+ All Categories
Home > Documents > PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX...

PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX...

Date post: 28-Mar-2021
Category:
Upload: others
View: 2 times
Download: 0 times
Share this document with a friend
23
POR-FESER EMILIA ROMAGNA 2014-2020 - ASSE 6 CITTA’ ATTRATTIVE E PARTECIPATE IN ATTUAZIONE DELL’AGENDA URBANA PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX TEATRO VERDI Mo.Ve.rdi - Riding, Development, Inspiration 18. OPERE STRUTTURALI - ABACO DEI DETTAGLI COSTRUTTIVI RESPONSABILE DI PROGETTO Arch. Elisa Uccellatori GRUPPO DI PROGETTO Arch. Massimo Davi Arch. Federica Poggi Arch. Sergio Fortini PROGETTAZIONE STRUTTURALE Ing. Denis Zanetti PROGETTAZIONE IMPIANTISTICA Ing. Paolo Magri RESPONSABILE UNICO DI PROGETTO Arch. Natascia Frasson Dirigente del Servizio Beni Monumentali DIRIGENTE SETTORE OOPP Ing. Luca Capozzi
Transcript
Page 1: PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX …servizi.comune.fe.it/8071/attach/benimonumentali/docs/05... · 2016. 11. 4. · - uni en 1992-1-1:2005 - uni en 1993-1-1:2005

POR-FESER EMILIA ROMAGNA 2014-2020 - ASSE 6CITTA’ ATTRATTIVE E PARTECIPATE IN ATTUAZIONE DELL’AGENDA URBANA

PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX TEATRO VERDIMo.Ve.rdi - Riding, Development, Inspiration

18. OPERE STRUTTURALI - ABACO DEI DETTAGLI COSTRUTTIVI

RESPONSABILE DI PROGETTO

Arch. Elisa Uccellatori

GRUPPO DI PROGETTO

Arch. Massimo DaviArch. Federica PoggiArch. Sergio Fortini

PROGETTAZIONE STRUTTURALE

Ing. Denis Zanetti

PROGETTAZIONE IMPIANTISTICA

Ing. Paolo Magri

RESPONSABILE UNICO DI PROGETTO

Arch. Natascia FrassonDirigente del Servizio Beni Monumentali

DIRIGENTE SETTORE OOPP

Ing. Luca Capozzi

Page 2: PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX …servizi.comune.fe.it/8071/attach/benimonumentali/docs/05... · 2016. 11. 4. · - uni en 1992-1-1:2005 - uni en 1993-1-1:2005

BULLONI non a serraggio controllato SB (EN15048-1): VITE CL.8.8 - DADO CL.10 - ROND. A2FORI NELL'ACCIAIO: DIAMETRO BULLONE + 1 mm (PER BULLONE ≤ 20 mm) + 1,5 mm (PER BULLONE > 20 mm)

fykNORMATIVA DI CALCOLO ADOTTATA

NORMATIVA DI RIFERIMENTO : - DM 14.01.2008 " APPROVAZIONE DELLE NUOVE NORME TECNICHE PER LE COSTRUZIONI- CIRCOLARE ESPLICATIVA N° 617 DEL 02.02.2009 AL DM 14.01.2008

ALTRE NORME E DOCUMENTI TECNICI INTEGRATIVI : - UNI EN 1998-4:2006

- UNI EN 1992-1-1:2005- UNI EN 1993-1-1:2005- CNR 2006/2007: ISTRUZIONI PER LA PROGETTAZIONE, L'ESECUZIONE ED

IL CONTROLLO DELLE STRUTTURE IN LEGNO- PROCESSI DI SALDATURA SECONDO EN ISO 4063- ACCETTABILITÀ SALDATURE SECONDO EN ISO 5817- TOLLERANZE DIMENSIONALI SECONDO UNI EN 1090

Ts (Nm)

14161820

242730

22

M.18 ø19.0

M.22 ø23.5

BULLONESIMBOLO FORO

ø25.5

ø21.0

ø17.0ø15.0ø13.0

M.14M.16

M.12

M.20

M.24

ø28.5M.27

M.30 ø31.5

SIMBOLO DI ORIENTAMENTO

COMPOSIZIONE BULLONE

n°1 VITE

CL.1

0.9

CL.6

.8n°1 ROND.n°1 DADO

ISO4014 (6.8)

ISO7089 (A2)ISO4032 (8)

n°1 VITE

n°2 ROND.n°1 DADO

ISO4014 (8.8)

ISO7089 (A2)ISO4032 (10)

n°1 VITE

n°2 ROND.n°1 DADO

ISO4014(10.9)

ISO7089 (A4)ISO4032 (12)

CL.8

.8M

TABELLE SERRAGGIO BULLONI

128.8 10.990 113144 180225 281309 387439 549597 747759 9491110 13881508 1885

X

ø11.0M.10

PRESCRIZIONI SUI MATERIALI AD USO STRUTTURALE

- ACCIAIO PER PROFILI LAMINATI A CALDO E PIASTRE: tipo S275 JR CONFORME D.M. 14.01.2008 E UNI EN 10025-2

t ≤ 40 mm. fyk 275 N/mmq.ftk 430 N/mmq.

40 mm. ≤ t < 80 mm. fyk 255 N/mmq.ftk 410 N/mmq.

IN ZONA SISMICA SOVRARESISTENZA rd (= fym ) ≤ 1.20

BULLONI non a serraggio controllato SB (EN15048-1): VITE CL.8.8 - DADO CL.10 - ROND. A2

- CALCESTRUZZO : CLASSE 25/30 - Rck ≥ 30 N/mmqXC1Slump S4Diametro inerti < 30 mm

- ACCIAIO PER CEMENTO ARMATO B450C (EX FeB44K) :TENSIONE CARATTERISTICA DI SNERVAMENTO ≥ fy nom. 450 N/mm.TENSIONE CARATTERISTICA DI ROTTURA ≥ ft nom. 540 N/mm.1.15 ≤ (ft/fy) k ≤ 1.35ALLUNGAMENTO (Agt) k ≥ 7.5 %P

- LEGNO LAMELLARE: classe GL24

- MURATURA IN BLOCCHI: MURATURA IN BLOCCHI DI LATERIZIO ALVEOLATO PORTANTE IN ZONA SISMICAPERCENTUALE DI FORATURA <45%CARTELLE DI LATERIZIO INTERNE DISPOSTE PARALLELAMENTE AL PIANO DEL MURORESISTENZA CARATTERISTICA Fbk≥ 5MPaRESISTENZA CARATTERISTICA A ROTTURA IN DIREZIONE PERPENDICOLARE A QUELLA PORTANTE Fbk≥ 1.5MPa

- ANCORANTE CHIMICO: PER INGHISAGGI DI BARRE SI PRESCRIVE UTILIZZO DI ANCORANTE CHIMICO TIPO HILT HY200 SISMICO

- TRATTAMENTI PROTETTIVI: DA PREVEDERE ALMENO 2 MANI DI ANTIRUGGINE

- MALTA DA INGHISAGGIO: MALTA CEMENTIZIA ESPANSIVA, APPLICABILE MEDIANTE COLAGGIO PER SPESSORI CENTIMETRICI.UNI 8993 E UNI 8994 CIRCA LE CLASSI DI CONSISTENZA PER I TIPI SUPERFLUIDO, FLUIDO E PLASTICO; UNI 8994 E UNI 8996, UNI 8147 PER L’ESPANSIONE SIA IN FASE PLASTICA CHE INDURITA; UNI 8998, CIRCA L’ASSENZA DI BLEEDINGPRINCIPALI CARATTERISTICHE PRESTAZIONALID ELLA MALTA:

Bleeding, UNI 8998 - Assente Caratteristiche espansive: in fase plastica, UNI 8996 > 0.3 %

contrastata UNI 8147 a 24 ore > 0.03 % Adesione al calcestruzzo, UNI EN 12615 (per taglio) > 6 MPa Resistenza allo sfilamento delle barre d’acciaio, RILEM-CEB-FIP RC6-78 > 30 MPa

NOTE GENERALI:

- TUTTE LE MISURE DOVRANNO ESSERE VERIFICATE DALL'IMPRESA CHE PROVVEDERA' ALTRESI' ALLA REDAZIONE DEGLI ELABORATI D'OFFICINA- I DETTAGLI DEI PACCHETTI E DELLE SOLUZIONI NON STRUTTURALI SONO DA DESUMERE DAGLI ELABORATI ARCHITETTONICI- SI RACCOMANDA DI VERIFICARE CON GLI ELABORATI ARCHITETTONICI LE QUOTE DEGLI IMPALCATI A FINITURE ULTIMATE- TUTTI I MATERIALI PER USO STRUTTURALE DEVONO ESSERE IDENTIFICATI E QUALIFICATI SOTTO LA RESPONSABILITA' DEL PRODUTTORE ED ACCETTATI DAL D.L. IN CONFORMITA' A QUANTO PRESCRITTO AL CAPITOLO 11 DEL D.M. 14.01.2008

SE01 - NOTE GENERALIE PRESCRIZIONI MATERIALI

NOTA:

- PER I PASSAGGI IMPIANTISTICI ATTRAVERSO I SOLAI SI PRESCRIVE DI FORARE IL SOLAIO IN CORRISPONDENZA DELL'ALLEGGERIMENTO IN LATERIZIO O POLISTIROLO CON SUPERVISIONE DELLA D.L. STRUTTURALE

- PER I PASSAGGI IMPIANTISTICI ATTRAVERSO LE PARETI PORTANTI IN MURATURA SI RIMANDA A PARTICOLARE IN TAV. SE03.

