaking capaci-ty at 400V
Icu kA
10010010010010010010010010010010050505050
Rated serviceshort-circuit
breaking capaci-ty at 400V
Ics kA
10010010010010010010010010010010038383838
Cat. No.
Ms32HG001Ms32HG002Ms32HG004Ms32HG006Ms32HG010Ms32HG016Ms32HG025Ms32HG040Ms32HG063Ms32HG100Ms32HG130Ms32HG160Ms32HG200Ms32HG250Ms32HG320
Ref. No.
107467107468107469107470107471107472107473107474107475107476107477107478107479107480107481
Pack.
555555555555555
Series Mss32 - High breaking capacity
(1) Select appropriate thermal overload relay for the starter. See chapter G, pages G.3-G.6
(1) Select appropriate thermal overload relay for the starter. See chapter G, pages G.3-G.6
I
I.7
Series Mbs63
CLASS 10 Series Mbs63 - High breaking capacity
Thermal and magnetic motor protection circuit breakers
Rated power 3 phase
motors at 400Vac Pn
kW
3/45.57.5101115
18.52230
Ratedcurrent
In(1)
A
101316202532405063
Thermalcurrent setting
range
A
6.3 - 109 - 1311 -1614 - 2019 - 2524 - 3228 - 4035 - 5045 - 63
Instantaneous short-circuit
release
A
130169208260325416520650819
Rated ultimateshort-circuit
breaking capacity at 400VIcu kA
1002525252525252525
Rated serviceshort-circuit
breaking capacity at 400VIcs kA
1001919191919191919
Cat. No.
Mbs63SG100Mbs63SG130Mbs63SG160Mbs63SG200Mbs63SG250Mbs63SG320Mbs63SG400Mbs63SG500Mbs63SG630
Ref. No.
107410107411107412107413107414107415107416107417107418
Pack.
111111111
Rated power 3 phase
motors at 400Vac Pn
kW
3/45.57.5101115
18.52230
Ratedcurrent
In(1)
A
101316202532405063
Thermal current setting
range
A
6.3 - 109 - 1311 -1614 - 2019 - 2524 - 3228 - 4035 - 5045 - 63
Instantaneous short-circuit
release
A
130169208260325416520650819
Rated ultimateshort-circuit
breaking capacity at 400VIcu kA
1005050505050505050
Rated serviceshort-circuit
breaking capacity at 400VIcs kA
1003838383838383838
Cat. No.
Mbs63HG100Mbs63HG130Mbs63HG160Mbs63HG200Mbs63HG250Mbs63HG320Mbs63HG400Mbs63HG500Mbs63HG630
Ref. No.
107434107435107436107437107438107439107440107441107442
Pack.
111111111
(1) Rated current: highest thermal current setting range value.
CLASS 10 Series Mbs63 - Standard breaking capacity
(1) Rated current: highest thermal current setting range value.
I
Man
ual
mot
or s
tart
ers
I.8
Magnetic motor protection circuit breakers
Rated power 3 phase
motors at 400Vac Pn
kW
3/45.57.5101115
18.52230
Ratedcurrent In
A
101316202532405063
Thermalcurrent setting
range(1)
A
---------
Instantaneous short-circuit
release
A
130169208260325416520650819
Rated ultimateshort-circuit
breaking capacity at 400VIcu kA
1002525252525252525
Rated serviceshort-circuit
breaking capacity at 400VIcs kA
1001919191919191919
Cat. No.
Ms63SG100Ms63SG130Ms63SG160Ms63SG200Ms63SG250Ms63SG320Ms63SG400Ms63SG500Ms63SG630
Ref. No.
107458107459107460107461107462107463107464107465107466
Pack.
111111111
Rated power 3 phase
motors at 400Vac Pn
kW
3/45.57.5101115
18.52230
Ratedcurrent In
A
101316202532405063
Thermalcurrent setting
range(1)
A
---------
Instantaneous short-circuit
release
A
130169208260325416520650819
Rated ultimateshort-circuit
breaking capacity at 400VIcu kA
1005050505050505050
Rated serviceshort-circuit
breaking capacity at 400VIcs kA
1003838383838383838
Cat. No.