Classi di importanza

Categorie di servizio

Categoria diproduzione

PC1

PC2

EXC1 EXC2 EXC2 EXC3 EXC3 EXC3

EXC2 EXC2 EXC2 EXC3 EXC3 EXC4

CC1 CC2 CC3

SC1 SC2 SC1 SC2 SC1 SC2

* SE LA CLASSE DI ESECUZIONE NON è SPECIFICATA APPLICARE LA EXC2

CLASSE DI ESECUZIONE *

PARTICOLARI PRESCRIZIONI PER ACCIAIO PER PROFILI LAMINATI A COLADO E PIASTRE

s1 z1

s1 < s2a1= s1z1=1.4xs1

a2=0.4x s1z2=0.6x s1

Cordone singolo

s2

z2

a

z2

a2

a1

s1 z

Cordone doppio

s2

aa

a

s1 < s2a=0.7xs1z=s1

z1 z

• SALDATURE DA EFFETTUARSI IN OFFICINA, CON CONTROLLO DELLE INTEGRITÁ DELLE STESSE E CERTIFICAZIONE DI CORRETTA ESECUZIONE A REGOLA D'ARTE SECONDO LE PRESCRIZIONI DI NORMATIVA, PREVIA PREPARAZIONE DEI LEMBI

• SALDATURE DA EFFETTUARSI SECONDO PROCEDURE QUALIFICATE UTILIZZANDO LE SPECIFICHE PROCEDURE DI SALDATURA (WPS)

• CRITERI DI ACCETTAZIONE MINIMI (secondo EN ISO 5817): EXC1 livello di qualità DEXC2 livello di qualità CEXC3 livello di qualità BEXC4 livello di qualità B+

• LO SPESSORE DI SALDATURA DEVE ESSERE MAGGIORE O UGUALE AL MINIMO SPESSORE DEI COMPONENTI SALDATI DOVE NON DIFFERENTEMENTE INDICATO

SALDATURE

REQUISITI DI ACCETTAZIONE DEI MATERIALI METALLICI PER PROFILI LAMINATI

- TUTTI I PRODOTTI DI CARPENTERIA METALLICA COPERTI DALLA EN 1090-1, DEVONO POSSEDERE MARCATURA CE E DEVONO ESSERE ACCOMPAGNATI DALLA RELATIVA DICHIARAZIONE DI PRESTAZIONE (DoP)

- LA DICHIARAZIONE DI PRESTAZIONE DEVE ESSERE ACCOMPAGNATA DAL CERTIFICATO DI CONTROLLO DELLA PRODUZIONE IN FABBRICA (FCP)

- L'IMPRESA DEVE FORNIRE: - LE SPECIFICHE DEL PROCEDIMENTO DI SALDATURA DEL COSTRUTTURE (WPS) SECONDO LA UNI EN ISO 15609-1

- IL CERTIFICATO DI APPROVAZIONE DELLE PROCEDURE DI SALDATURA (WPQR)SECONDO LA UNI EN ISO 15614-1

- I PATENTINI DI QUALIFICA DEI SALDATORI SECONDO LA UNI EN ISO 9606-1

PR

OG

ET

TO E

SE

CU

TIV

O D

I LA

BO

RA

TOR

IO A

PE

RTO

NE

LL’E

X-TE

ATR

O V

ER

DI

Mo

Ve.r

di-

Rid

ing

, Dev

elo

pm

ent,

Insp

irat

ion

ELA

BO

RA

TO G

RA

FIC

O:

DA

TA:

TAV

OLA

:S

CA

LA:

+3

+2

+1

0-1-1

0+

1+

2+

3

ELA

BO

RAT

O G

RA

FIC

O :

NO

TE G

EN

ER

ALI

E P

RE

SC

RIZ

ION

I MAT

ER

IALI

DAT

A :

SE

TTE

MB

RE

201

6TA

VOLA

: S

E01

SC

ALA

:

Page 3: PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX …servizi.comune.fe.it/8071/attach/benimonumentali/docs/05... · 2016. 11. 4. · - uni en 1992-1-1:2005 - uni en 1993-1-1:2005

3 IPE

270

3 IPE270

2200

APER

TURA

NET

TA

1000APERTURA NETTA

1000

300

BARRE FILETTATEM14/400 INGHISATE NELLA

MURATURA CON RESINA

BULLONI DI COLLEGAMENTOM14/400

CORDOLO IN C.A. 505x3004 16 CON STAFFE 8/10

QUOTA AL GREZZO PLATEA

BULLONI DI COLLEGAMENTOM14/400

BARRE FILETTATEM14/200 INGHISATE SFALSATE NELLAMURATURA CON RESINA

270 300270300

2470

2140

2140

CORDOLO IN C.A. 505x300 3 IPE270

270 1000 270

2 IPE220

3 IPE

270

BARRE FILETTATEM14/400 INGHISATE NELLA

MURATURA CON RESINA

BULLONI DI COLLEGAMENTOM14/400

2 IPE

200

2 IPE

200

2250

APER

TURA

NET

TA

2100APERTURA NETTA

CORDOLO IN C.A. 300x3004 16 CON STAFFE 8/10 300 200 2100 200 300

270

2470

220

300

QUOTA AL GREZZO PLATEA

QUOTA AL GREZZO INGRESSO

HEA 140ESISTENTE

2 IPE

200

2 IPE220

300

300

3100

3100

BULLONI DI COLLEGAMENTOM14/400

BARRE FILETTATEM14/200 INGHISATE SFALSATE NELLAMURATURA CON RESINA

APERTURA TIPO 1PORTALE METALLICO

VISTASCALA 1:20

SEZIONE 1-1SCALA 1:20

APERTURA TIPO 2PORTALE METALLICO

VISTASCALA 1:20

SEZIONE 2-2SCALA 1:20

A2-20mm SCAL PLOT 1=20

A2-20mm

PART.2

PART.1

M14/400

PART.4

PART.3

10

CORDONI DI SALDATURAL=100 PASSO 400

300 QUOTA AL GREZZO INGRESSO

505

3 IPE270

3 IPE

270

CORDONI DI SALDATURAL=100 PASSO 400

10

SEZIONE 3-3SCALA 1:20

NOTA :PER I PARTICOLARI RELATIVI ALLACONNESSIONE COLONNA - TRAVEVEDERE TAVOLA SE03

3 IPE

270

3 IPE270

2200

APER

TURA

NET

TA

1300APERTURA NETTA

1300

300

BARRE FILETTATEM14/400 INGHISATE NELLA

MURATURA CON RESINA

BULLONI DI COLLEGAMENTOM14/400

CORDOLO IN C.A. 505x3004 16 CON STAFFE 8/10

QUOTA AL GREZZO

BULLONI DI COLLEGAMENTOM14/400

BARRE FILETTATEM14/200 INGHISATE SFALSATE NELLAMURATURA CON RESINA

270 300270300

2470

2440

2140

3 IPE

270

270

APERTURA TIPO 3PORTALE METALLICO

VISTASCALA 1:20

PART.2

PART.1

SE02 - CERCHIATURE METALLICHEVISTE E SEZIONI

PUNTELLARESTRUTTUREESISTENTI

PUNTELLARESTRUTTUREESISTENTI

INSERIMENTO DI BIETTE METALLICHE INSERIMENTO DI BIETTE METALLICHE

INSERIMENTO DI BIETTE METALLICHE

PROCEDURA TIPICA PER INSERIMENTO PORTALI :

1 - DEMOLIZIONE IN BRECCIA DELLA MURATURA PER INSERIMENTO ARCHITRAVATURA ORIZZONTALE INTERNA.2 - DEMOLIZIONE IN BRECCIA MURATURE VERTICALI ED INSERIMENTO PIEDRITTI.3 - MESSA IN SPINTA DEI PIEDRITTI.4 - INSERIMENTO BIETTE DI COAZIONE IN ACCIAIO A SP. VARIABILE CHIUSE A FORZA.5 - INGHISAGGI DEI PERNI VERTICALI.6 - PROCEDERE DA 1 A 5 SUL LATO OPPOSTO.7 - INGHISAGGIO DI BASE.

505

PR

OG

ET

TO E

SE

CU

TIV

O D

I LA

BO

RA

TOR

IO A

PE

RTO

NE

LL’E

X-TE

ATR

O V

ER

DI

Mo

Ve.r

di-

Rid

ing

, Dev

elo

pm

ent,

Insp

irat

ion

ELA

BO

RA

TO G

RA

FIC

O:

DA

TA:

TAV

OLA

:S

CA

LA:

+3

+2

+1

0-1-1

0+

1+

2+

3

ELA

BO

RAT

O G

RA

FIC

O :

CE

RH

IATU

RE

ME

TALL

ICH

E V

ISTE

E S

EZI

ON

ITA

VOLA

: S

E02

SC

ALA

: 1:

20D

ATA

: S

ETT

EM

BR

E 2

016

Page 4: PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX …servizi.comune.fe.it/8071/attach/benimonumentali/docs/05... · 2016. 11. 4. · - uni en 1992-1-1:2005 - uni en 1993-1-1:2005

505

300

SEZIONE A-ASCALA 1:10

4 16

L=1550

240

440

STAFFE 8/10300

300

SEZIONE B-BSCALA 1:10

4 16

L=1150

240

240

STAFFE 8/10

A2-20mm SCAL PLOT 1=20A2-20mm

270

90 87.5 87.5 90 50

405

5085

50

35 100

505

185

135

185

5085

5045

4545

PARTICOLARE 1SCALA 1:10

IPE270 PIASTRA 10

10 IN OPERA

M16 CON PIATTO 50X50X5PER TERMINALE A MARTELLO

135

135

IPE270

IPE270

9014011550

395

135

IPE270

PARTICOLARE 2SCALA 1:10

PIASTRA 10

10 IN OPERAM16

IPE270

200

90 87.5 107.5 50

335

5050

5050

300

35 100

150

150

100

PARTICOLARE 3SCALA 1:10

M16 CON PIATTO 50X50X5PER TERMINALE A MARTELLO

PIASTRA 10

10 IN OPERA

35100

110

110

200

IPE200

IPE200

3369

6669

6669

33

8510010050

5511

055

M16

SE03 - CERCHIATURE METALLICHEPARTICOLARI

PARTICOLARE 4SCALA 1:10

PARTICOLARE CERCHIATURA MURATURE ESISTENTI PER PASSAGGIO IMPIANTISCALA 1:10

PARETE ESISTENTEIN MURATURA A 2 TESTE

CERCHIATURA UPN120

BARRE 14/150 mm. INGHISATENELLA MURATURA ESISTENTE

3010

IPE270

35 270 100

SEZIONE C-CSCALA 1:10

3010

IPE200

35

SEZIONE D-DSCALA 1:10

IPE200

IPE200

200 100

509087.587.590 50107.587.590

900

300

150

150

PARETE ESISTENTEIN MURATURA A 2 TESTE

UPN120

M16 M16

PIASTRA 10 PIASTRA 10

PR

OG

ET

TO E

SE

CU

TIV

O D

I LA

BO

RA

TOR

IO A

PE

RTO

NE

LL’E

X-TE

ATR

O V

ER

DI

Mo

Ve.r

di-

Rid

ing

, Dev

elo

pm

ent,

Insp

irat

ion

ELA

BO

RA

TO G

RA

FIC

O:

DA

TA:

TAV

OLA

:S

CA

LA:

+3

+2

+1

0-1-1

0+

1+

2+

3

ELA

BO

RAT

O G

RA

FIC

O :

CE

RC

HIA

TUR

E M

ETA

LLIC

HE

PA

RTI

CO

LAR

ITA

VOLA

: S

E03

SC

ALA

: 1:

10D

ATA

: S

ETT

EM

BR

E 2

016

Page 5: PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX …servizi.comune.fe.it/8071/attach/benimonumentali/docs/05... · 2016. 11. 4. · - uni en 1992-1-1:2005 - uni en 1993-1-1:2005

PROFILO ANGOLARE 100x100INGHISATO CON M14/200

GETTO INTEGRATIVO IN CLS

RETE ELS 8/200x200

LAMIERA GRECATATIPO HI BOND A55/P770

INGHISAGGI 10/400

TRAVE IN SPESSORE ESISTENTE

SOLAIO IN LATEROCEMENTO 200+40mm

HEA

140

ESIS

TENT

E

PART.A

4555

240

RETE 6/100x100INGHISAGGI 10/400

GETTO COLLABORANTE

LAMIERA GRECATA

ANGOLARE 100x100x10

INGHISAGGIO PROFILO M14/200

PROFILO ANGOLARE DI CHIUSURA E SOSTEGNO GRECATA 100x100x5

CHIUSURA CON GRECATA

TRAVE IN SPESSORE ESISTENTE

CHIUSURA CAVEDIO 1PRIMO SOLAIO

PART.ASCALA 1:10

PIANTASCALA 1:20

MODIFICA DIMENSIONE VANO ASCENSORE IN MURATURA

PIANTASCALA 1:20

A2-20mm SCAL PLOT 1=20A2-20mm

SE04 - CHIUSURA CAVEDIE FORI SOLAI

2331

1847

200

NUOVA PARETE INBLOCCHI DI LATERIZIOsp.20 cm.

BARRE 14 INGHISATENELLA MURATURA ESISTENTE(n.3/mq.)

NOTA :SI RACCOMANDA DI VERIFICARELE DIMENSIONE INTERNE DELVANO CON IL FORNITORE DEL MONTAPERSONE

CHIUSURA CAVEDIO IN COPERTURA

1 10/40 L.=10+20 cm.SALDATO AL PROFILO

200

100

4555

SEZIONE 1-1SCALA 1:10

200

HEA140

EVENTUALE APPOGGIO

1 10/40 L.=10-20 cm.SALDATO AL PROFILO

PR

OG

ET

TO E

SE

CU

TIV

O D

I LA

BO

RA

TOR

IO A

PE

RTO

NE

LL’E

X-TE

ATR

O V

ER

DI

Mo

Ve.r

di-

Rid

ing

, Dev

elo

pm

ent,

Insp

irat

ion

ELA

BO

RA

TO G

RA

FIC

O:

DA

TA:

TAV

OLA

:S

CA

LA:

+3

+2

+1

0-1-1

0+

1+

2+

3

B

C

C

C

A

A B

C

ELA

BO

RAT

O G

RA

FIC

O :

CH

IUS

UR

A C

AVE

DI E

FO

RI S

OLA

ITA

VOLA

: S

E04

SC

ALA

: 1:

10 -

1:20

DAT

A :

SE

TTE

MB

RE

201

6

Page 6: PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX …servizi.comune.fe.it/8071/attach/benimonumentali/docs/05... · 2016. 11. 4. · - uni en 1992-1-1:2005 - uni en 1993-1-1:2005

A2-20mm SCAL PLOT 1=20

A2-20mm

SE05 - CHIUSURA CAVEDIE FORI SOLAI

PIANTASCALA 1:50

CHIUSURA VANO C.T.

HEA

200

ESIS

TENT

E

HEA

200

ESIS

TENT

EHEA 140 ESISTENTE

HEA 140

GETTO IN CLSESISTENTE

LAMIERA GRECATAESISTENTE

HEA 140

2800

1900

CONNETTORE A PIOLO12/200

BOTOLA1200

900

NUOVA LAMIERAGRECATA (*)

NUOVO GETTO IN CLSCON RETE ELETTROSALDATA (*)

SEZIONE 1-1SCALA 1:10

HEA 140

HEA200ESISTENTE

5040

4357

55

PIATTO sp.10 mm.SALDATO IN OPERA

PIANO PRIMOCHIUSURA n.3 APERTURE SOLAIO

quote in mm. quote in mm.