Ms63HG100Ms63HG130Ms63HG160Ms63HG200Ms63HG250Ms63HG320Ms63HG400Ms63HG500Ms63HG630
Ref. No.
107482107483107484107485107486107487107488107489107490
Pack.
111111111
Series Ms63 - Standard breaking capacity
Series Ms63 - High breaking capacity
(1) Select appropriate thermal overload relay for the starter. See chapter G, pages G.3-G.6
(1) Select appropriate thermal overload relay for the starter. See chapter G, pages G.3-G.6
I
I.9
Mbs32/63
Auxiliaries for series Mbs32/63
Description
Maximum 2 auxiliary contact blocks per manual motor starter
Two contactsSide mounting on the left
Two contactsSide mounting on the right
Description
Frontal mounting on the right Single contact
Description
Side mounting on the left(front alarm contact block can
not be used at the same time)Two contacts
Description
Side mounting on the left Two contacts NO + NC Mechanical indication marking
For use with
M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...
M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...
M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...
For use with
M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...
For use with
M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...
For use with
M(b)s32... and M(b)s63...
Type
1 NO1 NC
1 NO + 1 NC2 NO2 NC
1 NO + 1 NC2 NO2 NC
Type
1 NO1 NC
Type
1 NO (Alarm) + 1 NO (Aux.)1 NO (Alarm) + 1 NC (Aux.)1 NC (Alarm) + 1 NO (Aux.)1 NC (Alarm) + 1 NC (Aux.)
Type
1 NO + 1 NC
Cat. No.
MAHS10FBMAHS01FB
MAHS11LLMAHS20LLMAHS02LL
MAHS11LRMAHS20LRMAHS02LR
Cat. No.
MAHSb10FRMAHSb01FR
Cat. No.
MAHSd1010LLMAHSd1001LLMAHSd0110LLMAHSd0101LL
Cat. No.
MAHSs11LL
Ref. No.
136160136161
136162136163136164
136165136166136167
Ref. No.
136157136158
Ref. No.
136168136169136170136171
Ref. No.
136172
Pack.
55
101010
101010
Pack.
55
Pack.
10101010
Pack.
10
Auxiliary contact blocks
Frontal
Lateral
Auxiliary contact blo Alarm contact block
Auxiliary contact blo Auxiliary / alarm contact block
Short-circuit alarm contact block
I
Man
ual
mot
or s
tart
ers
I.10
Auxiliaries for series Mbs32/63
Description
Side mounting on the right Can not be used together with the undervoltage trip device
Description
Side mounting on the right Can not be used together with the shunt trip device
Side mounting on the right Can not be used together with the shunt trip device
Side mounting on the right Can not be used together with the shunt trip device
Description
Protection against accidental fi nger touch (IP20) for GPS2 manual motor starters
For use with
M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...
For use with
M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...M(b)s32... and M(b)s63...
M(b)s32*S...M(b)s32*S...M(b)s32*S...M(b)s32*S...M(b)s32*S...M(b)s32*S...M(b)s32*S...M(b)s32*S...M(b)s32*S...M(b)s32*S...M(b)s32*S...
M(b)s32H and M(b)s63...M(b)s32H and M(b)s63...M(b)s32H and M(b)s63...M(b)s32H and M(b)s63...M(b)s32H and M(b)s63...M(b)s32H and M(b)s63...M(b)s32H and M(b)s63...M(b)s32H and M(b)s63...M(b)s32H and M(b)s63...M(b)s32H and M(b)s63...M(b)s32H and M(b)s63...
For use with
M(b)s63..