1

2 32000

1800

1650

100010006001000

1650

CHIUSURA APERTURE SOLAIO (TIPICO)SCALA 1:20

NUOVO GETTODI COMPLETAMENTO

INGHISAGGI 10/400L=250 mm.

SOLAIO PREDALLESh=4+12+5 ESISTENTE

INGHISAGGI 10/400L=250 mm.

NUOVO GETTODI COMPLETAMENTOCON RETE ELETTROSALDATA

6/20X20

NOTA(*) ALTEZZA LAMIERA GRECATA E GETTO DA VERIFICARE CON ESISTENTE

DEMOLIZIONE DI10 cm. DI CLS PERAPPOGGIO NUOVAGRECATA

120

480

1 20

200

2 00

200 20010

0

150

PANNELLI DIALLEGGERIMENTOIN POLISTIROLO H.=12 cm.

SEZIONE 2-2SCALA 1:10

4012

040

200

PANNELLI DIALLEGGERIMENTO

IN POLISTIROLOH.=12 cm.

120

RETE ELETTROSALDATA6/20X20

PIOLI NELSON

PIOLI NELSON

PR

OG

ET

TO E

SE

CU

TIV

O D

I LA

BO

RA

TOR

IO A

PE

RTO

NE

LL’E

X-TE

ATR

O V

ER

DI

Mo

Ve.r

di-

Rid

ing

, Dev

elo

pm

ent,

Insp

irat

ion

ELA

BO

RA

TO G

RA

FIC

O:

DA

TA:

TAV

OLA

:S

CA

LA:

+3

+2

+1

0-1-1

0+

1+

2+

3

TAVO

LA :

SE

05 S

CA

LA :

1:20

- 1:

10E

LAB

OR

ATO

GR

AFI

CO

: C

HIU

SU

RA

CAV

ED

I E F

OR

I SO

LAI

DAT

A :

SE

TTE

MB

RE

201

6

B

A

B

A

Page 7: PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX …servizi.comune.fe.it/8071/attach/benimonumentali/docs/05... · 2016. 11. 4. · - uni en 1992-1-1:2005 - uni en 1993-1-1:2005

A2-20mm SCAL PLOT 1=20

A2-20mm

NOTA :SI PRESCRIVE LAMIERA GRECATATIPO HI-BOND A55 P770 DISPESSORE 0.7 mm.

1Ø10/20 SUP.1Ø10/20 INF.

1200

2000

SOLAIO PREDALLESH.=16+4 cm.

3+3 16 INF. + SUP.LUNGO IL PERIMETRO

PARETE IN MURATURA A TRE TESTESU VIA CAMALEONTE

FORO ESISTENTESU SOLAIO

PIANTA STATO DI FATTOSCALA 1:20

1Ø10/20 SUP.1Ø10/20 INF.

1200

2000

3+3 16 INF. + SUP.LUNGO IL PERIMETRO

PARETE IN MURATURA A TRE TESTESU VIA CAMALEONTE

PIANTA PROGETTOSCALA 1:20

650

650

LAMIERA GRECATA H55TIPO HI-BOND A55/P770

CHIUSINO DI ISPEZIONEVASCA ANTINCENDIO

M12/20

PRESSOPIEGATO 125x80x10

PROFILO DI APPOGGIOL80x80x10

FINITURA QUOTA FINITO +0.21 m.(+10 cm. DA STATO DI FATTO)

GETTO C.L.S.COLLABORANTE6 cm.

RETE 8 MAGLIA 20x20 cm.

M12/25

SEZIONE A-ASCALA 1:10

200

6055

115

1 10/40 RETE ELETTROSALDATA 8 MAGLIA 20x20 cm.GETTO IN C.L.S. COLLABORANTE 6 cm.

LAMIERA GRECATA H55TIPO HI-BOND A55/P770

M12/25ANGOLARE L80x80x10

SEZIONE B-BSCALA 1:10

200

1 10/40RETE ELETTROSALDATA 8 MAGLIA 20x20 cm.GETTO IN C.L.S. COLLABORANTE 6 cm.

PRESSOPIEGATO 125x80x10 M12/25ANGOLARE L80x80x10

LAMIERA GRECATA H55TIPO HI-BOND A55/P770

ANGOLARE L60x60x6APPOGGIO PIASTRA DI

CHIUSURA CHIUSINO

M12/20

200

6055

115

RETE ELETTROSALDATA 8 MAGLIA 20x20 cm.GETTO IN C.L.S. COLLABORANTE 6 cm.

LAMIERA GRECATA H55TIPO HI-BOND A55/P770

100

SEZIONE C-CPARTICOLARE FINITURA CHIUSINOSCALA 1:10

650

+0.21 P. FINITO

SE06 - CHIUSURA VASCA ANTINCENDIO

CHIUSURA VASCA ANTINCENDIO

SOLAIO PREDALLESH.=16+4 cm.

BOTOLA DA DEFINIRE CON LA D.L.FINITURA SUPERFICIALE CONFORMEA PAVIMENTO

PR

OG

ET

TO E

SE

CU

TIV

O D

I LA

BO

RA

TOR

IO A

PE

RTO

NE

LL’E

X-TE

ATR

O V

ER

DI

Mo

Ve.r

di-

Rid

ing

, Dev

elo

pm

ent,

Insp

irat

ion

ELA

BO

RA

TO G

RA

FIC

O:

DA

TA:

TAV

OLA

:S

CA

LA:

+3

+2

+1

0-1-1

0+

1+

2+

3

TAVO

LA :

SE

06 S

CA

LA :

1:20

- 1:

10E

LAB

OR

ATO

GR

AFI

CO

: C

HIU

SU

RA

VA

SC

A A

NTI

NC

EN

DIO

DAT

A :

SE

TTE

MB

RE

201

6

Page 8: PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX …servizi.comune.fe.it/8071/attach/benimonumentali/docs/05... · 2016. 11. 4. · - uni en 1992-1-1:2005 - uni en 1993-1-1:2005

INTERVENTO SULLA COPERTURA DELLA PLATEA

PART.A

PIANTA COPERTURASCALA 1:100

A2-20mm SCAL PLOT 1=20A2-20mm

PARTICOLARE ASCALA 1:5

80

2 L80x80x8

2M16

PIATTO 72x72x8SALDATO IN OPERAAD ANGOLARE

SEZIONE 2-2SCALA 1:5

8080 8 80

2M16

SE07 - NUOVI ROMPITRATTAIN COPERTURA

NOTA• STRUTTURA RETICOLARE METALLICA ESISTENTE• SI PRESCRIVE DI PROTEGGERE CON ZINCATURA A FREDDO,

DOPO L'INSTALLAZIONE DEI NUOVI PROFILI, I PUNTI DI CONTATTO CON LA STRUTTURA ESISTENTE

• PER QUANTO RIGUARDA I PARTICOLARI RELATIVI AI NUOVI PANNELLI DI COPERTURA SI RIMANDA AGLI ELABORATI ARCHITETTONICI DI PROGETTO

DOPPIO ANGOLAREESISTENTE

DOPPIO ANGOLARE ESISTENTE

DOPPIO ANGOLAREESISTENTE

SALDATURA IN OPERA

SEZIONE 1-1SCALA 1:5

SALDATURA IN OPERA

PR

OG

ET

TO E

SE

CU

TIV

O D

I LA

BO

RA

TOR

IO A

PE

RTO

NE

LL’E

X-TE

ATR

O V

ER

DI

Mo

Ve.r

di-

Rid

ing

, Dev

elo

pm

ent,

Insp

irat

ion

ELA

BO

RA

TO G

RA

FIC

O:

DA

TA:

TAV

OLA

:S

CA

LA:

+3

+2

+1

0-1-1

0+

1+

2+

3

TAVO

LA :

SE

07 S

CA

LA :

1:10

0 - 1

:5E

LAB

OR

ATO

GR

AFI

CO

: N

UO

VI R

OM

PIT

RAT

TA IN

CO

PE

RTU

RA

DAT

A :

SE

TTE

MB

RE

201

6

Page 9: PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX …servizi.comune.fe.it/8071/attach/benimonumentali/docs/05... · 2016. 11. 4. · - uni en 1992-1-1:2005 - uni en 1993-1-1:2005

1000

200

500

150

SCALA MARINARA CON PROTEZIONE

NUOVO PARAPETTO PASSERELLA

PROFILI HEA 120

HEA 120

GRIGLIATO 34x38 PIATTO 25x2

CORRENTE 40x20x2

MONTANTE 40x40x4

CORRENTE 40x20x2

PARAPIEDEPIATTO IN ACCIAIO 30/10

40

40

20

40

NUOVA PASSERELLA

STRALCIO SEZIONE TORRE SCENICASCALA 1:50

SEZIONE 3-3SCALA 1:10

305

440

114

1139

A2-20mm SCAL PLOT 1=20A2-20mm

SE08 - PASSERELLA TORRESCENICA

PART.1

25012

5

4085

125

125 125

40858540

PART. 1SCALA 1:10

PART.2

MONTANTE 40x40x4

HEA 120

PART. 2SCALA 1:5

PIATTOsp.10 mm.

120

4040

40

70

SALDATURE 10

800

n.3+3 M20

n.3+3 M20

PR

OG

ET

TO E

SE

CU

TIV

O D

I LA

BO

RA

TOR

IO A

PE

RTO

NE

LL’E

X-TE

ATR

O V

ER

DI

Mo

Ve.r

di-

Rid

ing

, Dev

elo

pm

ent,

Insp

irat

ion

ELA

BO

RA

TO G

RA

FIC

O:

DA

TA:

TAV

OLA

:S

CA

LA:

+3

+2

+1

0-1-1

0+

1+

2+

3

TAVO

LA :

SE

08 S

CA

LA :

1:50

- 1:

10E

LAB

OR

ATO

GR

AFI

CO

: PA

SS

ER

ELL

A T

OR

RE

SC

EN

ICA

DAT

A :

SE

TTE

MB

RE

201

6

Page 10: PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX …servizi.comune.fe.it/8071/attach/benimonumentali/docs/05... · 2016. 11. 4. · - uni en 1992-1-1:2005 - uni en 1993-1-1:2005

2500

100

2400

SBARCO SCALA

BARACCATURA DI COPERTURA PIANTASCALA 1:20

1350

1460

A2-20mm SCAL PLOT 1=20A2-20mm

NOTA :PRIMA DI PRODURRE I PROFILI E' NECESSARIO VERIFICAREIN SITO LE DIMENSIONI AVENDO CURA DI PULIRE LA SUPERFICIE DI BASE DI APPOGGIO DEI MONTANTI

*

*

PARETE IN BLOCCOCASSERO

PART.2

PARETE IN MURATURA

500

CORDOLO IN C.A.

PARETE IN BLOCCO CASSERO

800

PART.3 PART.1

MONTANTE TUBOLARE60x60x2 INTERASSE 90 cm.

PANNELLO IN POLICARBONATODI CHIUSURA SP.=40 mm.

SCOSSALINA DI TESTATA

CORRENTE TUBOLAREDI CHIUSURA 60x60x2

TUBOLARE 60x60x2INTERASSE MAX 90 cm.

PANNELLO DI COPERTURAH.=100 mm.

ANGOLARE L60x60x6

PROSPETTOSCALA 1:20

PANNELLO IN POLICARBONATODI CHIUSURA SP.=40 mm.

SCOSSALINA DI TESTATA

CORRENTE TUBOLARE DICHIUSURA 60x60x2

MONTANTE TUBOLARE60x60x2INTERASSE 90 cm.

900 900

PARTICOLARE 1SCALA 1:5

60

60

TUBOLARE 60x60x2

N° 1 BULLONE M16

MONCONE 50x50x3L.=50 mm. SALDATOA TUBOLARE CORRENTE

MONCONE 50x50x3L.=50 mm. SALDATOA TUBOLARE CORRENTE

N° 1 BULLONE M16MONTANTE 60x60x2

PARTICOLARE 2SCALA 1:5

6060

120

3060

30

30 120 30

60 60 60

180

TASSELLO M16INGHISATO CON RESINATIPO HILTI HY200

SALDATURE IN OFFICINA5

5

PARTICOLARE 3SCALA 1:5

100

60

CORDONE DI SALDATURA IN OPERA

ANGOLARE 60x60x6

PANNELLO DI CHIUSURA H.=100

IMPERMEABILIZZAZIONEDA VERIFICARE CON LA D.L.

TASSELLO M14/40 CONANCORAGGIO CHIMICOTIPO HILTI HY200

2%

SE09 - BARACCATURA IN COPERTURA

4a 1a2a3a5a6a7a8a9a

PR

OG

ET

TO E

SE

CU

TIV

O D

I LA

BO

RA

TOR

IO A

PE

RTO

NE

LL’E

X-TE

ATR

O V

ER

DI

Mo

Ve.r

di-

Rid

ing

, Dev

elo

pm

ent,

Insp

irat

ion

ELA

BO

RA

TO G

RA

FIC

O:

DA

TA:

TAV

OLA

:S

CA

LA:

+3

+2

+1

0-1-1

0+

1+

2+

3

TAVO

LA :

SE

09 S

CA

LA :

1:20

- 1:

10E

LAB

OR

ATO

GR

AFI

CO

: B

AR

AC

CAT

UR

A IN

CO

PE

RTU

RA

DAT

A :

SE

TTE

MB

RE

201

6

Page 11: PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX …servizi.comune.fe.it/8071/attach/benimonumentali/docs/05... · 2016. 11. 4. · - uni en 1992-1-1:2005 - uni en 1993-1-1:2005

SE10 - INQUADRAMENTO NUOVESTRUTTURE METALLICHE ZONA BLACK BOX

STRUTTURA "A" - SCALA DI EMERGENZATAVOLE SE11 - SE12 - SE13

STRUTTURA "B" - FRONTE BLACK BOXTAVOLE SE14 - SE15 - SE16

INQUADRAMENTO GENERALE

GIUNTO STRUTTURALE

A B C D

12

3

1

1'

E E E

PR

OG

ET

TO E

SE

CU

TIV

O D

I LA

BO

RA

TOR

IO A

PE

RTO

NE

LL’E

X-TE

ATR

O V

ER

DI

Mo

Ve.r

di-

Rid

ing

, Dev

elo

pm

ent,

Insp

irat

ion

ELA

BO

RA

TO G

RA

FIC

O:

DA

TA:

TAV

OLA

:S

CA

LA:

+3

+2

+1

0-1-1

0+

1+

2+

3

TAVO

LA :

SE

10 S

CA

LA :

ELA

BO

RAT

O G

RA

FIC

O :

INQ

UA

DR

AM

EN

TO N

UO

VE S

TRU

TTU

RE

ME

TALL

ICH

ED

ATA

: S

ETT

EM

BR

E 2

016

Page 12: PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX …servizi.comune.fe.it/8071/attach/benimonumentali/docs/05... · 2016. 11. 4. · - uni en 1992-1-1:2005 - uni en 1993-1-1:2005

1

2

3

4

5

6

7

8

9

10

1112

13

14

15

16

17

18

19

20

21

22

2324

HEA2

00

HEA2

00

HEA2

00

HEA1

20

IPE160 IPE160

12345678910111213

14 15 16

PIANTA A q=+0.60 m.Scala 1:25

+0.40

+0.40

+2.26

13 a

lzate

x 1

69.2

= 2

200

mm

.11

alza

te x

169

.2 =

186

1 m

m.

A B C D

A B C D

12

3

AA

HEA200 HEA200

169

1315

SEZIONE A-AScala 1:25

IPE160

B

B

UPN220

UPN220

2690

8011

0080

170

8011

0080

12 pedate x 300 = 3600 mm.

UPN220

UPN220UPN220

UPN220

5020

8120

30+0.13

3577 825 964

IPE160

-1.80 q.p.f.

-1.90

5030

050

50 300 50

400

400

-1.90

-1.80 q.p.f.

1090

-1.90

-1.80 q.p.f.

SALDATURADA REALIZZAREIN OPERA

500

5040

050

400

50 300 50

9540

5

SALDATURADA REALIZZAREIN OPERA

1

PART. PIASTRA DI BASE HEA200/UPN220Scala 1:10

Lmin 3

50

3'

1'

E

1090

Lmin 3

50

5030

050

50 200 50

400

400

-1.90

-1.80 q.p.f.

1090

PART. PIASTRA DI BASE HEA200 (FILO )Scala 1:10

Lmin 3

50

100

1C

PART. PIASTRA DI BASE HEA200 (FILO )Scala 1:10

1A

SE11 - NUOVA SCALA METALLICAVISTE E PARTICOLARI

PIATTIsp.10 mm.

PIATTIsp.10 mm.

340

50

GIUNTOSTRUTTURALE

50

GIUNTOSTRUTTURALE

PER PIASTRE DI BASE COLONNE HEA120 VEDI TAV. SE13

VERIFICAREQUOTA ESIST.