Coil voltage
24V 50/60Hz48V 60Hz
48V 50Hz / 60V 60Hz110/127V 50Hz / 120V 60Hz
208V 60Hz220/230V 50Hz / 240/260V 60Hz
240V 50Hz / 277V 60Hz380/400V 50Hz
415/440V 50Hz / 460/480V 60Hz500V 50Hz / 600V 60Hz
24 to 60Vdc110 to 240Vdc
Coil voltage
24V 50Hz24V 60Hz48V 50Hz48V 60Hz
110/127V 50Hz / 120V 60Hz208V 60Hz
220/230V 50Hz / 240/260V 60Hz240V 50Hz / 277V 60Hz
380/400V 50Hz415/440V 50Hz / 460/480V 60Hz
500V 50Hz / 600V 60Hz
24V 50Hz24V 60Hz48V 50Hz48V 60Hz
110/127V 50Hz / 120V 60Hz208V 60Hz
220/230V 50Hz / 240/260V 60Hz240V 50Hz / 277V 60Hz
380/400V 50Hz415/440V 50Hz / 460/480V 60Hz
500V 50Hz / 600V 60Hz
24V 50Hz24V 60Hz48V 50Hz48V 60Hz
110/127V 50Hz / 120V 60Hz208V 60Hz
220/230V 50Hz / 240/260V 60Hz240V 50Hz / 277V 60Hz
380/400V 50Hz415/440V 50Hz / 460/480V 60Hz
500V 50Hz / 600V 60Hz
Cat. No.
MAaLRA1MAaLRAFMAaLRAGMAaLRAJMAaLRAMMAaLRANMAaLRARMAaLRAUMAaLRAWMAaLRAYMAaLRDDMAaLRDJ
Cat. No.
MArLRADMArLRACMArLRAGMArLRAFMArLRAJMArLRAMMArLRANMArLRARMArLRAUMArLRAWMArLRAY
MAr20LTADMAr20LTACMAr20LTAGMAr20LTAFMAr20LTAJMAr20LTAMMAr20LTANMAr20LTARMAr20LTAUMAr20LTAWMAr20LTAY
MAr20LCADMAr20LCACMAr20LCAGMAr20LCAFMAr20LCAJMAr20LCAMMAr20LCANMAr20LCARMAr20LCAUMAr20LCAWMAr20LCAY
Cat. No.
MAPTP63
Ref. No.
136173136174136175136176136177136178136179136180136181136182136183136184
Ref. No.
136185136186136187136188136189136190136191136192136193136194136195
136196136197136198136199136200136201136202136203136204136205136206
136207136208136209136210136211136212136213136214136215136216136217
Ref. No.
107183
Pack.
555555555555
Pack.
55555555555
55555555555
55555555555
Pack.
50
Shunt trip device
Undervoltage trip device
With 2NO early make auxiliary contacts
Terminal protector
I
I.11
Mbs32/63
Accessories for series Mbs32/63
Description
Used for distance mounting on a panel
Lockable with 1, 2 or 3 padlocks diameter 4 to 8 mmTwo types: standard and emergency applicationsON/OFF/TRIPPING position markingProtection degree: IP55Shaft mounting depths: 139.8 - 289.8 mm for MA32HB, MA32HR161 - 311.1 mm for MA63HB, MA63HRPackage parts and quantities:1 handle unit1 shaft1 shaft guide1 latch (screws)4 mounting screws
For use with
M(b)s32*H...M(b)s32*H ...
M(b)s63...M(b)s63 ...
Type
Standard (black)Emergency (red/yellow)
Standard (black)Emergency (red/yellow)
Cat. No.
MA32HBMA32HRMA63HBMA63HR
Ref. No.
136218136219136220136221
Pack.
5555
Description
Main feeding terminal Upper connection
Modular spacing 45 mm
Modular spacing 54 mm
Modular spacing 63 mm
Modular spacing 55 mm
Modular spacing 64 mm
Modular spacing 73 mm
Touch guard for non used space
For use with
M(b)s32...M(b)s63...