VERIFICAREQUOTA ESIST.

VERIFICAREQUOTA ESIST.

VERIFICAREQUOTA ESIST.

1825

160

PR

OG

ET

TO E

SE

CU

TIV

O D

I LA

BO

RA

TOR

IO A

PE

RTO

NE

LL’E

X-TE

ATR

O V

ER

DI

Mo

Ve.r

di-

Rid

ing

, Dev

elo

pm

ent,

Insp

irat

ion

ELA

BO

RA

TO G

RA

FIC

O:

DA

TA:

TAV

OLA

:S

CA

LA:

+3

+2

+1

0-1-1

0+

1+

2+

3

TAVO

LA :

SE

11 S

CA

LA :

1:25

- 1:

10E

LAB

OR

ATO

NU

OVA

SC

ALA

ME

TALL

ICA

VIS

TE E

PA

RTI

CO

LAR

ID

ATA

: S

ETT

EM

BR

E 2

016

Page 13: PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX …servizi.comune.fe.it/8071/attach/benimonumentali/docs/05... · 2016. 11. 4. · - uni en 1992-1-1:2005 - uni en 1993-1-1:2005

+0.40+0.40

HEA2

00

HEA200

1100 80 170 1100 8080 80

2690

2200

-1.80 q.p.f.-1.80 q.p.f.

1305 1385

SEZIONE B-BScala 1:25

2345678910111213

14 15 16

PIANTA A q=+2.26 m.Scala 1:25

A B C D

1

AA

B

B

17 18 19 20 21 22 23 24

1100

+0.40

2690

8011

0080

170

8011

0080

UPN220

UPN220UPN220

UPN220

IPE160

IPE160

IPE160 IPE160

IPE160

IPE1

60

3577 825 964

C

C

D

D

TONDO 20

1

+2.26+2.26

HEA2

00HEA200

4061

-1.80-1.80

1305 1365

SEZIONE C-CScala 1:25

1100

1100

2670

IPE160

IPE160

1100

SEZIONE D-DScala 1:25

+2.26+2.26

1238

HEA1

20

HEA1

20-1.80-1.80

+0.13+0.13

4161

-1.90-1.90 -1.90-1.90 -1.90-1.90

SE12 - NUOVA SCALA METALLICAVISTE E PARTICOLARI

E

2

3

1

3'

1'

169

1113

340

2690

VERIFICAREQUOTA ESIST.

VERIFICAREQUOTA ESIST.

VERIFICAREQUOTA ESIST.

PART.2

PART.1

PART.1

PR

OG

ET

TO E

SE

CU

TIV

O D

I LA

BO

RA

TOR

IO A

PE

RTO

NE

LL’E

X-TE

ATR

O V

ER

DI

Mo

Ve.r

di-

Rid

ing

, Dev

elo

pm

ent,

Insp

irat

ion

ELA

BO

RA

TO G

RA

FIC

O:

DA

TA:

TAV

OLA

:S

CA

LA:

+3

+2

+1

0-1-1

0+

1+

2+

3

TAVO

LA :

SE

12 S

CA

LA :

1:25

ELA

BO

RAT

O G

RA

FIC

O :

NU

OVA

SC

ALA

ME

TALL

ICA

VIS

TE E

PAT

ICO

LAR

ID

ATA

: S

ETT

EM

BR

E 2

016

Page 14: PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX …servizi.comune.fe.it/8071/attach/benimonumentali/docs/05... · 2016. 11. 4. · - uni en 1992-1-1:2005 - uni en 1993-1-1:2005

390

50 110 70 110 50

200

5010

050

HEA2

00

HEA2

00

39080 20

1020

80

8020

10

10 10 10 10

HEA200

100

PIATTOsp.10 mm.

10PIATTOsp.10 mm.

PIATTOsp.10 mm.

UPN200COSCIALISCALA

L80x8L80x8200

L80x8

UPN220

IPE160

50

6040

90

PART. 1Scala 1:10

-1.90-1.90

-1.80 q.p.f.-1.80 q.p.f.

PART. PIASTRA DI BASE HEA120 (FILO )Scala 1:10

4017

040

40 170 40

250

250

50

HEA2

00

390

50 110 70 110 50

300

5010

015

0

HEA2

00

HEA200

UPN220

300

390

TONDO 20TONDO 20

IPE1

60

1010

220

6080

50

15040 70 40

30

UPN220COSCIALESCALA

PIATTO390x300x10 mm.

100100

100 100

10 10 50 50

6040

6030

IPE160

4

PART. 2Scala 1:10

UPN2

20

HEA200

1

1

4

VISTA 4-4

3 3

VISTA 2-2

VISTA 3-3

1090

Lmin 3

50

PIATTIsp.10 mm.

-1.90-1.90

-1.80 q.p.f.-1.80 q.p.f.

4012

040

40 170 40

250

250

1090

Lmin 3

50

PIATTIsp.10 mm.

50

PART. PIASTRA DI BASE HEA120 (FILO )Scala 1:10

2D

220 190

TONDO 20

SE13 - NUOVA SCALA METALLICAPARTICOLARI

PART. PARAPETTOScala 1:10

TUBO60.3/2.9

TUBO60.3/2.9

TUBO26.9/2

1100

500

UPN220

2565

6525

55 25PIATTOsp.8 mm.

D 3

VERIFICAREQUOTA ESIST.

2 2

VISTA 2-2

VISTA 1-1

2

2

PR

OG

ET

TO E

SE

CU

TIV

O D

I LA

BO

RA

TOR

IO A

PE

RTO

NE

LL’E

X-TE

ATR

O V

ER

DI

Mo

Ve.r

di-

Rid

ing

, Dev

elo

pm

ent,

Insp

irat

ion

ELA

BO

RA

TO G

RA

FIC

O:

DA

TA:

TAV

OLA

:S

CA

LA:

+3

+2

+1

0-1-1

0+

1+

2+

3

TAVO

LA :

SE

13 S

CA

LA :

1:1

0E

LAB

OR

ATO

GR

AFI

CO

: N

UO

VA S

CA

LA P

AR

TIC

OLA

RI

DAT

A :

SE

TTE

MB

RE

201

6

Page 15: PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX …servizi.comune.fe.it/8071/attach/benimonumentali/docs/05... · 2016. 11. 4. · - uni en 1992-1-1:2005 - uni en 1993-1-1:2005

E F GPIANTA PIASTRE DI BASE q=-1,90 m.Scala 1:25

4082 2103

PIANTA PIANO A q=+2,115 m. p.s.f. - PIANO DI SBARCO BLACKBOX (q=+2,26 p.f.)Scala 1:25

1'

2

33'

1156

HEA200

HEA200

HEA120

HEA120

D

1825

HEA200 HEA200

HEA200 HEA200

E F G4082 2103

1'

2

33'

1156

D

1825

IPE200

IPE200

IPE200

IPE2

00

IPE2

00

IPE2

00

PIANTA PIANO A q=+4,24 m. p.s.f.Scala 1:25E F G

4082 2103

1'

3

1825

IPE1

60

IPE1

60

IPE1

60

IPE160

IPE160

IPE160

5030

050

50 300 50

400

400

-1.90

-1.80 q.p.f.

1090

Lmin 3

50

PART. PIASTRA DI BASE HEA200Scala 1:10

PIATTIsp.10 mm.

SE14A - NUOVO VANO ASCENSOREPIANTE E PARTICOLARI

INQUADRAMENTO GENERALE

VERIFICAREQUOTA ESIST.

TRAVETTI IN LEGNO8x12 cm.

INTERASSE max 80 cm.

BLACK BOX

TRAVETTI IN LEGNO 16x24 cm.INTERASSE max 80 cm.

PART.1 - GIUNTO STRUTTURALE CON BLACKBOXScala 1:10

+2,26

+2,115 p.s.f.

CARPLYsp.25 mm.

TRAVETTI INLEGNO 8x12 cm.

IPE200

PIATTO 100x100 sp.5 mm.SALDATO ALLA TRAVE

TRAVETTI INLEGNO 16x24 cm.

i=80 cm.80

GIUNTOSISMICO

SELLA IN PRESSOPIEGATO150x100 sp.6 mm.i=80 cm.

PART.1

161

161

PR

OG

ET

TO E

SE

CU

TIV

O D

I LA

BO

RA

TOR

IO A

PE

RTO

NE

LL’E

X-TE

ATR

O V

ER

DI

Mo

Ve.r

di-

Rid

ing

, Dev

elo

pm

ent,

Insp

irat

ion

ELA

BO

RA

TO G

RA

FIC

O:

DA

TA:

TAV

OLA

:S

CA

LA:

+3

+2

+1

0-1-1

0+

1+

2+

3

TAVO

LA :

SE

14 S

CA

LA :

1:2

5 - 1

:10

ELA

BO

RAT

O G

RA

FIC

O :

NU

OVO

VA

NO

AS

CE

NS

OR

E P

IAN

TE E

PA

RTI

CO

LAR

ID

ATA

: S

ETT

EM

BR

E 2

016

Page 16: PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX …servizi.comune.fe.it/8071/attach/benimonumentali/docs/05... · 2016. 11. 4. · - uni en 1992-1-1:2005 - uni en 1993-1-1:2005

PIANTA PIANO A q=+5,50 m. p.s.f.Scala 1:25E F G

4083 2103

1'

3

1825

IPE1

60

IPE1

60

IPE1

60

IPE160

IPE160

PIANTA PIANO A q=+9,28 m. p.s.f.Scala 1:25E F G

4083 2103

1'

3

1825

IPE1

60

IPE1

60

IPE1

60IPE160

IPE160

5030

050

50 300 50

400

400

-1.90

-1.80 q.p.f.

1090

Lmin 3

50

PART. PIASTRA DI BASE HEA200Scala 1:10

PIATTIsp.10 mm.

SE15A - NUOVO VANO ASCENSOREPIANTE E PARTICOLARI

PIANTA PIANO A q=+6,76 m. p.s.f.Scala 1:25

E F G4083 2103

1'

3

1825

IPE1

60

IPE1

60

IPE1

60

IPE160

IPE160

IPE160

INQUADRAMENTO GENERALE

VERIFICAREQUOTA ESIST.

PR

OG

ET

TO E

SE

CU

TIV

O D

I LA

BO

RA

TOR

IO A

PE

RTO

NE

LL’E

X-TE

ATR

O V

ER

DI

Mo

Ve.r

di-

Rid

ing

, Dev

elo

pm

ent,

Insp

irat

ion

ELA

BO

RA

TO G

RA

FIC

O:

DA

TA:

TAV

OLA

:S

CA

LA:

+3

+2

+1

0-1-1

0+

1+

2+

3

TAVO

LA :

SE

15 S

CA

LA :

1:25

- 1

:10

ELA

BO

RAT

O G

RA

FIC

O :

NU

OVO

VA

NO

AS

CE

NO

RE

PIA

NTE

E P

AR

TIC

OLA

RI

DAT

A :

SE

TTE

MB

RE

201

6

Page 17: PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX …servizi.comune.fe.it/8071/attach/benimonumentali/docs/05... · 2016. 11. 4. · - uni en 1992-1-1:2005 - uni en 1993-1-1:2005

+2.2

6

HEA200

IPE2

00

HEA200

HEA200

+2.1

15 p

.s.f.

IPE1

60IP

E160

IPE1

60

IPE1

60IP

E160

IPE1

60

+4.2

4 p.

s.f.

+5.5

0 p.

s.f.

+6.7

6 p.

s.f.

+9.2

8 p.

s.f.

VIST

A FI

LOSc

ala

1:25

A

4083

2103

EF

G

-1.8

0

-1.9

0

PART

.2

CARP

LYsp

.25

mm

.

TRAV

ETTI

IN L

EGNO

8x12

cm

.IN

TERA

SSE

max

80

cm.

SE16 - NUOVO VANO ASCENSOREVISTA FILO A

VERI

FICA

REQU

OTA

ESIS

T.

PR

OG

ET

TO E

SE

CU

TIV

O D

I LA

BO

RA

TOR

IO A

PE

RTO

NE

LL’E

X-TE

ATR

O V

ER

DI

Mo

Ve.r

di-

Rid

ing

, Dev

elo

pm

ent,

Insp

irat

ion

ELA

BO

RA

TO G

RA

FIC

O:

DA

TA:

TAV

OLA

:S

CA

LA:

+3

+2

+1

0-1-1

0+

1+

2+

3

TAVO

LA :

SE

16 S

CA

LA :

1:2

5E

LAB

OR

ATO

GR

AFI

CO

: N

UO

VA V

AN

O A

SC

EN

OR

E V

ISTA

FIL

O A

DAT

A :

SE

TTE

MB

RE

201

6

Page 18: PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX …servizi.comune.fe.it/8071/attach/benimonumentali/docs/05... · 2016. 11. 4. · - uni en 1992-1-1:2005 - uni en 1993-1-1:2005

1'3

-1.8

0

-1.9

0

IPE2

00

+2.1

15 p

.s.f.

IPE1

60

+4.2

4 p.

s.f.

+5.5

0 p.

s.f.

+6.7

6 p.

s.f.

+8.0

2 p.

s.f.

+9.2

8 p.

s.f.

IPE1

60

IPE1

60

IPE1

60

IPE1

60

IPE1

60

IPE1

60

IPE1

60

IPE1

60

HEA200

HEA200

HEA200

TOND

O 20

TOND

O 20

340

137.5 65 137.5

40 65 40

190

50

PART

. 1Sc

ala

1:10

VIST

A FI

LOSc

ala

1:25

G

1825

IPE1

60

HEA200

PART

.1

PART

. 2Sc

ala

1:10

120

40 40 40

100 60

40

PIAT

TOsp

.10

mm

.

PIAT

TOsp

.10

mm

.

1'3

IPE2

00

+2.1

15 p

.s.f.

IPE1

60

+4.2

4 p.

s.f.

+5.5

0 p.

s.f.

+6.7

6 p.

s.f.

+8.0

2 p.

s.f.

+9.2

8 p.

s.f.

IPE1

60

IPE1

60

IPE1

60

IPE1

60

HEA200

HEA200

VIST

A FI

LOSc

ala

1:25

E

1825

PART

.1

IPE2

00

190819081964

1302 1302 1302107210721260126012601260

1260126012601260

SE17A - NUOVO VANO ASCENSOREVISTA FILI E PARTICOLARIE G

VERI

FICA

REQU

OTA

ESIS

T.

-1.8

0

-1.9

0VE

RIFI

CARE

QUOT

A ES

IST.

PR

OG

ET

TO E

SE

CU

TIV

O D

I LA

BO

RA

TOR

IO A

PE

RTO

NE

LL’E

X-TE

ATR

O V

ER

DI

Mo

Ve.r

di-

Rid

ing

, Dev

elo

pm

ent,

Insp

irat

ion

ELA

BO

RA

TO G

RA

FIC

O:

DA

TA:

TAV

OLA

:S

CA

LA:

+3

+2

+1

0-1-1

0+

1+

2+

3

TAVO

LA :

SE

17 S

CA

LA :

1:2

5 - 1

:10

ELA

BO

RAT

O G

RA

FIC

O :

NU

OVO

VA

NO

AS

CE

NO

RE

VIT

SA

FIL

I E, G

E P

AR

TIC

OLA

RI

DAT

A :

SE

TTE

MB

RE

201

6

Page 19: PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX …servizi.comune.fe.it/8071/attach/benimonumentali/docs/05... · 2016. 11. 4. · - uni en 1992-1-1:2005 - uni en 1993-1-1:2005

TRAVE PRINCIPALE 12x28

TRAVETTO12x14 i=80 max.

SOTTO PILASTRO12x24

SOTTO PILASTRO12x24

TRAVE 12x28PILASTRO PARAPETTO

12x24

+1.55

-0.20

-0.20

-0.20

STRALCIO PIANTASCALA 1:25

PILASTRI12x12

SE18A - SCALINATA IN LEGNODI ACCESSO ALLA TORRE SCENICAPIANTA

NOTA:• PER LE SEZIONI A-A, B-B e C-C SI RIMANDA ALLE TAVOLE

STRUTTURALI SE19, SE20, SE21

SOTTO PILASTRO12x24

SOTTO PILASTRO12x24

SOTTO PILASTRO12x24

PILASTRI12x12

TRAVETTO12x14

GIUNTO STRUTTURALEsp.10 cm.