for 2 M(b)s32... + frontal auxiliariesfor 3 M(b)s32... + frontal auxiliariesfor 4 M(b)s32... + frontal auxiliariesfor 5 M(b)s32... + frontal auxiliaries
for 2 M(b)s32... + 9mm lateral auxiliaryfor 3 M(b)s32... + 9mm lateral auxiliaryfor 4 M(b)s32... + 9mm lateral auxiliaryfor 5 M(b)s32... + 9mm lateral auxiliary
for 2 M(b)s32... + 18mm lateralauxiliary or 2 x 9mm lateral auxiliary
for 4 M(b)s32... + 18mm lateralauxiliary or 2 x 9mm lateral auxiliary
for 2 M(b)s63... + frontal auxiliariesfor 3 M(b)s63... + frontal auxiliariesfor 4 M(b)s63... + frontal auxiliaries
for 2 M(b)s63... + 9mm lateral auxiliaryfor 3 M(b)s63... + 9mm lateral auxiliaryfor 4 M(b)s63... + 9mm lateral auxiliary
for 2 M(b)s63... + 18mm lateralauxiliary or 2 x 9mm lateral auxiliary
for 4 M(b)s63... + 18mm lateralauxiliary or 2 x 9mm lateral auxiliary
M(b)s32…M(b)s63…
Connection
Terminal capacity: 25 mm2
Terminal capacity: 50 mm2
PinPinPinPin
PinPinPinPin
Fork
Fork
PinPinPin
PinPinPin
Pin
Pin
--
Cat. No.
Md32FMd63F
Md32B02Md32B03Md32B04Md32B05
Md32B12Md32B13Md32B14Md32B15
Md32B22
Md32B24
Md63B02Md63B03Md63B04
Md63B12Md63B13Md63B14
Md63B22
Md63B24
Md32GMd63G
Ref. No.
107188107189
107035107036107037107038
107039107040107041107042
107043
107044
107045107046107047
107048107049107050
107051
107052
107054 107055
Pack.
101
5555
5555
10
10
111
111
1
1
1010
External handle operator
Busbar system
3-phase feed-in terminals
Main busbar
Busbar cover
I
Man
ual
mot
or s
tart
ers
I.12
Enclosures for series Mbs32/63
Description
Surface mounting IP41Surface mounting IP55
Flush mounting IP41Flush mounting IP55
Description
To be used inside the enclosure
For enclosures used with M(b)s32*SG and undervoltage release with 2 NO auxiliary contacts
For three padlocks with max. 8 mm shackle diameter Not to be used with emergency stop handle
Mushroom with impulse functionsMushroom self latching, unlatching by turningMushroom self latching, unlatching with a key
Green 110/220VGreen 220/240VGreen 380/440VGreen 480/500VGreen 600VRed 110/220VRed 220/240VRed 380/440VRed 480/500VRed 600VTransparent 110/220VTransparent 220/240VTransparent 380/440VTransparent 480/500VTransparent 600V
Cat. No.
Mi41Mi55
MiT41MiT55
Cat. No.
MiN
MiAS
MiD
MiC
MiPMMiPLMiPK
MiLGJMiLGNMiLGUMiLGXMiLGYMiLRJMiLRNMiLRUMiLRXMiLRYMiLCJMiLCNMiLCUMiLCXMiLCY
Ref. No.
136222136223
136224136225
Ref. No.
136226
107108
136227
136228
136229136230136231
136232136233136234136235136236136237136238136239136240136241136242136243136244136245136246
Pack.
11
11
Pack.
1
1
1
1
111
111111111111111
Enclosures for M(b)s32SG
Plastic enclosures
Accessories for enclosures
Neutral connection
Adaptor set
Padlocking device
Conversion kit IP41 to IP55
Emergency mushroom push-button
Indicator lamps
I
I.13
Mbs32/63
Manual motor starters - Coordination tables
Rated power
0.060.090.120.180.250.370.550.751.11.52.234
5.57.511151115
18.52230
380/400V
0.230.340.440.650.9
1.251.62
2.63.55791216
22.530
22.530374460
Rated current
(A)415V
0.210.310.40.630.81.11.51.92.53.44.56.58
111421282128354155
Minimum frontal
electrical safetyclearance
(mm)
20202020202020202020202020202020202020202525
Smallest wireCu
(PVC)(2)
380/415V(mm2)
11111111111
1.51.52.52.54646101016
Magneticcurrent
(A)
3.25.28.21313
20.520.532.5525282130130169208325416325416520650820
Ratedcurrent
In
(A)
0.250.4
0.6311
1.61.62.544
6.31010131625322532405063
Cat. No.
Mbs32SG002Mbs32SG004Mbs32SG006Mbs32SG010Mbs32SG010Mbs32SG016Mbs32SG016Mbs32SG025Mbs32SG040Mbs32SG040Mbs32SG063Mbs32SG100Mbs32SG100Mbs32HG130Mbs32HG160Mbs32HG250Mbs32HG320Mbs63HG250Mbs63HG320Mbs63HG400Mbs63HG500Mbs63HG630
Thermalcurrent
Settingrange
(A)
0.16 - 0.250.25 - 0.40.4 - 0.630.63 - 10.63 - 11 - 1.61 - 1.6
1.6 - 2.52.5 - 42.5 - 44 - 6.3
6.3 - 106.3 - 109 - 1311 - 1619 - 2524 - 3219 - 2524 - 3228 - 4035 - 5045 - 63
Series
LS02K / LS4KLS02K / LS4KLS02K / LS4KLS02K / LS4KLS02K / LS4KLS02K / LS4KLS02K / LS4KLS02K / LS4KLS02K / LS4KLS02K / LS4KLS02K / LS4KLS05 / LS4KLS05 / LS4K
LS5KLS7KLS11KLS15KLS15KLS15KLS18KLS22KLS30K
Cat. No.(3)
MF32L05B/MF32L7*MF32L05B/MF32L7*MF32L05B/MF32L7*MF32L05B/MF32L7*MF32L05B/MF32L7*MF32L05B/MF32L7*MF32L05B/MF32L7*MF32L05B/MF32L7*MF32L05B/MF32L7*MF32L05B/MF32L7*MF32L05B/MF32L7*MF32L05B/MF32L7*MF32L05B/MF32L7*MF32L7*MF32L7*MF32L11*MF32L16*MF63L16*MF63L16*MF63L18*MF63L30AMF63L30A
MOTOR(1) MANUAL MOTOR STARTER CONTACTOR LINKS
Rated power
0.060.090.120.180.250.370.550.751.11.52.234
5.57.511151115
18.52230
380/400V
0.230.340.440.650.9
1.251.62
2.63.55791216
22.530
22.530374460
Rated current
(A)415V
0.210.310.40.630.81.11.51.92.53.44.56.58
111421282128354155
Minimum frontal
electrical safetyclearance
(mm)
20202020202020202020202020202020202020202525
Smallest wireCu
(PVC)(2)
380/415V(mm2)
11111111111
1.51.52.52.54646101016
Magneticcurrent
(A)
3.25.28.21313
20.520.532.5525282130130169208325416325416520650820
Ratedcurrent
In
(A)
0.250.4
0.6311
1.61.62.544
6.31010131625322532405063
Cat. No.
Mbs32HG002Mbs32HG004Mbs32HG006Mbs32HG010Mbs32HG010Mbs32HG016Mbs32HG016Mbs32HG025Mbs32HG040Mbs32HG040Mbs32HG063Mbs32HG100Mbs32HG100Mbs32HG130Mbs32HG160Mbs32HG250Mbs32HG320Mbs63HG250 (4)Mbs63HG320 (4)Mbs63HG400 (4)Mbs63HG500 (4)Mbs63HG630 (4)
Thermalcurrent
Settingrange
(A)
0.16 - 0.250.25 - 0.40.4 - 0.630.63 - 10.63 - 11 - 1.61 - 1.6
1.6 - 2.52.5 - 42.5 - 44 - 6.3
6.3 - 106.3 - 109 - 1311 - 1619 - 2524 - 3219 - 2524 - 3228 - 4035 - 5045 - 63
Series
LS4KLS4KLS4KLS4KLS4KLS4KLS4KLS4KLS11KLS11KLS11KLS11KLS11KLS11KLS11KLS11KLS15KLS15KLS15KLS18KLS22KLS30K
Cat. No.(3)
MF32L7*MF32L7*MF32L7*MF32L7*MF32L7*MF32L7*MF32L7*MF32L7*MF32L11*MF32L11*MF32L11*MF32L11*MF32L11*MF32L11*MF32L11*MF32L11*MF32L16*MF63L16*MF63L16*MF63L18*MF63L30AMF63L30A
MOTOR(1) MANUAL MOTOR STARTER CONTACTOR LINKS
(1) Currents are relevant to four pole motors not having special characteristics of torque. Inrush currents: 8 time rated current for 1s. (2) The minimum cycle cross-sections are referred to an ambient temperature of 30°C max. in free air.