800

MONTANTI PER PORTADI ACCESSO VANO SOTTOSCALA

PR

OG

ET

TO E

SE

CU

TIV

O D

I LA

BO

RA

TOR

IO A

PE

RTO

NE

LL’E

X-TE

ATR

O V

ER

DI

Mo

Ve.r

di-

Rid

ing

, Dev

elo

pm

ent,

Insp

irat

ion

ELA

BO

RA

TO G

RA

FIC

O:

DA

TA:

TAV

OLA

:S

CA

LA:

+3

+2

+1

0-1-1

0+

1+

2+

3

TAVO

LA :

SE

18 S

CA

LA :

1:2

5E

LAB

OR

ATO

GR

AFI

CO

: S

CA

LIN

ATA

IN L

EG

NO

DI A

CC

ES

SO

ALL

A T

OR

RE

SC

EN

ICA

PIA

NTA

DAT

A :

SE

TTE

MB

RE

201

6

Page 20: PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX …servizi.comune.fe.it/8071/attach/benimonumentali/docs/05... · 2016. 11. 4. · - uni en 1992-1-1:2005 - uni en 1993-1-1:2005

-1.80

-0.80

80 100 80

5050

7070

5050

340

260

2 TASSELLI M16TIPO "HILTI HIT200 CON HIV"

2+2 VITI DA LEGNO

4+4 VITI DA LEGNO

10

10

10

10

8

2+2 TASSELLI M16TIPO "HILTI HIT200 CON HIV"

200

10

8 244 8

150

TRAVE PRINCIPALE 12x28TRAVETTI SECONDARI12x14 i=80 max.

PILASTRO12x24

PILASTRO12x24

TRAVE 12x14

PILASTRO PARAPETTOD'ANGOLO 12x24

TRAVERSO12x12

TRAVERSO12x12

PILASTRO12x24

-0.20

PART.1PART.2

SEZIONE A-ASCALA 1:25

PART. 1SCALA 1:10

PART. 2SCALA 1:10

280

892

30039

2

50 100 50

8 184 8

9610

010

096

TRAVE IN LEGNO 12x28 i=100 cm6+6 VITIDA LEGNO Ø8

7070

7070

8

260

160 92 8

200

3+3 TASSELLI M16TIPO "HILTI HY200-A CON HIT-V"8

8

8 120 8

280

892

TRAVE PRINCIPALE 12x28

6+6 VITIDA LEGNO Ø8

80

~9900

CARPLYsp.25 mm.

SE19A - SCALINATA IN LEGNODI ACCESSO ALLA TORRE SCENICASEZIONE A-A

DIAGONALI DICONTROVENTO12x12 cm.

PR

OG

ET

TO E

SE

CU

TIV

O D

I LA

BO

RA

TOR

IO A

PE

RTO

NE

LL’E

X-TE

ATR

O V

ER

DI

Mo

Ve.r

di-

Rid

ing

, Dev

elo

pm

ent,

Insp

irat

ion

ELA

BO

RA

TO G

RA

FIC

O:

DA

TA:

TAV

OLA

:S

CA

LA:

+3

+2

+1

0-1-1

0+

1+

2+

3

TAVO

LA :

SE

19 S

CA

LA :

1:25

- 1:

10E

LAB

OR

ATO

GR

AFI

CO

: S

CA

LIN

ATA

IN L

EG

NO

DI A

CC

ES

SO

ALL

A T

OR

RE

SC

EN

ICA

SE

ZIO

NE

AA

DAT

A :

SE

TTE

MB

RE

201

6

Page 21: PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX …servizi.comune.fe.it/8071/attach/benimonumentali/docs/05... · 2016. 11. 4. · - uni en 1992-1-1:2005 - uni en 1993-1-1:2005

-1.80

-0.80TRAVE PRINCIPALE 12x28

TRAVETTI SECONDARI12x14 i=80 max.

PILASTRO12x24

PILASTRO12x24

TRAVETTO 12x14TRASVERSALE

TRAVE 12x28

PILASTRO PARAPETTO12x12

TRAVE SAGOMATA 12x28

PILASTRO12x24

TRAVE PRINCIPALE 12x28

1000

1750

600

-0.20

+1.552528

014

8528

012

80

SEZIONE B-BSCALA 1:25

SE20 - SCALINATA IN LEGNODI ACCESSO ALLA TORRE SCENICASEZIONE B-B

CARPLYsp.25 mm.

PART.1

PART.2

PR

OG

ET

TO E

SE

CU

TIV

O D

I LA

BO

RA

TOR

IO A

PE

RTO

NE

LL’E

X-TE

ATR

O V

ER

DI

Mo

Ve.r

di-

Rid

ing

, Dev

elo

pm

ent,

Insp

irat

ion

ELA

BO

RA

TO G

RA

FIC

O:

DA

TA:

TAV

OLA

:S

CA

LA:

+3

+2

+1

0-1-1

0+

1+

2+

3

TAVO

LA :

SE

20 S

CA

LA :

1:2

5E

LAB

OR

ATO

GR

AFI

CO

: S

CA

LIN

ATA

IN L

EG

NO

DI A

CC

ES

SO

ALL

A T

OR

RE

SC

EN

ICA

SE

ZIO

NE

BB

DAT

A :

SE

TTE

MB

RE

201

6

Page 22: PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX …servizi.comune.fe.it/8071/attach/benimonumentali/docs/05... · 2016. 11. 4. · - uni en 1992-1-1:2005 - uni en 1993-1-1:2005

SEZIONE C-CSCALA 1:25

SE21 - SCALINATA IN LEGNODI ACCESSO ALLA TORRE SCENICASEZIONE C-C

-1.80

-0.80TRAVE 12x28

PILASTRO12x24

600

-0.20

PART.2

CARPLYsp.40 mm.

TRAVE8x36 mm. TRAVE

12x36 mm.

TRAVE PRINCIPALE12x28 mm.

ELEMENTO IN LEGNODI FINITURA

PR

OG

ET

TO E

SE

CU

TIV

O D

I LA

BO

RA

TOR

IO A

PE

RTO

NE

LL’E

X-TE

ATR

O V

ER

DI

Mo

Ve.r

di-

Rid

ing

, Dev

elo

pm

ent,

Insp

irat

ion

ELA

BO

RA

TO G

RA

FIC

O:

DA

TA:

TAV

OLA

:S

CA

LA:

+3

+2

+1

0-1-1

0+

1+

2+

3

TAVO

LA :

SE

21 S

CA

LA :

1:2

5E

LAB

OR

ATO

GR

AFI

CO

: S

CA

LIN

ATA

IN L

EG

NO

DI A

CC

ES

SO

ALL

A T

OR

RE

SC

EN

ICA

SE

ZIO

NE

CC

DAT

A :

SE

TTE

MB

RE

201

6

Page 23: PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX …servizi.comune.fe.it/8071/attach/benimonumentali/docs/05... · 2016. 11. 4. · - uni en 1992-1-1:2005 - uni en 1993-1-1:2005

SE22 - STRUTTURA PORTANTEPARETE SCALA DI EMERGENZA

PROSPETTO ESTERNO PARETEScala 1:25

-1.80 q.p.f.-1.80 q.p.f.

-1.90-1.90

+3,30+3,301

+2.26+2.26

-1.80-1.80

-1.90-1.90

215(*)

(*) QUOTA DA VERIFICARECON PROGETTO

ARCHITETTONICO

STRUTTURA IN LEGNODI SOSTEGNO PANNELLI

DI TAMPONAMENTO

A

A

SEZIONE A-AScala 1:25

PART.1

215

PART. 1Scala 1:10

+3,30+3,30

IPE160

PIATTO sp.10 mm.SALDATO AL PROFILO IPE160E FISSATO ALLA STRUTTURA

IN LEGNO MEDIANTE OPPORTUNITASSELLI

STRUTTURA IN LEGNODI SOSTEGNO PANNELLI

DI TAMPONAMENTO

COLLEGAMENTOSUL MONTANTE

SALDATURAIN OFFICINA

VERIFICAREQUOTA ESIST.

VERIFICAREQUOTA ESIST.

VERIFICAREQUOTA ESIST.

PART.1

PR

OG

ET

TO E

SE

CU

TIV

O D

I LA

BO

RA

TOR

IO A

PE

RTO

NE

LL’E

X-TE

ATR

O V

ER

DI

Mo

Ve.r

di-

Rid

ing

, Dev

elo

pm

ent,

Insp

irat

ion

ELA

BO

RA

TO G

RA

FIC

O:

DA

TA:

TAV

OLA

:S

CA

LA:

+3

+2

+1

0-1-1

0+

1+

2+

3

TAVO

LA :

SE

22 S

CA

LA :

1:2

5 - 1

:10

ELA

BO

RAT

O G

RA

FIC

O :

STR

UTT

UR

A P

OR

TAN

TE P

AR

ETE

SC

ALA

DI E

ME

RG

EN

ZA

DAT

A :

SE

TTE

MB

RE

201

6


Recommended