Cables are to withstand the maximum let-through energy and the motor rated current. Besides the user should consider the drop voltage on the cables,the type of laying and the ambient temperature.
(3) Complete cat. nrs., see page I.13(4) Test running.
Coordination type 1 65kA at 380/400V and 415V
Coordination type 2 65kA at 380/400V and 415V
I
Man
ual
mot
or s
tart
ers
I.14
Manual motor starters - Coordination tables
Rated power
(kW)
0.060.090.120.180.250.370.550.751.11.52.234
5.57.5101115
18.51115
18.5223037
500V
0.170.240.330.480.660.91.21.52.12.83.95.36.89.112
15.517.623
28.517.623
28.5334553
Rated current
(A)525V
0.160.220.3
0.460.640.851.151.451.92.63.65
6.58.6
11.414.8172227172227
31.54352
Minimum frontal
electrical safetyclearance
(mm)
20202020202020202020202020202020202020202020202525
Smallest wireCu
(PVC)(2)
380/415V(mm2)
1111111111111
1.52.52.52.546
2.546
6/101016
Magneticcurrent
(A)
3.23.25.28.21313
20.520.532.5525282130130169208260325416260325416520650820
Ratedcurrent
In
(A)
0.250.250.40.63
11
1.61.62.544
6.310101316202532202532405063
Cat. No.
Mbs32SG002Mbs32SG002Mbs32SG004Mbs32SG006Mbs32SG010Mbs32SG010Mbs32SG016Mbs32SG016Mbs32SG025Mbs32SG040Mbs32SG040Mbs32SG063Mbs32HG100Mbs32HG100Mbs32HG130Mbs32HG160Mbs32HG200Mbs32HG250Mbs32HG320Mbs63HG200Mbs63HG250Mbs63HG320Mbs63HG400Mbs63HG500Mbs63HG630
Thermalcurrent
Settingrange
(A)
0.16 - 0.250.16 - 0.250.25 - 0.40.4 - 0.630.63 - 10.63 - 11 - 1.61 - 1.6
1.6 - 2.52.5 - 42.5 - 44 - 6.36.3 - 106.3 - 10 9 - 13 11 - 1614 - 2019 - 2524 - 3214 - 2019 - 2524 - 3228 - 4035 - 5045 - 63
Series
LS02K/LS4KLS02K/LS4KLS02K/LS4KLS02K/LS4KLS02K/LS4KLS02K/LS4KLS02K/LS4KLS02K/LS4KLS02K/LS4KLS02K/LS4KLS02K/LS4KLS02K/LS4KLS05/LS4K
LS4KLS5KLS7K
LS11KLS11KLS15KLS15KLS15KLS15KLS18KLS22KLS30K
Cat. No.(3)
MF32L05B/MF32L7* MF32L05B/MF32L7* MF32L05B/MF32L7* MF32L05B/MF32L7* MF32L05B/MF32L7* MF32L05B/MF32L7* MF32L05B/MF32L7* MF32L05B/MF32L7* MF32L05B/MF32L7* MF32L05B/MF32L7* MF32L05B/MF32L7* MF32L05B/MF32L7* MF32L05B/MF32L7* MF32L7* MF32L7* MF32L7* MF32L11* MF32L11* MF32L16* MF63L16* MF63L16* MF63L16* MF63L18* MF63L30A MF63L30A
MOTOR(1) MANUAL MOTOR STARTER CONTACTOR LINKS
Rated power
(kW)
0.060.090.120.180.250.370.550.751.11.52.234
5.57.5101115
18.51115
18.5223037
500V
0.170.240.330.480.660.91.21.52.12.83.95.36.89.112
15.517.623
28.517.623
28.5334553
Rated current
(A)525V
0.160.220.3
0.460.640.851.151.451.92.63.65
6.58.6
11.414.8172227172227
31.54352
Minimum frontal
electrical safetyclearance
(mm)
20202020202020202020202020202020202020202020252525
Smallest wireCu
(PVC)(2)
380/415V(mm2)
1111111111111
1.52.52.52.546
2.546
6/101016
Magneticcurrent
(A)
3.23.25.28.21313
20.520.532.5525282130130169208260325416260325416520650820
Ratedcurrent
In
(A)
0.250.250.40.63
11
1.61.62.544
6.310101316202532202532405063
Cat. No.
Mbs32S/HG002Mbs32S/HG002Mbs32S/HG004Mbs32S/HG006Mbs32S/HG010Mbs32S/HG010Mbs32S/HG016Mbs32S/HG016Mbs32S/HG025Mbs32S/HG040Mbs32S/HG040Mbs32S/HG063Mbs32HG100Mbs32HG100Mbs32HG130Mbs32HG160Mbs32HG200Mbs32HG250Mbs32HG320Mbs63HG200Mbs63HG250Mbs63HG320Mbs63HG400Mbs63HG500Mbs63HG630
Thermalcurrent
Settingrange
(A)
0.16 - 0.250.16 - 0.250.25 - 0.40.4 - 0.630.63 - 10.63 - 11 - 1.61 - 1.6
1.6 - 2.52.5 - 42.5 - 44 - 6.36.3 - 106.3 - 10 9 - 13 11 - 1614 - 2019 - 2524 - 3214 - 2019 - 2524 - 3228 - 4035 - 5045 - 63
Series
LS05/LS4KLS05/LS4KLS05/LS4KLS05/LS4KLS05/LS4KLS05/LS4KLS05/LS4KLS05/LS4K
LS5KLS11KLS11KLS11KLS11KLS11KLS11KLS11KLS11KLS15KLS15KLS15KLS15KLS18KLS22KLS22KLS30K
Cat. No.(3)
MF32L05B/MF32L7* MF32L05B/MF32L7* MF32L05B/MF32L7* MF32L05B/MF32L7* MF32L05B/MF32L7* MF32L05B/MF32L7* MF32L05B/MF32L7* MF32L05B/MF32L7* MF32L7* MF32L11* MF32L11* MF32L11* MF32L11* MF32L11* MF32L11* MF32L11* MF32L11* MF32L16* MF32L16* MF63L16* MF63L16* MF63L18* MF63L30A MF63L30A MF63L30A
MOTOR(1) MANUAL MOTOR STARTER CONTACTOR LINKS
(1) Currents are relevant to four pole motors not having special characteristics of torque. Inrush currents: 8 time rated current for 1s. (2) The minimum cycle cross-sections are referred to an ambient temperature of 30°C max. in free air.
Cables are to withstand the maximum let-through energy and the motor rated current. Besides the user should consider the drop voltage on the cables,the type of laying and the ambient temperature.
(3) Complete cat. nrs., see page I.13
Coordination type 1 50kA at 500V and 525V
Coordination type 2 50kA at 500V and 525V
I
I.15
Mbs32/63
Manual motor starters - Coordination tables
Rated power
0.060.090.120.180.250.370.550.751.11.52.234
5.57.57.511151115
18.5222230
Rated power
0.060.090.120.180.250.370.550.751.11.52.234
5.57.57.511151115
18.5222230
380/400V
0.230.340.440.650.9
1.251.62
2.63.557912-
1622.530
22.53037-
4460
380/400V
0.230.340.440.650.9
1.251.62
2.63.557912-
1622.530
22.53037-
4460
Rated current
(A)
Rated current
(A)
415V
0.210.310.40.630.81.11.51.92.53.44.56.58
1114-
212821283540-
55
415V
0.210.310.40.630.81.11.51.92.53.44.56.58
1114-
212821283540-
55
Setting range
0.16 - 0.260.25 - 0.410.4 - 0.650.4 - 0.650.65 - 1.1
1 - 1.51.3 - 1.91.8 - 2.72.5 - 42.5 - 44 - 6.3
5.5 - 8.58 - 12
10 - 1610 - 16
14.5 - 1821 - 2625 - 3221 - 2625 - 3230 - 4030 - 4342 - 5554 - 65
Setting range
0.16 - 0.260.25 - 0.410.4 - 0.650.4 - 0.650.65 - 1.1
1 - 1.51.3 - 1.91.8 - 2.72.5 - 42.5 - 44 - 6.3
5.5 - 8.58 - 12
10 - 1610 - 16
14.5 - 1821 - 2625 - 3221 - 2625 - 3230 - 4030 - 4342 - 5554 - 65
Minimum frontalsafety
clearance
(mm)
202020202020202020202020202020202020202020252525
Minimum frontalsafety
clearance
(mm)
202020202020202020202020202020202020202020252525
Series
b18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb55Kb55Kb55K
Series
b18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb18Kb55Kb55Kb55K
Magneticcurrent
(A)
3.35.28.21313
20.820.832.55252
81.9130130169208208325416325416520650650819
Magneticcurrent
(A)
3.35.28.21313
20.820.832.55252
81.9130130169208208325416325416520650650819
Ratedcurrent
In
(A)
0.250.4
0.6311
1.61.62.544
6.310101316162532253240505063
Ratedcurrent
In
(A)
0.250.4
0.6311
1.61.62.544
6.310101316162532253240505063
Cat. No.
Ms32S/HG002Ms32S/HG004Ms32S/HG006Ms32S/HG010Ms32S/HG010Ms32S/HG016Ms32S/HG016Ms32S/HG025Ms32S/HG040Ms32S/HG040Ms32S/HG063Ms32S/HG100Ms32S/HG100Ms32HG130Ms32HG160Ms32HG160Ms32HG250Ms32HG320Ms63HG250Ms63HG320Ms63HG400Ms63HG500Ms63HG500Ms63HG630
Cat. No.
Ms32S/HG002Ms32S/HG004Ms32S/HG006Ms32S/HG010Ms32S/HG010Ms32S/HG016Ms32S/HG016Ms32S/HG025Ms32S/HG040Ms32S/HG040Ms32S/HG063Ms32S/HG100Ms32S/HG100Ms32HG130Ms32HG160Ms32HG160Ms32HG250Ms32HG320Ms63HG250Ms63HG320Ms63HG400Ms63HG500Ms63HG500Ms63HG630
Thermalcurrent
(A)
------------------------
Thermalcurrent
(A)
------------------------
Series
LS4KLS4KLS4KLS4KLS4KLS4KLS4KLS4KLS4KLS4KLS4KLS4KLS4KLS5KLS7KLS7KLS11KLS11KLS11KLS15KLS18KLS22KLS22KLS30K
Series
LS4KLS4KLS4KLS4KLS4KLS4KLS4KLS4KLS5KLS5KLS7KLS11KLS11KLS11KLS11KLS11KLS11KLS15KLS15KLS15KLS18KLS22KLS22KLS30K
Smallestwire Cu(PVC)(2)
380/415V(mm2)
11111111111
1.51.52.52.52.5464610101016
Smallestwire Cu(PVC)(2)
380/415V(mm2)
11111111111
1.51.51.52.52.546466101016
MOTOR(1)
MOTOR(1)
MANUAL MOTOR STARTER
MANUAL MOTOR STARTER
OVERLOAD RELAY
OVERLOAD RELAY
CONTACTOR
CONTACTOR
Coordination Type 1 65kA at 380/400V and 415V
Coordination Type 2 65kA at 380/400V and 415V
(1) Currents are relevant to four pole motors not having special characteristics of torque. Inrush currents: ≤ 8 time rated current for ≤ 1s.(2) The minimum cycle cross-sections are referred to an ambient temperature of 30°C max. in free air and are selected to withstand the maximum let-through energy and the
motor rated current. Besides the user has to consider the drop voltage, the type of laying and ambient temperature.
I